Modeling of Buoyancy-Driven Natural Ventilation in Workshop: Optimization of Distance between Heat Source and Ground

2012 ◽  
Vol 170-173 ◽  
pp. 2579-2582 ◽  
Author(s):  
Ya Xin Su ◽  
A Long Su ◽  
Xin Wan

Natural ventilation is suitable for application to workshops with heat sources to keep good indoor air quality at lower energy cost. In this paper, the authors numerically investigated the buoyancy-driven natural ventilation in a workshop with heat source based on computational fluid dynamics (CFD) method. The effect of the distance between heat source and ground on the air flow and temperature distribution was examined. Results showed that the average air temperature at operation zone could be effectively reduced when the distance between heat source and ground increased. The temperature field in the upper zone of the workshop was improved by diminishing the hot air zone near the ceiling and the waste heat directly going into the operation zone decreased when the distance between heat source and ground increased.

2012 ◽  
Vol 446-449 ◽  
pp. 2904-2907
Author(s):  
Ya Xin Su ◽  
Xin Wan ◽  
A Long Su

The authors numerically simulated the natural ventilation in an industrial workshop with heat sources by computational fluid dynamics (CFD) method and the effect of skylight size on the indoor temperature, ventilation rate and air flow patterns inside the workshop was discussed in detail. Realizable k- turbulent model was used to calculate the flow. Results show that a larger skylight width improves the ventilation. The average air temperature at operation zone decreases and the waste heat directly going into the operation zone decreases when the skylight width increases. The ventilation rate increases very slightly when the skylight width increases from 6 meters to 9 meters, while it increases sharply when w exceeds 10 meters. When the skylight width increases, more hot air is exhausted and the higher temperature environment in the upper zone of the workshop is improved.


2011 ◽  
Vol 250-253 ◽  
pp. 3187-3190 ◽  
Author(s):  
Ya Xin Su ◽  
Xin Wan

The authors numerically simulated the natural ventilation in an industrial workshop with heat sources by computational fluid dynamics (CFD) method when the height of air inlet opening was set different values. The flow and temperature fields in the workshop were simulated by realizable k-e turbulent model combined with a Discrete Ordinate (DO) radiation. Results showed the height of air inlet opening strongly influenced the flow and temperature fields in the workshop. When the height of air inlet opening increased, the natural ventilation was improved and more fresh air flowed into the workshop. When the height of air inlet opening increased from 1.7 meters to 3 meters, the temperature in the operation zone of the workshop dropped. When the height of air inlet opening increased from 2.7 meters to 3.7 meters, the temperature in operation zone did not change much, while the temperature in the upper zone of the workshop dropped. The heat distribution factor decreased first with the height of air inlet opening and then increased again. When the height of air inlet opening was 3 meters, the heat distribution factor was minimal.


Author(s):  
M. F. Mohamed ◽  
M. Behnia ◽  
S. King ◽  
D. Prasad

Cross ventilation is a more effective ventilation strategy in comparison to single-sided ventilation. In the NSW Residential Flat Design Code1 (RFDC) the majority of apartments are required to adopt cross ventilation. However, in the case of studio and one-bedroom apartments, it is acknowledged that single-sided ventilation may prevail. Deep plan studio and one-bedroom apartments may achieve lower amenity of summer thermal comfort and indoor air quality where mechanical ventilation is not provided by air conditioning. Since compliance with the code may allow up to 40% of apartments in a development in Sydney to be single sided, it is important to understand the natural ventilation performance of such apartments. The objective of this paper is to investigate the natural ventilation potential in single-sided ventilated apartments to improve indoor air quality and thermal comfort. This investigation includes simulating various facade treatments involving multiple opening and balcony configurations. Balcony configurations are included in this study because, in Sydney, a balcony is a compulsory architectural element in any apartment building. The study uses computational fluid dynamics (CFD) software to simulate and predict the ventilation performance of each apartment configuration. This study suggests that properly configured balconies and openings can significantly improve indoor ventilation performance for enhanced indoor air quality and thermal comfort, by optimizing the available prevailing wind. However, it is important to note that inappropriately designed fac¸ade treatments also could diminish natural ventilation performance.


2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Fawaz Ghaleb Noman ◽  
Nazri Kamsah ◽  
Haslinda Mohamed Kamar

A combined natural ventilation and mechanical fans are commonly used to cool the interior space inside the mosques in Malaysia. This article presents a study on thermal comfort in the Al-Jawahir Mosque, located in Johor Bahru, Malaysia. The objective is to assess the thermal comfort inside the mosque under the present ventilation system by determining the Predicted Mean Vote (PMV) and the Predicted Percentage of Dissatisfied (PPD). These values were then compared to the limits stated in the ASHRAE Standard-55. It was found that the PMV varies from 1.68 to 2.26 while the PPD varies from 61% to 87%. These show that the condition inside the mosque is quite warm. Computational fluid dynamics (CFD) method was used to carry out flow simulations, to identify a suitable strategy to improve the thermal comfort inside the mosque. Results of CFD simulations show that installing four exhaust fans above the windows on the west-side wall of the mosque is the most effective strategy to improve the thermal comfort inside the mosque. Both the PMV and PPD values can potentially be reduced by more than 60%.


Author(s):  
Yan Long ◽  
Jinming Feng ◽  
Ke Liu ◽  
Shiping Jin ◽  
Yan Fu

In this paper, orthogonal test design method and the CFD method were used to study the different building envelopes, and the outdoor environment of natural ventilation effect of single span of high temperature industrial workshop. Firstly, 18 ventilation models of workshop with heat source were constructed with orthogonal test design. Secondly, 18 ventilation models of workshop with heat source were simulated with CFD method. Finally, the order of the influencing factors on the ventilation of workshop was obtained through multiple index range analysis of the orthogonal experiment results according to the average temperature inside the workshop. Then the optimal combination of the best ventilation effect was selected. The research results can provide effectively theoretical basis for the future industrial plant ventilation design and optimization.


2017 ◽  
Vol 14 (03) ◽  
pp. 1750021 ◽  
Author(s):  
A. Niktash ◽  
B. P. Huynh

A windcatcher is a structure for providing natural ventilation using wind power; it is usually fitted on the roof of a building to exhaust the inside stale air to the outside and supplies the outside fresh air into the building interior space working by pressure difference between outside and inside of the building. In this paper, the behavior of free wind flow through a three-dimensional room fitted with a centered position two-canal bottom shape windcatcher model is investigated numerically, using a commercial computational fluid dynamics (CFD) software package and LES (Large Eddy Simulation) CFD method. The results have been compared with the obtained results for the same model but using RANS (Reynolds Averaged Navier–Stokes) CFD method. The model with its surrounded space has been considered in both method. It is found that the achieved results for the model from LES method are in good agreement with RANS method’s results for the same model.


2010 ◽  
Vol 160-162 ◽  
pp. 280-286
Author(s):  
Ri Chao Liu ◽  
Zhong Hua Tang ◽  
Wei Yang Qi

This paper adopted computational fluid dynamics (CFD) method, used k-ε RNG turbulence model-closed control differential equations for numerical simulation. Through numerical simulation and analysis of wind environment in a middle school campus, the round wind field under dominant wind direction was got in the summer and winter. According to the results of velocity field and pressure field, analysis the wind environment, compared the influence of wind direction and surrounding buildings space to the natural ventilation, provided guidance introduce for the layout of the school.


Author(s):  
D. Y. Goswami ◽  
Gunnar Tamm ◽  
Sanjay Vijayaraghavan

A new thermodynamic cycle has been developed for the simultaneous production of power and cooling from low temperature heat sources. The proposed cycle combines the Rankine and absorption refrigeration cycles, providing power and cooling in desired ratios to best suit the application. A binary mixture of ammonia and water is used as the working fluid, providing a good thermal match with the sensible heat source over a range of boiling temperatures. Due to its low boiling point, the ammonia-rich vapor expands to refrigeration temperatures while work is extracted through the turbine. Absorption condensation of the vapor back into the bulk solution occurs near ambient temperatures. The proposed cycle is suitable as a bottoming cycle using waste heat from conventional power generation systems, or can utilize low temperature solar or geothermal renewable resources. The cycle can be scaled to residential, commercial or industrial uses, providing power as the primary goal while satisfying some of the cooling requirements of the application. The cycle is under both theoretical and experimental investigations. Initial parametric studies of how the cycle performs at various operating conditions showed the potential for the cycle to be optimized. Optimization studies performed over a range of heat source and heat sink temperatures showed that the cycle could be optimized for maximum work or cooling output, or for first or second law efficiencies. Depending on the heat source temperatures, as much as half of the output may be obtained as refrigeration under optimized conditions, with refrigeration temperatures as low as 205 K being achievable. Maximum second law efficiencies over 60% have been found with the heat source between 350 and 450 K. An experimental system was constructed to verify the theoretical results and to demonstrate the feasibility of the cycle. The investigation focused on the vapor generation and absorption processes, setting up for the power and refrigeration studies to come later. The turbine was simulated with an equivalent expansion process in this initial phase of testing. Results showed that the vapor generation and absorption processes work experimentally, over a range of operating conditions and in simulating the sources and sinks of interest. The potential for combined work and cooling output was evidenced in operating the system. Comparison to ideally simulated results verified that there are thermal and flow losses present, which were assessed to make both improvements in the experimental system and modifications in the simulations to include realistic losses.


Energies ◽  
2020 ◽  
Vol 13 (2) ◽  
pp. 370 ◽  
Author(s):  
Giovanni Manente ◽  
Mário Costa

The supercritical CO2 power cycle (s-CO2) is receiving much interest in the utilization of waste heat sources in the medium-to-high temperature range. The low compression work and highly regenerative layout result in high thermal efficiencies, even at moderate turbine inlet temperatures. The capability of heat extraction from the waste heat source is, however, limited because the heat input takes place over a limited temperature range close to the maximum cycle temperature. Accordingly, novel s-CO2 layouts have been recently proposed, aimed at increasing the heat extraction from the heat source while preserving as much as possible the inherently high thermal efficiency. Among these, the most promising ones feature dual expansion, dual recuperation, and partial heating. This work concentrates on the conceptual design of these novel s-CO2 layouts using a systematic approach based on the superimposition of elementary thermodynamic cycles. The overall structure of the single flow split with dual expansion (also called cascade), partial heating, and dual recuperated cycles is decomposed into elementary Brayton cycles to identify the building blocks for the achievement of a high performance in the utilization of waste heat sources. A thermodynamic optimization is set up to compare the performance of the three novel layouts for utilization of high temperature waste heat at 600 °C. The results show that the single flow split with a dual expansion cycle provides 3% and 15% more power compared to the partial heating and dual recuperated cycles, respectively, and 40% more power compared to the traditional single recuperated cycle used as the baseline. The separate evaluation of thermal efficiency and heat recovery effectiveness shows the main reasons behind the achievement of the highest performance, which are peculiar to each novel layout.


2012 ◽  
Vol 33 (3) ◽  
pp. 48-60
Author(s):  
Aleksandra Borsukiewicz-Gozdur

Abstract In the paper presented is an idea of organic Rankine cycle (ORC) operating with supercritical parameters and so called dry fluids. Discussed is one of the methods of improving the effectiveness of operation of supercritical cycle by application of internal regeneration of heat through the use of additional heat exchanger. The main objective of internal regenerator is to recover heat from the vapour leaving the turbine and its transfer to the liquid phase of working fluid after the circulation pump. In effect of application of the regenerative heat exchanger it is possible to obtain improved effectiveness of operation of the power plant, however, only in the case when the ORC plant is supplied from the so called sealed heat source. In the present paper presented is the discussion of heat sources and on the base of the case study of two heat sources, namely the rate of heat of thermal oil from the boiler and the rate of heat of hot air from the cooler of the clinkier from the cement production line having the same initial temperature of 260 oC, presented is the influence of the heat source on the justification of application of internal regeneration. In the paper presented are the calculations for the supercritical ORC power plant with R365mfc as a working fluid, accomplished has been exergy changes and exergy efficiency analysis with the view to select the most appropriate parameters of operation of the power plant for given parameters of the heat source.


Sign in / Sign up

Export Citation Format

Share Document