The Kinematics Mathematical Model of the Impulse Electro Flotation

2011 ◽  
Vol 403-408 ◽  
pp. 2936-2940
Author(s):  
Xiao Gang Deng ◽  
Xian Ming Zhang

Through the characteristics of the Impulse electro flotation Wastewater treatment equipment, the factors which affect the efficiency of this technology are analyzed. According to the Kinematical theory of flocculation process, the free particle flotation removal model is established used in the way how the steel ball model is simplified. , and the variable process of the concentration of the free particle along with the time is stimulated to be obtained. This mathematical model has the theoretical reason of how to choose the electric flotation parameters and design of the electric flotation treatment equipments. The result proves that when the treatment time is between 20 to 25 min., the removal rate of the free particles will achieve to above 90%, which is similar to the experiment data.

Author(s):  
Babak Soltani ◽  
Faramarz Hojati ◽  
Amir Daneshi ◽  
Bahman Azarhoushang

AbstractUnderstanding the laser ablation mechanism is highly essential to find the effect of different laser parameters on the quality of the laser ablation. A mathematical model was developed in the current investigation to calculate the material removal rate and ablation depth. Laser cuts were created on the workpiece with different laser scan speeds from 1 to 10 mm s−1 by an ultrashort pulse laser with a wavelength of about 1000 nm. The calculated depths of laser cuts were validated via practical experiments. The variation of the laser power intensity on the workpiece’s surface during laser radiation was also calculated. The mathematical model has determined the laser-material interaction mechanism for different laser intensities. The practical sublimation temperature and ablated material temperature during laser processing are other data that the model calculates. The results show that in laser power intensities (IL) higher than 1.5 × 109 W cm−2, the laser-material interaction is multiphoton ionisation with no effects of thermal reaction, while in lower values of IL, there are effects of thermal damages and HAZ adjacent to the laser cut. The angle of incidence is an essential factor in altering incident IL on the surface of the workpiece during laser processing, which changes with increasing depth of the laser cut.


2007 ◽  
Vol 359-360 ◽  
pp. 384-388
Author(s):  
Feng Jun Chen ◽  
Shao Hui Yin ◽  
Jian Wu Yu ◽  
Hitoshi Ohmori ◽  
Wei Min Lin ◽  
...  

According to the sharp rheological characteristics of magnetorheological fluid in the magnetic field, the principle and mechanism of magnetorheological finishing is analyzed. Based on the Preston equation, the Reynolds equation and its boundary conditions, the two-dimensional material removal model is built and simulated. Furthermore, a series of MRF experiments are carried out, and the influence of the immersed depth and material kinds on material removal rate are clarified respectively. The experimental results are compared with the modeling results of material removal rate to confirm the mechanistic model validity.


2008 ◽  
Vol 53-54 ◽  
pp. 155-160 ◽  
Author(s):  
Qiu Sheng Yan ◽  
Ai Jun Tang ◽  
Jia Bin Lu ◽  
Wei Qiang Gao

A new plate polishing technique with an instantaneous tiny-grinding wheel cluster based on the magnetorheological (MR) effect is presented in this paper, and some experiments were conducted to prove its effectiveness and applicability. Under certain experimental condition, the material removal rate was improved by a factor of 20.84% as compared with the conventional polishing methods with dissociative abrasive particles, while the surface roughness of the workpiece was not obviously increased. Furthermore, the composite of the MR fluid was optimized to obtain the best polishing performance. On the basis of the experimental results, the material removal model of the new plate polishing technique was presented.


2014 ◽  
Vol 926-930 ◽  
pp. 4361-4364
Author(s):  
Xiao Qiao Song

When straw pulp papermaking wastewater was treated by the process of coagu-flocculation and nuclear-flocculation, there were still high CODCr. UV254 can reflect organic pollutants and organic pollutants of unsaturated aromatic ring, carbon-carbon double bond. With the decrease of molecular weight of organic pollutants, absorption of ultraviolet light will decrease. Indirectly, it reflectd that the combination process had a good removal effect on high molecular aromatic hydrocarbons difficult to be biodegraded. Meanwhile it can improve the the biodegradability. It used the activated sludge process as subsequent process of coagulation and-flocculation process. The test results showed that the removal rate of CODCr was 24.1%, CODCr was the 88.1mg/L. It reached effluent standard.


Author(s):  
Pravin R. Lokhande ◽  
S. Balaguru

The aim of this article is to develop the mathematical model to describe response of endodontic file in curved root canal during the preparation of root canal using fracture mechanics approach. Any obturation process involves the filling of prepared root canal using bio-compatible materials like gutta-percha. During preparation of infected root canal, substrate, dead tissue and pulp is removed and tapered shape is formed so that any practitioner can fill it effectively. During preparation process of root canal, the canal wall applies locking action and causes resistance to motion of endodontic file, finally resulting into fatigue failure. This article described plastic behavior of endodontic file in curved root canal, mathematical model describing the necessary condition for crack growth in endodontic file, a mathematical model describing plastic zone size for crack on surface of endodontic file, a mathematical model describing crack tip opening displacement for crack on surface of endodontic file and mathematical model for pure-combined torsion and bending consideration for design of endodontic file. The mathematical model described is helpful for the Endodontic experts, researchers, design engineers. However the applicability of the described mathematical model limited to assumption of study. The gap between root canal to be prepared and endodontic file is zero while preparation. The endodontic file weight, speed of rotation and substrate removal rate is assumed to be constant. The mathematical model for endodontic file discussed above proved to be efficient tool for studying the root canal preparation.


2014 ◽  
Vol 955-959 ◽  
pp. 2294-2299 ◽  
Author(s):  
Hui Ling Du ◽  
Bao Yuan Pan ◽  
Jing Li

The RO concentrate containing non-degradation organic pollutants was treated by electro-Fenton process. The high voltage pulse generator was used as discharge power. The effects of pulsed electric field parameters, aeration rate and pH on COD removal rate was investigated. The results indicate that the COD removal rate is up to 80.71% when pulsed voltage, pulsed frequency, treatment time, aeration rate and pH are 30000 V, 5 Hz, 240 s, 1.0 m3/h and 10, respectively.


2011 ◽  
Vol 63-64 ◽  
pp. 719-722
Author(s):  
Jian Ye Guo ◽  
Chao Yu ◽  
Guang Qi Cai

This paper took the grinding force in the heavy load honing as the object to research, it mainly analyzed the influence of the grinding force to the material removal rate. First the mathematical model of grinding force was established from starting with the honing pressure. Then the mathematical model of material removal rate was established according to the relationship between material removal volume and honing pressure. Finally the influence of the honing pressure to the material removal rate was analyzed with the aid of software. The results of this paper have important theoretical significance to optimize the processing technology of heavy load honing and further enhance the machining precision and the honing efficiency.


2015 ◽  
Vol 11 (3) ◽  
pp. 372-385 ◽  
Author(s):  
M. P. Jenarthanan ◽  
A Ram Prakash ◽  
R Jeyapaul

Purpose – The purpose of this paper is to develop a mathematical model for optimizing the metal removal rate (MRR) through Response Surface Methodology (RSM). The developed model helps us to analyze the influence of individual input machining parameters (cutting speed, feed rate, weight percentage) on the responses in machining of Al-TiB2 composite. Design/methodology/approach – RSM is used to optimize the MRR by developing a mathematical model. Three factors, three-level box Behnken design matrix in RSM is employed to carry out the experimental investigation. The “Design Expert 8.0” software is used for regression and graphical analysis of the data are collected. The optimum values of the selected variables are obtained by solving the regression equation and by analyzing the response surface contour plots. Analysis of variance (ANOVA) is applied to check the validity of the model and for finding the significant parameters. Findings – The response surface model developed, helps to calculate the MRR at different input cutting parameters with the chosen range with more than 95 per cent confidence intervals. Originality/value – The effect of machining parameters on MRR during machining of Al-TiB2 composites using RSM has not been previously analyzed.


2013 ◽  
Vol 284-287 ◽  
pp. 2778-2783 ◽  
Author(s):  
Ying Chien Tsai ◽  
Guang Miao Huang ◽  
Jun Hong Chen ◽  
Shih Wei Chen

The concentricity of the optical fiber micro lens affects the coupling efficiency of a laser module a lot. In this paper, the effect of the perpendicularity of the broken edge on the concentricity of the micro optical fiber end-face during the micro polishing process is studied. A mathematical model is derived to describe the variation of the material removal rate (MRR) when the tilt angles and amount of feed of the optical fiber are changed. An experiment is built to measure the concentricity of optical fiber with different tilt angles and feeds. The result shows that both of the dimensionless factor QAB and measured concentricity have the same tendency. The concentricity is better when the tilt angle is smaller and the amount of feed is larger. An improved polishing process is suggested. A good concentricity within 1μm can be achieved when fabricate the double-variable curvatures end-face of the optical fiber.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Tadashi Tomo ◽  
Maria Larkina ◽  
Ayumi Shintani ◽  
Tomonari Ogawa ◽  
Bruce M. Robinson ◽  
...  

Abstract Background The Japanese Society for Dialysis Therapy (JSDT) published in 2013 inaugural hemodialysis (HD) guidelines. Specific targets include 1.4 for single-pool Kt/V (spKt/V) with a minimum dose of 1.2, minimum dialysis session length of 4 hours, minimum blood flow rate (BFR) of 200 mL/min, fluid removal rate no more than 15 mL/kg/hr, and hemodiafiltration (HDF) therapy for certain identified symptoms. We evaluated the effect of these guidelines on actual practice in the years spanning 2005 – 2018. Methods Analyses were carried out to describe trends in the above HD prescription practices from December 2005 to April 2013 (before guideline publication) to August 2018 based on prevalent patient cross-sections from approximately 60 randomly selected HD facilities participating in the Japan Dialysis Outcomes and Practice Patterns Study. Results From April 2006 to August 2017 continual rises occurred in mean spKt/V (from 1.35 to 1.49), and percent of patients having spKt/V>1.2 (71% to 85%). Mean BFR increased with time from 198.3 mL/min (April 2006) to 218.4 mL/min (August 2017) , along with percent of patients with BFR >200 ml/min (65% to 85%). HDF use increased slightly from 6% (April 2006 and August 2009) to 8% by April 2013, but increased greatly thereafter to 23% by August 2017. In contrast, mean HD treatment time showed little change from 2006-2017, whereas mean UFR declined from 11.3 in 2006 to 8.4 mL/Kg/hour in 2017. Conclusions From 2006 – 2018 Japanese HD patients experienced marked improvement in reaching the spKt/V target specified by the 2013 JSDT guidelines. This may have been due to moderate increase in mean BFR even though mean HD session length did not change much. In addition, HDF use increased dramatically in this time period. Other HD delivery changes during this time, such as increased use of super high flux dialyzers, also merit study. While we cannot definitively conclude a causal relationship between the publication of the guidelines and the subsequent practice changes in Japan, those changes moved practice closer to the recommendations of the guidelines.


Sign in / Sign up

Export Citation Format

Share Document