UIR-Scanner Potential to Defect Detection in Concrete

2013 ◽  
Vol 687 ◽  
pp. 359-365 ◽  
Author(s):  
Andrzej Garbacz ◽  
Tomasz Piotrowski ◽  
Kamil Zalegowski ◽  
Grzegorz Adamczewski

In the research three NDT methods: indirect Ultrasonic Pulse Velocity, Impact-Echo (IE) and Ground Penetrating Radar (GPR) were used for investigation of concrete slabs with well-defined reinforcement and artificial defects. The obtained results shows the big potential of combination of UPE, IE and GPR methods for detection of wide range of defects in concrete structures. These methods were implemented for UIR scanner development – NDT system which accelerate assessment of concrete structure. Moreover, when the result of one method is not clear and individually the method seems to be not effective, the data from the other one allows for proper interpretation of concrete integrity.

2018 ◽  
Vol 219 ◽  
pp. 03003
Author(s):  
Richard Dvořák ◽  
Zdeněk Chobola ◽  
Ivo Kusák

The paper is focused on non-destructive measurement of high temperature degraded concrete test specimens of three mixtures different by the use of coarse aggregate. Testing is done by ultrasonicpulse velocitymethod and Impact-Echo method. Non-destructive results are compared with destructive tests. Ultrasonic pulse velocity, dominant resonance frequency and acoustic impedance are discussed and compared with changes in density, cubic compressive strength, and tensile strength of concrete. The paper suggests possible assessment of degraded concrete by the change in acoustic impedance dependent on residual tensile strength.


2018 ◽  
Vol 196 ◽  
pp. 02045
Author(s):  
Andrzej Moczko ◽  
Marta Moczko

The paper presents overview of European standard procedures related to determining concrete quality basing on the in-situ testing. Among other things following testing methods have been discussed: testing cored specimens, rebound measurements, “pull-out” method, “pull-off” method, ultrasonic pulse velocity measurements. Testing conditions, guidelines for calibration and crucial requirement for proper interpretation of the data obtained by means of rebound and ultrasonic measurements were shown. Independently “pull-out” and “pull-off” NDT methods have been introduced. Finally, the European procedures of assessment of in-situ concrete compressive strength in structures have been also presented.


2011 ◽  
Vol 250-253 ◽  
pp. 1025-1030
Author(s):  
Yi Ching Lin ◽  
Yung Chiang Lin ◽  
Yu Feng Lin

This paper investigates the feasibility of using the P-wave velocity measured by the impact-echo technique to estimate the strength of hardened self-consolidating concrete. The relationship between the through-transmission ultrasonic pulse velocity (UPV) and the strength of high performance concrete was established previously by performing experimental studies on water-cured cylinders made of concrete having variations in water-cementitious amterial ratio and aggregate content. However, the through-transmission UPV measurement is not applicable to concrete elements with only one accessible surface. In this paper, two plate-like specimens were made of self-consolidating concrete and they had different curing conditions. One specimen was immersed in water and the other was covered with wet gunny sack for 7 days. The impact-echo technique, one-sided wave velocity measurement technique, is adopted to determine the P-wave velocity of the plate-like concrete specimens at an age of 28 days. The difference between the impact-echo P-wave velocity (IE-PV) and the through-transmission ultrasonic pulse velocity (UPV) is studied. In addition, the measured IE-PV is used to estimate the strength of the plate-like concrete specimen and the estimated strength is verified by taking cores from the specimen.


Author(s):  
Aref Shafiei ◽  
Kyle A. Riding ◽  
Robert J. Peterman ◽  
Chris Christensen ◽  
B. Terry Beck ◽  
...  

Concrete railroad ties have been used in increasing numbers in the U.S., particularly in high-speed rail, heavy-haul freight lines, and new track construction because of their reduced deflections, durability, and competitive cost. In-track assessment of concrete railroad ties can be a challenge, however because many exterior tie surfaces are covered by tie pads and rail or ballast. This damage may include concrete section wear from abrasion, cracking, or crumbling, or other types of defects. Damage internal to the concrete can also not be seen visually. The time and cost needed to inspect these tie surfaces means that it is not routinely performed. Non-destructive testing offers promise as a way to assess concrete tie integrity without having to remove ballast, however more information is needed to know how well non-destructive techniques work in detecting damage. Two of the most promising techniques for investigating the integrity of concrete non-destructively are ultrasonic pulse velocity and impact-echo. Ultrasonic pulse velocity (UPV) and Impact-echo (IE) were applied to investigate the uniformity of concrete railroad tie and its cavities, cracks and defects for concrete ties taken from track after service. This paper evaluated the variability of the test results in UPV and IE testing condition in which two concrete railroad ties with same manufacture and load history condition were tested in both methods. Two additional concrete ties with the same manufacture and load history as each other with visible longitudinal cracks were also examined to see how the damage affected the variability measured. For this purpose, wave pulse for every full length tie from full top, half top, longitude and two sides were measured using ultrasonic pulse (ASTM C597). Also, thickness of concrete ties on both sides, including rail seat location and the middle were assessed by standard tests method for measuring the p-wave speed and the thickness of concrete using the impact-echo method (ASTM C1383). Advice is given on how to interpret ultrasonic pulse velocity and impact-echo measurements and given the variability of the test method how to flag ties for potential deterioration given that most ties in service will not have initial measurements taken before damage for comparison.


2013 ◽  
Vol 12 (3) ◽  
Author(s):  
Sudarmadi Sudarmadi

In this paper a case study about concrete strength assessment of bridge structure experiencing fire is discussed. Assessment methods include activities of visual inspection, concrete testing by Hammer Test, Ultrasonic Pulse Velocity Test, and Core Test. Then, test results are compared with the requirement of RSNI T-12-2004. Test results show that surface concrete at the location of fire deteriorates so that its quality is decreased into the category of Very Poor with ultrasonic pulse velocity ranges between 1,14 – 1,74 km/s. From test results also it can be known that concrete compressive strength of inner part of bridge pier ranges about 267 – 274 kg/cm2 and concrete compressive strength of beam and plate experiencing fire directly is about 173 kg/cm2 and 159 kg/cm2. It can be concluded that surface concrete strength at the location of fire does not meet the requirement of RSNI T-12-2004. So, repair on surface concrete of pier, beam, and plate at the location of fire is required.


2021 ◽  
Vol 11 (9) ◽  
pp. 3747
Author(s):  
Leticia Presa ◽  
Jorge L. Costafreda ◽  
Domingo Alfonso Martín

This work aims to study the relationship between the compression resistance and velocity from ultrasonic pulses in samples of mortars with 25% of pozzolanic content. Pozzolanic cement is a low-priced sustainable material that can reduce costs and CO2 emissions that are produced in the manufacturing of cement from the calcination of calcium carbonate. Using ultrasonic pulse velocity (UPV) to estimate the compressive resistance of mortars with pozzolanic content reduces costs when evaluating the quality of structures built with this material since it is not required to perform an unconfined compression test. The objective of this study is to establish a correlation in order to estimate the compression resistance of this material from its ultrasonic pulse velocity. For this purpose, we studied a total of 16 cement samples, including those with additions of pozzolanic content with different compositions and a sample without any additions. The results obtained show the mentioned correlation, which establishes a basis for research with a higher number of samples to ascertain if it holds true at greater curing ages.


Sign in / Sign up

Export Citation Format

Share Document