Simultaneous Determination of Oleanolic Acid and Ursolic Acid in Leaves of Paulownia by HPLC

2013 ◽  
Vol 781-784 ◽  
pp. 787-791 ◽  
Author(s):  
Ya Li Xing ◽  
Liang Wu Bi ◽  
Zhen Dong Zhao ◽  
Tian Juan Xia

A quick and accurate HPLC method has been developed for the simultaneous quantification of two bioactive triterpenes, ursolic acid and oleanolic acid in Paulownia leaves. The samples were analyzed on a Shim-pack ODS-CLC (M) (4.6 mm × 250 mm, 5 μm) column kept at 21 °C, using the methanol and aqueous phase containing 0.05%phosphoric acid with the volumetric ratio of 91.7:8.3 as the mobile phase at a flow rate of 0.6 mL/ min, and the detection wavelength was set at 210 nm. The method was validated and applied to the simultaneous quantification of the two triterpenes in Paulownia leaf extract. The standard curves were established in the range of 0.44 ~ 8.75 μg for oleanolic acid and 0.92 ~ 18.37 μg for ursolic acid. The contents of oleanolic acid and ursolic acid in leaves of Paulownia were determinated using the HPLC method and the contents were 3.87 mg/g and 13.61 mg/g, respectively.

2011 ◽  
Vol 94 (1) ◽  
pp. 106-109 ◽  
Author(s):  
Suryakant D Bhosale ◽  
Sadhana J Rajput

Abstract An RP-HPLC method has been developed for the simultaneous determination of butenafine hydrochloride and betamethasone dipropionate on an Inertsil C18 column (250×4.6 mm id) using a mobile phase gradient consisting of methanol and water at a flow rate of 1 mL/min. Detection was carried out at 254 nm. Retention times of betamethasone dipropionate and butenafine hydrochloride were 4.82 (±0.80) and 16.18 (±0.17) min, respectively. The method was validated with respect to specificity, linearity, accuracy, precision, ruggedness, and robustness. This method is simple, precise, and sensitive, and applicable for the simultaneous quantification of butenafine hydrochloride and betamethasone dipropionate in a cream formulation.


2013 ◽  
Vol 96 (1) ◽  
pp. 56-59 ◽  
Author(s):  
Agha Zeeshan Mirza ◽  
M Saeed Arayne ◽  
Najma Sultana

Abstract The objective of this research was to develop and validate a rapid, economical, and sensitive HPLC method for quantitative determination of gliquidone, pioglitazone hydrochloride, and atorvastatin in tablets and serum. Due to drug combination of these formulations, there has been a need for a reliable quantitative method to determine these drugs in commercial samples and human serum. The chromatographic separation was carried out at ambient temperature with a mobile phase consisting of methanol–water (90 + 10, v/v), with pH adjusted to 3.50 with phosphoric acid. The pump was operated at a flow rate of 1 mL/min, and all analytes were detected at 235 nm. The method was linear over the concentration range of 5–50 μg/mL for all the drugs. The LOD of gliquidone, pioglitazone hydrochloride, and atorvastatin was 0.30, 1.30, and 0.57 μg/mL and LOQ was 0.98, 4.28, and 1.90 μg/mL, respectively. The proposed method was successfully applied to the determination of these drugs in commercial tablets and human serum. The established method was validated with respect to specificity, linearity, precision, accuracy, and ruggedness.


2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Bürge Aşçı ◽  
Şule Dinç Zor ◽  
Özlem Aksu Dönmez

Box-Behnken design was applied to optimize high performance liquid chromatography (HPLC) conditions for the simultaneous determination of potassium sorbate, sodium benzoate, carmoisine, allura red, ponceau 4R, and caffeine in commercial soft drinks. The experimental variables chosen were pH (6.0–7.0), flow rate (1.0–1.4 mL/min), and mobile phase ratio (85–95% acetate buffer). Resolution values of all peak pairs were used as a response. Stationary phase was Inertsil OctaDecylSilane- (ODS-) 3V reverse phase column (250 × 4.6 mm, 5 μm) dimensions. The detection was performed at 230 nm. Optimal values were found 6.0 pH, 1.0 mL/min flow rate, and 95% mobile phase ratio for the method which was validated by calculating the linearity (r2>0.9962), accuracy (recoveries ≥ 95.75%), precision (intraday variation ≤ 1.923%, interday variation ≤ 1.950%), limits of detection (LODs), and limits of quantification (LOQs) parameters. LODs and LOQs for analytes were in the range of 0.10–0.19 μg/mL and 0.33–0.63 μg/mL, respectively. The proposed method was applied successfully for the simultaneous determination of the mixtures of five food additives and caffeine in soft drinks.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Hina Shamshad ◽  
Agha Zeeshan Mirza

Abstract Background Present work describes a fast, simple, and sensitive procedure for the simultaneous determination of cetirizine in the presence of quinolones using diclofenac sodium as an internal standard. The present work was designed to analyze these compounds in pharmaceutical and clinical labs being economical for use. Results The mobile phase consisted of the simple composition of methanol, acetonitrile, and water in a ratio of 50:20:30 with a pH adjusted to 3.1 at a flow rate of 1 mL min−1. The UV detection was performed at 225 nm. The linearity was assessed over the range of 2.5–50 μg mL−1 for all drugs. The parameters such as accuracy, precision, linearity (>0.999), and sensitivity were satisfactory. Conclusion The method was equally applicable for formulation and human serum with recovery values between 95 and 105%. The results of the method were validated statistically according to ICH guidelines.


Author(s):  
Hong Ngoc Nguyen Thi ◽  
Thanh Hoa Mac Thi ◽  
Thanh An Vu Thi ◽  
Thanh Ha Pham Thi ◽  
Khanh Cao Cong ◽  
...  

A HPLC method has been validated for simultaneous determination of Alpha-lactalbumin (α- LA) and Beta- lactoglobulin (β-LG) contents in dietary supplements by HPLC-PDA. The method was carried out in C18 column with a gradient of 0.1% TFA/ water – 0.1% TFA/ acetonitrile as mobile phase. The proteins were detected at 215 nm wavelength within 50 minutes. The method was validated in specificity, linearity, precision and accuracy; and then was applied to analyze several random dietary supplements.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Leilei Guo ◽  
Xiangqin Tian ◽  
Shangran Shan ◽  
Jian Han ◽  
Xiaojun Shang ◽  
...  

A RP-HPLC-UV method was developed and validated for simultaneous determination of florfenicol and diclazuril in compound powder. The separation involved using a SinoChoom ODS-BP C18(5 μm, 4.6 mm × 250 mm) analytical column. The mobile phase was a mixture of acetonitrile-0.2% phosphoric acid (pH was adjusted to 3.0 with triethylamine). The ratio of acetonitrile and 0.2% phosphoric acid in the mobile phase was 60 : 40 (v/v) from 0 minutes to 6 minutes and 70 : 30 (v/v) from 6.1 minutes to 15 minutes. The flow rate was 1 mL/min. The temperature of the analytical column was maintained at 30°C. The detection was monitored at 225 nm and 277 nm for florfenicol and diclazuril, respectively. The excipients in the compound powder did not interfere with the drug peaks. The calibration curves of florfenicol and diclazuril were fairly linear over the concentration ranges between 50.0–500.0 μg/mL (r=0.9995) and 10.0–100.0 μg/mL (r=0.9992), respectively. The RSD of both the intraday and interday variations was below 2.1% for florfenicol and diclazuril. The method was successfully validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of florfenicol and diclazuril in compound powder.


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Yu Zhou ◽  
Wu Ling Wei ◽  
Jiang Xing Hua ◽  
Qingsheng Fan

A simple, rapid, and specific HPLC method was established for simultaneous determination of five major lignans (Schizandrol A,Schizandrol B,Schisandrin A,γ-Schisandrin, andSchisandrin C) inSchisandra chinensis. The five lignans can be separated completely on Kromasil C18column (250 nm × 4.6 nm) and then detected at 254 nm using methanol (mobile phase A) and water (mobile phase B) with gradient elution as the mobile phase at 1.0 mL/min flow rate. The column temperature was 30°C. The method was validated in terms of linearity, precision, stability, repeatability, and recovery. Results showed that the method is accurate and reproducible.


Separations ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 5
Author(s):  
Mohd Afzal ◽  
Mohd. Muddassir ◽  
Abdullah Alarifi ◽  
Mohammed Tahir Ansari

A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.


2011 ◽  
Vol 8 (1) ◽  
pp. 340-346 ◽  
Author(s):  
Rajesh M. Kashid ◽  
Santosh G. Singh ◽  
Shrawan Singh

A reversed phase HPLC method that allows the separation and simultaneous determination of the preservatives methyl paraben (M.P.) and propyl paraben (P.P.) is described. The separations were effected by using an initial mobile phase of water: acetonitrile (50:50) on Inertsil C18 to elute P.P. and M.P. The detector wavelength was set at 205 nm. Under these conditions, separation of the two components was achieved in less than 10 min. Analytical characteristics of the separation such as precision, specificity, linear range and reproducibility were evaluated. The developed method was applied for the determination of preservative M.P. and P.P. at concentration of 0.01 mg/mL and 0.1 mg/mL respectively. The method was successfully used for determining both compounds in sucralfate suspension.


2006 ◽  
Vol 3 (1) ◽  
pp. 60-64 ◽  
Author(s):  
P. Venkata Reddy ◽  
B. Sudha Rani ◽  
G. Srinu Babu ◽  
J. V. L. N. Seshagiri Rao

A reverse phase HPLC method is developed for the determination of Raloxifene in pharmaceutical dosage forms. Chromatography was carried out on an inertsil C18 column using a mixture of acetonitrile and phosphate buffer (30:70 v/v) as the mobile phase at a flow rate of 1 mL/min. Detection was carried out at 290 nm .The retention time of the drug was 10.609 min. The method produced linear responses in the concentration range of 0.5-200 µg/mL of Raloxifene. The method was found to be applicable for determination of the drug in tablets.