Properties of High Strength Concrete with Calcined Diatomaceous Earth as Cement Replacement under Compression

2020 ◽  
Vol 402 ◽  
pp. 7-13
Author(s):  
Muttaqin Hasan ◽  
Aris Muyasir ◽  
Taufiq Saidi ◽  
Husaini ◽  
Raudha Azzahra

In this research, calcined diatomaceous earth from Aceh Besar, Indonesia was used as cement replacement in producing high strength concrete. Four concrete mixtures in which the percentage of cement replacement of 0%, 5%, 10% and 15% by weight were studied. Four cylinder-specimens with 100 mm diameter and 200 mm high were prepared for each mixture. The compression load was applied on the specimens at the age of 28 days until the specimens failed. The mixture without calcined diatomaceous earth was more workable than that with diatomaceous earth. The compressive strength of concrete with diatomaceous earth in this study was almost the same for all mixture. However, those compressive strength was lower than the compressive strength of concrete without calcined diatomaceous earth for about 14.6%. Modulus of elasticity of high strength concrete decreased with increasing of cement replacement percentage.

2018 ◽  
Vol 20 (2) ◽  
pp. 65-70
Author(s):  
Endah Kanti Pangestuti ◽  
Sri Handayani ◽  
Mego Purnomo ◽  
Desi Christine Silitonga ◽  
M. Hilmy Fathoni

Abstract. The use of coal waste (Fly Ash) is currently being developed in building materials technology, as a high-strength concrete mix material. This study aims to determine the strength of concrete by adding fly ash as a substitute for cement in high-strength concrete mixtures. This research was conducted with an experimental method to obtain results and data that would confirm the variables studied. The total number of specimens used in this study were 36 pieces with different sizes of cube tests which were 15 cm x 15 cm x 15 cm. A total of 36 concrete samples were used to test the compressive strength of concrete with a percentage of Fly Ash in  0% (normal concrete), 20%, 25% and 30% with a concrete treatment age of 7 days, 21 days and 28 days. A total of 12 more samples were used to test water absorption in concrete at 28 days of maintenance. Each percentage percentage of Fly Ash uses 3 concrete test samples. The increase in compressive strength occurs at 7, 21 and 28 days in concrete. However, the compressive strength of concrete produced by concrete using the percentage of Fly Ash is always lower than the value of normal concrete compressive strength. From testing the compressive strength of concrete at 28 days of treatment with content of 0%, 20%, 25% and 30% Fly Ash obtained results of 45.87 MPa, 42.67 MPa, 40.89 MPa, and 35.27 MPa respectively


2010 ◽  
Vol 163-167 ◽  
pp. 1655-1660
Author(s):  
Jian Zhang ◽  
Bo Diao ◽  
Xiao Ning Zheng ◽  
Yan Dong Li

The mechanical properties of high strength concrete(HSC) were experimentally investigated under mixed erosion and freeze-thaw cycling according to ASTM C666(Procedure B), the erosion solution was mixed by weight of 3% sodium chloride and 5% sodium sulfate. The mass loss, relative dynamic modulus of elasticity, compressive strength, elastic modulus and other relative data were measured. The results showed that with the increasing number of freeze-thaw cycles, the surface scaled more seriously; the mass loss, compressive strength and elastic modulus continued to decrease; the relative dynamic modulus of elasticity increased slightly in the first 225 freeze-thaw cycles, then decreased in the following 75 cycles; the corresponding strain to peak stress decreased with the increase of freeze-thaw cycles. After 200 cycles, the rate of deterioration of concrete accelerated obviously.


2010 ◽  
Vol 163-167 ◽  
pp. 1321-1324
Author(s):  
Sang A. Cha ◽  
Cho Hwa Moon ◽  
Sang Woo Kim ◽  
Kil Hee Kim ◽  
Jung Yoon Lee

The number of high-rise reinforced concrete (RC) buildings is steadily increasing since 1980’s. The use of high strength concrete is indispensible for high-rise RC construction to ensure sufficient strength of the structure. The effect of high strength concrete can be significantly improved by the use of high strength and large size reinforcing bars. The yield strength of transverse reinforcement is limited in the current design codes to prevent possible sudden concrete failure due to over reinforcement. This paper presents the effects of the yield strength of transverse reinforcement and compressive strength of concrete on the structural behavior of reinforced concrete cylinders. Two parameters were considered in this investigation: compressive strength of concrete and the yield strength of transverse reinforcement (472MPa, 880MPa, and 1,430 MPa). Analytical and experimental results indicated that the structural behavior of RC cylinders confined with high strength transverse reinforcement is strongly influenced by compressive strength of concrete.


Materials ◽  
2019 ◽  
Vol 12 (5) ◽  
pp. 822 ◽  
Author(s):  
Farhad Aslani ◽  
Fatemeh Hamidi ◽  
Qilong Ma

In this study, the fresh and hardened state properties of heavyweight self-compacting concrete (HWSCC) and heavyweight high strength concrete (HWHSC) containing heavyweight magnetite aggregate with 50, 75, and 100% replacement ratio, and their performance at elevated temperatures were explored experimentally. For fresh-state properties, the flowability and passing ability of HWSCCs were assessed by using slump flow, T500 mm, and J-ring tests. Hardened-state properties including hardened density, compressive strength, and modulus of elasticity were evaluated after 28 days of mixing. High-temperature tests were also performed to study the mass loss, spalling of HWSCC and HWHSC, and residual mechanical properties at 100, 300, 600 and 900 °C with a heating rate of 5 °C/min. Ultimately, by using the experimental data, rational numerical models were established to predict the compressive strength and modulus of elasticity of HWSCC at elevated temperatures. The results of the flowability and passing ability revealed that the addition of magnetite aggregate would not deteriorate the workability of HWSCCs and they retained their self-compacting characteristics. Based on the hardened densities, only self-compacting concrete (SCC) with 100% magnetite content, and high strength concrete (HSC) with 75 and 100% magnetite aggregate can be considered as HWC. For both the compressive strength and elastic modulus, decreasing trends were observed by introducing magnetite aggregate to SCC and HSC at an ambient temperature. Mass loss and spalling evaluations showed severe crack propagation for SCC without magnetite aggregate while SCCs containing magnetite aggregate preserved up to 900 °C. Nevertheless, the mass loss of SCCs containing 75 and 100% magnetite content were higher than that of SCC without magnetite. Due to the pressure build-up, HSCs with and without magnetite showed explosive spalling at high temperatures. The residual mechanical properties analysis indicated that the highest retention of the compressive strength and modulus of elasticity after exposure to elevated temperatures belonged to HWSCC with 100% magnetite content.


Author(s):  
Rao Krishna ◽  
Rathish Kumar ◽  
B. Srinivas

Concrete is a versatile material with tremendous applications in civil engineering construction. Structural concrete elements are generally made with concrete having a compressive strength of 20 to 35 MPa. Lately, there is an increase in use of high strength concrete (HSC) in major construction projects such as high-rise buildings, and bridges involving members of different sizes and shapes. The compressive strength of concrete is used as the most basic and important material property in the design of reinforced concrete structures. It has become a problem to use this value as the control specimen sizes and shapes are different from country to country. In India, the characteristic compressive strength is usually measured based on 150 mm cubes [1]. But, the ACI code of practice specifies the design compressive strength based on the standard 150x300 mm cylinders [2]. The use of 100x200 mm cylinders gained more acceptance as the need to test high strength concrete increases [3]. In this context the size and shape of concrete becomes an important parameter for the compressive strength. In view of the significance of compressive strength of concrete and due to the fact that the structural elements of different sizes and shapes are used, it is proposed to investigate the effect of size and shape of the specimen on the compressive strength of concrete. In this work, specimens of plain as well as Glass Fiber Reinforced Concrete (GFRC) specimens are cast in order to carry out a comparative study.


The High strength concrete defined as per IS 456 as the concrete having characteristic compressive strength more than 65 MPa. The concrete when subject to fire i.e. elevated temperatures loses its properties at a rapid rate. In the present investigation, ordinary vibrated concrete of M90 grade was developed as per the IS 10262. The hardened properties of concrete like compressive strength and split tensile strength were determined for concrete at ordinary temperature. The concrete specimens were subjected to elevated temperatures of 400oC, 600 oC, and 800 oC and then the specimens were brought to room temperature under different cooling regimes like air cooling and water quenching. The compressive residual strength of concrete was determined and a typical compared was made with the control specimen. The decrease in compressive strength of concrete at 800 oC was high compared to that at 400 oC.


2011 ◽  
Vol 261-263 ◽  
pp. 233-237 ◽  
Author(s):  
Zhao Hui Lu ◽  
Zhi Wu Yu ◽  
Yan Gang Zhao

The paper discusses the modulus of elasticity of plain concrete for a wide range of compressive strength. A large volume of selected experimental data has been collected from existing literature and then analyzed. Particular emphasis has been given to studying the effects of concrete compressive strength and the type of coarse aggregate on the modulus of elasticity of plain concrete. The adequacy and applicability of the existing models for predicting the modulus of elasticity of high-strength concrete has been critically examined, and a new empirical model is proposed to cover concrete strength up to 125 MPa. The new empirical model seems to perform much better when applied to the published experimental data on normal weight concrete over a wide strength range.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Neno Torić ◽  
Ivica Boko ◽  
Bernardin Peroš

This paper presents an experimental study of behaviour of high-strength concrete at high temperature. Reduction of the mechanical properties of concrete was determined starting from the period when the concrete specimens were heated to the maximum temperature and cooled down to ambient temperature and the additional 96 hours after the initial cooling of the specimens. The study includes determination of compressive strength, dynamic and secant modulus of elasticity, and stress-strain curves of concrete specimens when exposed to temperature level up to 600°C. The study results were compared with those obtained from other studies, EN 1994-1-2 and EN 1992-1-2. Tests point to the fact that compressive strength of concrete continues to reduce rapidly 96 hours after cooling of the specimens to ambient temperature; therefore indicating that the mechanical properties of concrete have substantial reduction after being exposed to high temperature. The study of the dynamic and secant modulus of elasticity shows that both of the properties are reduced but remain constant during the period of 96 hours after cooling. The level of postfire reduction of compressive strength of the analyzed concrete is substantial and could significantly affect the postfire load bearing capacity of a structure.