Detection Properties of CdZnTe Semiconductor for Diagnostic X-Ray Spectroscopic Applications

2005 ◽  
Vol 480-481 ◽  
pp. 53-58 ◽  
Author(s):  
M.B. Freitas ◽  
F.H.M. Medeiros ◽  
Elisabeth M. Yoshimura

Currently, many semiconductor compounds, particularly Cd1-xZnxTe, have attracted attention for applications in detection of radiation, due to the very good resolution without cryogenic cooling (a 1.3 keV-FWHM at the 122 keV line from 57Co is reported for some detectors). In this study the properties of a zinc doped cadmium telluride detector mounted on a thermoelectric cooler (Amptek Inc., model XR-100T-CZT) were studied. The detection system is based on a Cd0.9Zn0.1Te crystal of 3x3x2 mm, which operates at approximately -21°C and uses a rise time discrimination (RTD) circuit to improve the energy resolution. Although the quantum efficiency of this compound is very high, the small dimensions of the crystal limit its use to low energy photons (some hundreds of keV). Because of the carrier trapping characteristics of CZT, the experimental determination of the response function is essential. In this work it was measured in the range of energies from 10 to 400 keV, employing gamma rays and fluorescence x-rays from different sources (57Co, 133Ba, 152Eu and 241Am). In spite of the experimental difficulties, the x-ray escape fraction was also evaluated, making it possible the correction of the distortion it causes in the measured spectra. Measurements of x-ray spectra produced by a tungsten tube operating at small currents were carried out, and the stripping procedure was performed, taking into account the two contributions (efficiency and escape fraction). Results obtained point to the feasibility of use of this detector for in-situ diagnostic x-ray spectroscopy, provided that low intensity beams are available.

1980 ◽  
Vol 24 ◽  
pp. 123-138 ◽  
Author(s):  
Herbert E. Göbel

AbstractBy collecting the diffracted X-rays in a focussing powder diffractometer with a linear position-sensitive detector (PSD), the data accumulation time can be widely reduced. Due to the focussing properties of the geometrical arrangement good resolution can be simultaneously achieved over a few degrees of the diffraction angle 2 Theta. The full pattern is collected by scanning the PSD along the entire 2 Theta arc. Scanning speeds of several hundred degrees per minute are possible and still yield well plotted diagrams.This work demonstrates the performance of the system in different tasks of X-ray powder diffraction such as identification of unknown materials, quantitative analysis, determination of lattice constants and microcrystalline properties. The results, evaluated by parts of the program system DIFFRAC 11, show that the accuracy and resolution of the continuously scanning PSD technique match these tasks without difficulty and reach the precision limits of powder diffractometry itself. It is demonstrated that the data collection velocity, which matches well the data evaluation times, is not the only advantage compared to conventional diffractometets.


Author(s):  
J N Chapman ◽  
W A P Nicholson

Energy dispersive x-ray microanalysis (EDX) is widely used for the quantitative determination of local composition in thin film specimens. Extraction of quantitative data is usually accomplished by relating the ratio of the number of atoms of two species A and B in the volume excited by the electron beam (nA/nB) to the corresponding ratio of detected characteristic photons (NA/NB) through the use of a k-factor. This leads to an expression of the form nA/nB = kAB NA/NB where kAB is a measure of the relative efficiency with which x-rays are generated and detected from the two species.Errors in thin film x-ray quantification can arise from uncertainties in both NA/NB and kAB. In addition to the inevitable statistical errors, particularly severe problems arise in accurately determining the former if (i) mass loss occurs during spectrum acquisition so that the composition changes as irradiation proceeds, (ii) the characteristic peak from one of the minority components of interest is overlapped by the much larger peak from a majority component, (iii) the measured ratio varies significantly with specimen thickness as a result of electron channeling, or (iv) varying absorption corrections are required due to photons generated at different points having to traverse different path lengths through specimens of irregular and unknown topography on their way to the detector.


2020 ◽  
Author(s):  
Keishiro Yamashita ◽  
Kazuki Komatsu ◽  
Hiroyuki Kagi

An crystal-growth technique for single crystal x-ray structure analysis of high-pressure forms of hydrogen-bonded crystals is proposed. We used alcohol mixture (methanol: ethanol = 4:1 in volumetric ratio), which is a widely used pressure transmitting medium, inhibiting the nucleation and growth of unwanted crystals. In this paper, two kinds of single crystals which have not been obtained using a conventional experimental technique were obtained using this technique: ice VI at 1.99 GPa and MgCl<sub>2</sub>·7H<sub>2</sub>O at 2.50 GPa at room temperature. Here we first report the crystal structure of MgCl2·7H2O. This technique simultaneously meets the requirement of hydrostaticity for high-pressure experiments and has feasibility for further in-situ measurements.


2013 ◽  
Vol 712-715 ◽  
pp. 293-297
Author(s):  
Li Li

Pt/Bi3.15Nd0.85Ti3O12(BNT)/Pt ferroelectric capacitors were monitored using in situ X-ray irradiation with 10 keV at BL14B1 beamline (Shanghai Synchrotron Radiation Facility). BL14B1 combined with a ferroelectric analyzer enabled measurements in situ of electrical performance. The hysteresis curve (PE) of distortion depended on the polarization during irradiation, but the diffracted intensities of the (117) peak did not change in the beginning. ThePEcurve had a negligible change from 2.09×109Gy to 4.45×109Gy. Finally, bothPrandPr+very rapidly increased, but the intensities of (117) decreased. The hysteresis loops were remarkably deformed at the maximum total dose of 4.87×109Gy.


Crystals ◽  
2018 ◽  
Vol 8 (7) ◽  
pp. 273 ◽  
Author(s):  
José Brandão-Neto ◽  
Leonardo Bernasconi

Macromolecular crystallography at cryogenic temperatures has so far provided the majority of the experimental evidence that underpins the determination of the atomic structures of proteins and other biomolecular assemblies by means of single crystal X-ray diffraction experiments. One of the core limitations of the current methods is that crystal samples degrade as they are subject to X-rays, and two broad groups of effects are observed: global and specific damage. While the currently successful approach is to operate outside the range where global damage is observed, specific damage is not well understood and may lead to poor interpretation of the chemistry and biology of the system under study. In this work, we present a phenomenological model in which specific damage is understood as the result of a single process, the steady excitation of crystal electrons caused by X-ray absorption, which acts as a trigger for the bulk effects that manifest themselves in the form of global damage and obscure the interpretation of chemical information from XFEL and synchrotron structural research.


2007 ◽  
Vol 130 ◽  
pp. 7-14 ◽  
Author(s):  
Andrew N. Fitch

The highly-collimated, intense X-rays produced by a synchrotron radiation source can be harnessed to build high-resolution powder diffraction instruments with a wide variety of applications. The general advantages of using synchrotron radiation for powder diffraction are discussed and illustrated with reference to the structural characterisation of crystalline materials, atomic PDF analysis, in-situ and high-throughput studies where the structure is evolving between successive scans, and the measurement of residual strain in engineering components.


Author(s):  
Weinong W. Chen ◽  
Matthew C. Hudspeth ◽  
Ben Claus ◽  
Niranjan D. Parab ◽  
John T. Black ◽  
...  

Split Hopkinson or Kolsky bars are common high-rate characterization tools for dynamic mechanical behaviour of materials. Stress–strain responses averaged over specimen volume are obtained as a function of strain rate. Specimen deformation histories can be monitored by high-speed imaging on the surface. It has not been possible to track the damage initiation and evolution during the dynamic deformation inside specimens except for a few transparent materials. In this study, we integrated Hopkinson compression/tension bars with high-speed X-ray imaging capabilities. The damage history in a dynamically deforming specimen was monitored in situ using synchrotron radiation via X-ray phase contrast imaging. The effectiveness of the novel union between these two powerful techniques, which opens a new angle for data acquisition in dynamic experiments, is demonstrated by a series of dynamic experiments on a variety of material systems, including particle interaction in granular materials, glass impact cracking, single crystal silicon tensile failure and ligament–bone junction damage.


2019 ◽  
Author(s):  
Christopher Jones ◽  
Matthew Asay ◽  
Lee Joon Kim ◽  
Jack Kleinsasser ◽  
Ambarneil Saha ◽  
...  

Here we apply microcrystal electron diffraction (MicroED) to the structural determination of transition metal complexes. We find that the simultaneous use of 300 keV electrons, very low electron doses, and an ultra-sensitive camera allows for the collection of data without cryogenic cooling of the stage. This technique reveals the first crystal structures of the classic zirconocene hydride, colloquially known as “Schwartz’s reagent”, a novel Pd(II) complex not amenable to solution-state NMR or X-ray crystallography, and five other paramagnetic or diamagnetic transition metal complexes.


Sign in / Sign up

Export Citation Format

Share Document