Ultrasonic Bonding on Unstable Pin

2016 ◽  
Vol 2016 (1) ◽  
pp. 000398-000401
Author(s):  
Henri Seppänen

Abstract In power electronics modules, ultrasonic wire bonding is a common method to make electronic connections between the connector pins and the IGBTs. In these modules the connector pins are often residing on top of the plastic frame. Due to the pins being in positions which are hard to reach, clamping of these pins is either suboptimal or not used. This poor or absent clamping combined with the plastic frame's elasticity (softness) means that the pin has more freedom to move compared to the bonding on a metal substrate or IC. In our experiments we measured the pin and the plastic frame displacement with a laser Doppler vibrometer during the ultrasonic heavy wire (400 um in diameter Al wire) bonding process. We measured that the press fitted pin can move laterally along the ultrasonic excitation axis (2.0 ± 0.2) um whereas the frame under the pin moved (0.3 ± 0.1) um. This indicates that the pin slips over the frame while bonding. The slipping of the pin is also visible on the ultrasonic frequency waveforms of the transducer. While molded pins in general are thought to be more stable compared to the press fitted pins, similar behavior is seen in heavy wire bonding where high ultrasonic power is needed. We measured molded frame displacement (0.6 ± 0.2) um while bonding on the pin. In this paper we show how to use process traces and visual inspection to detect unstable pins and how to improve bondability on unstable pins by selecting process parameters that are optimized for the unstable pins rather than stable surfaces.

Author(s):  
T. Calvin Tszeng

Despite being a critical phenomenon of tremendous technological significance in ultrasonic flip-chip and wire bonding processes of today’s microelectronic devices, interfacial bond formation still calls for better understanding at a fundamental level. The goal of the research is to improve these processes through better understanding and modeling of bond formation. This paper presents a micromechanics model that addresses increasing contact area during ultrasonic cyclic loading cycle. The micromechanics model provides interfacial shear stress as boundary condition to FEM simulations of ultrasonic bonding processes. Comparison between preliminary results and experimental data is conducted.


2021 ◽  
Vol 16 (5) ◽  
pp. 1934578X2110206
Author(s):  
Yongshuai Jing ◽  
Ruijuan Zhang ◽  
Lan Li ◽  
Danshen Zhang ◽  
Yu Liu ◽  
...  

In this study, response surface methodology (RSM) was used to optimize the ultrasonic-assisted extraction parameters of Sojae Semen Praeparatum polysaccharides (SSPP-80), the optimum conditions were determined as follows: ultrasonic frequency of 100 W, ultrasonic power of 80 Hz, ultrasonic temperature of 52℃, ultrasonic time of 23 minutes, and liquid to raw material ratio of 40 mL/g. Based on these conditions, polysaccharides extraction rate was 7.72% ± 0.26%. Then, 2 novel polysaccharides (SSPP-80‐1, SSPP-80‐2) were isolated from SSPP by DEAE-cellulose 52 chromatography. The chemical compositions, physicochemical properties, and structure of SSPPs were investigated by simultaneous thermal analyzer (TGA), scanning electron microscopy (SEM), fourier transform infrared spectroscopy (FI-IR), and high-performance liquid chromatography (HPLC). The results showed that SSPP-80 and 2 fractions were mainly composed of mannose (Man), glucose (Glc), galactose (Gal), xylose (Xyl), and arabinose (Ara). In addition, the antioxidant activities were evaluated against the DPPH and hydroxyl radical in vitro, the IC50 of SSPP-80, SSPP-80‐1 and SSPP-80‐2 against DPPH free radical were 4.407, 8.267, and 5.204 mg/mL, respectively, whereas the IC50values for removing hydroxyl groups were 5.318, 3.516, and 4.016 mg/mL, respectively. It demonstrated that SSPP-80 and 2 fractions had certain antioxidant activity. Theoretical basis for use of Sojae Semen Praeparatum polysaccharides was provided by this study.


2011 ◽  
Vol 295-297 ◽  
pp. 1860-1865 ◽  
Author(s):  
Zhi Zhang ◽  
Chao Liu ◽  
Gong Duan Fan ◽  
Jing Luo ◽  
Yan Dong Wang

The control parameters of the removal of Chlorella pyrenoidosa, which was irradiated by low frequency ultrasonic, is optimized by using single factor experiments and response surface methodology (RSM). First of all, the approximate ranges of the ultrasonic frequency, the ultrasonic power and the irradiation time were estimated with single factor experiments for the further experiments. And then the optimized values of the three control parameters were determined, which were analyzed by using central composite design (CCD) and RSM. The results showed that the removal rate of chlorophyll-a could reach to 64.1% after the irradiation for 6.34min by using ultrasonic of 77.7 kHz and 250W. Ultrasonic technology can remove Chlorella pyrenoidosa cells in water quickly and effectively, so as to achieve the purpose of water purification.


Author(s):  
Jiromaru TSUJINO ◽  
Masataka KURODA ◽  
Mitsuo HORIKOSHI ◽  
Hidetoshi SUGIMOTO

2019 ◽  
Vol 2019 (1) ◽  
pp. 000509-000514
Author(s):  
Reinhard Schemmel ◽  
Florian Eacock ◽  
Collin Dymel ◽  
Tobias Hemsel ◽  
Matthias Hunstig ◽  
...  

Abstract Ultrasonic joining is a common industrial process. To build electrical connections in the electronics industry, uni-axial and torsional ultrasonic vibration have been used to join different types of workpieces for decades. Many influencing factors like ultrasonic power, bond normal force, bond duration and frequency are known to have a high impact on bond quality and reliability. Multi-dimensional bonding has been investigated in the past to increase ultrasonic power and consequently bond strength. This contribution is focused on the comparison of circular, multi-frequency planar and uniaxial vibration trajectories used for ultrasonic bonding of copper pins on copper substrate. Bond quality was analyzed by shear tests, scanning acoustic microscopy and interface cross-sections.