scholarly journals GRAPHICAL METHOD FOR DETERMINATION OF MQ-SERIES GAS SENSOR CIRCUIT PARAMETERS FOR A STAND-ALONE GAS ALARM SYSTEM

Author(s):  
Aye Taiwo AJIBOYE ◽  
Jaye Femi OPADIJI ◽  
Adebimpe Ruth AJAYI

Background: MQ-series gas sensors belong to the metal oxide semiconductor (MOS) family of sensors that can sense the presence of many gases. These sensors find their application in gas alarm systems as key components. While necessary sensor circuit output voltage value for alarm point in a stand-alone gas alarm system is desirable, but what exact combination of the sensor circuit parameters is required? Hitherto, the determination of these circuit parameters has not been given much attention in the research community. Aim: the purpose of this work is to explore a structured graphical approach of determination of MQ series gas sensor circuit parameters for a stand-alone gas alarm system that yields desired sensor circuit output voltage value for the alarm point; the main objective of the study was to develop mathematical model equations that relate the: (i) sensor resistance (RS) with the gas concentration (x) and the sensor resistance at standard calibration concentration of the sensor base gas in the clean air (Ro) and (ii) sensor circuit output voltage (VRL), load resistance (RL) and sensor resistance (RS). It is expected from the model equations developed that graphical correlations of the sensor circuits parameters will be generated. Using these graphs for a particular case of an MQ-4 gas sensor under the influence of LPG, the parameters that yield desired sensor circuit output voltage of 2V for 1000 ppm of LPG alarm point will be determined. Methods: Model equations were developed for the sensor dynamics, and based on these model equations, graphs for the determination of required sensor parameters were plotted for a case of MQ-4 gas sensor response to LPG. Results and Discussion: The results yielded optimal values for R_O,R_S and R_L of 20 kΩ, 30 kΩ and 20 kΩ respectively, for alarm settings of 1000 ppm and a desired sensor circuit output voltage of 2 V. Based on determined parameters, the calibration equation for determination of best concentration value for a given value of emulated LPG concentration was developed. Using the method proposed in this study makes the process of determining the MQ-series gas sensor circuit parameters less cumbersome as their value can easily be obtained from the resulting graphs. Conclusions: a structured graphical approach for determination of MQ-series gas sensor circuit parameters for alarm points in a stand-alone gas alarm system showed that using MQ-4 gas sensor and LPG as the target gas, and for a sensor circuit output voltage of 2 V for alarm point at 1000 ppm of LPG, the corresponding value of R_O, R_S and R_L obtained were 20 kΩ, 30 kΩ, and 20 kΩ respectively. Hence, a structured graphical approach is suitable for determining MQ series gas sensor circuit parameters for a stand-alone gas alarm system under the influence of its associated gases.

Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3861
Author(s):  
Jie Mei ◽  
Qiong Fan ◽  
Lijie Li ◽  
Dingfang Chen ◽  
Lin Xu ◽  
...  

With the rapid development of wearable electronics, novel power solutions are required to adapt to flexible surfaces for widespread applications, thus flexible energy harvesters have been extensively studied for their flexibility and stretchability. However, poor power output and insufficient sensitivity to environmental changes limit its widespread application in engineering practice. A doubly clamped flexible piezoelectric energy harvester (FPEH) with axial excitation is therefore proposed for higher power output in a low-frequency vibration environment. Combining the Euler–Bernoulli beam theory and the D’Alembert principle, the differential dynamic equation of the doubly clamped energy harvester is derived, in which the excitation mode of axial load with pre-deformation is considered. A numerical solution of voltage amplitude and average power is obtained using the Rayleigh–Ritz method. Output power of 22.5 μW at 27.1 Hz, with the optimal load resistance being 1 MΩ, is determined by the frequency sweeping analysis. In order to power electronic devices, the converted alternating electric energy should be rectified into direct current energy. By connecting to the MDA2500 standard rectified electric bridge, a rectified DC output voltage across the 1 MΩ load resistor is characterized to be 2.39 V. For further validation of the mechanical-electrical dynamical model of the doubly clamped flexible piezoelectric energy harvester, its output performances, including both its frequency response and resistance load matching performances, are experimentally characterized. From the experimental results, the maximum output power is 1.38 μW, with a load resistance of 5.7 MΩ at 27 Hz, and the rectified DC output voltage reaches 1.84 V, which shows coincidence with simulation results and is proved to be sufficient for powering LED electronics.


Atmosphere ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 647
Author(s):  
Tobias Baur ◽  
Johannes Amann ◽  
Caroline Schultealbert ◽  
Andreas Schütze

More and more metal oxide semiconductor (MOS) gas sensors with digital interfaces are entering the market for indoor air quality (IAQ) monitoring. These sensors are intended to measure volatile organic compounds (VOCs) in indoor air, an important air quality factor. However, their standard operating mode often does not make full use of their true capabilities. More sophisticated operation modes, extensive calibration and advanced data evaluation can significantly improve VOC measurements and, furthermore, achieve selective measurements of single gases or at least types of VOCs. This study provides an overview of the potential and limits of MOS gas sensors for IAQ monitoring using temperature cycled operation (TCO), calibration with randomized exposure and data-based models trained with advanced machine learning. After lab calibration, a commercial digital gas sensor with four different gas-sensitive layers was tested in the field over several weeks. In addition to monitoring normal ambient air, release tests were performed with compounds that were included in the lab calibration, but also with additional VOCs. The tests were accompanied by different analytical systems (GC-MS with Tenax sampling, mobile GC-PID and GC-RCP). The results show quantitative agreement between analytical systems and the MOS gas sensor system. The study shows that MOS sensors are highly suitable for determining the overall VOC concentrations with high temporal resolution and, with some restrictions, also for selective measurements of individual components.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 2103 ◽  
Author(s):  
Tae-Hee Han ◽  
So-Young Bak ◽  
Sangwoo Kim ◽  
Se Hyeong Lee ◽  
Ye-Ji Han ◽  
...  

This paper introduces a method for improving the sensitivity to NO2 gas of a p-type metal oxide semiconductor gas sensor. The gas sensor was fabricated using CuO nanowires (NWs) grown through thermal oxidation and decorated with ZnO nanoparticles (NPs) using a sol-gel method. The CuO gas sensor with a ZnO heterojunction exhibited better sensitivity to NO2 gas than the pristine CuO gas sensor. The heterojunction in CuO/ZnO gas sensors caused a decrease in the width of the hole accumulation layer (HAL) and an increase in the initial resistance. The possibility to influence the width of the HAL helped improve the NO2 sensing characteristics of the gas sensor. The growth morphology, atomic composition, and crystal structure of the gas sensors were analyzed using field-emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy, and X-ray diffraction, respectively.


1991 ◽  
Vol 63 (15) ◽  
pp. 1547-1552 ◽  
Author(s):  
Saad S. M. Hassan ◽  
Mona A. Ahmed ◽  
Sayed A. M. Marzouk ◽  
Eman M. Elnemma

2021 ◽  
Vol 9 (1) ◽  
pp. 46-49
Author(s):  
Fathoni ◽  
Agus Pracoyo ◽  
Totok Winarno ◽  
Rizal Sabillah

Changing the dc sgnal to ac signal is done for te purpose of load regulations, such as the ac motor speed, heater and lamp. Inverter work is done by ac rectification first and then converted again to a 1 phase ac signal. The ac output signal is a sinosoidal PWM (SPWM) type of unipolar 220 volts from the input 24 volt dc voltage. Unipolar SPWM signal generation is done by a microcontroller with programming. The number of counts (resolutions) of the SPWM signal and the period are set from the amount in the register, can be set to 8 bits or other constants. The power part of the SPWM inverter is the N channel MOSFET bridge circuit H with IR2110 solid state driver. Step transformer as a load while step-up the inverter output voltage. Determination of the output frequency is set through a rotary encoder that can be adjusted up (increment) or down (decrement). There are 5 frequency variations, namely 30, 40, 50, 60 and 70 Hz. To get the inverter efficiency, the type of MOSFET used is chosen to have the type that has a low RDS (on) value and the right driving pulse, according to the switch configuration. Measurement of the output frequency is done by reading the image on the osciloscope. The observations show a frequency value that is almost the same as the constant. The test results show the difference in output voltage which is reduced at a 30 watt load.


Sign in / Sign up

Export Citation Format

Share Document