scholarly journals A comparison of self-reported data on disability pension status with data from a nationwide administrative register

2010 ◽  
Vol 19 (2) ◽  
Author(s):  
Ingeborg Hartz ◽  
Aage Tverdal ◽  
Svetlana Skurtveit

<p><strong><em>Objectives: </em></strong>Validation studies of self-reported disability pension status have been scarce. The objective of this study was to estimate the sensitivity and specificity, as well as positive and negative predictive values of self-reported disability pension status using an official administrative register as reference standard.</p><p><strong><em>Methods: </em></strong>Data from Cohort of Norway (CONOR) surveys conducted in 2001 in the three Norwegian counties Oslo (HUBRO), Hedmark and Oppland (OPPHED) are included in this study, altogether 17,244 individuals. At the time of investigation, the subjects included in our study-population were aged 30-31, 40-41, 45-47 and 59-61 years. Self-reported data on disability pension status was compared with data from the nationwide population and housing census in Norway (Statistics Norway), performed November 3rd 2001. Data were linked using the unique 11-digit identification number, assigned to all individuals living in Norway.</p><p><strong><em>Results: </em></strong>Sensitivity and specificity for self-reported questions on disability pension were 97.6% (95% CI 91.1-94.1) and 96.8% (96.5-97.1). Positive and negative predictive values were 70.1% (67.9-72.3) and 99.8% (99.7-99.9). Validity measures in a subpopulation, those surveyed in October-November 2001, were almost identical as for the total study-population surveyed in 2001.</p><p><strong>Conclusion: </strong>The sensitivity of self-reported disability pension status was high. The positive predictive value was lower which may reflect a low prevalence.</p>

2017 ◽  
Vol 59 (2) ◽  
pp. 147-153 ◽  
Author(s):  
Jihee Kim ◽  
Eun-Kyung Kim ◽  
Min Jung Kim ◽  
Hee Jung Moon ◽  
Jung Hyun Yoon

Background The BI-RADS provides descriptors for microcalcifications based on morphology and distribution. However, the descriptor for category 4A microcalcifications is not specified in the 5th BI-RADS nor in the prior editions. Purpose To investigate how the category 4A assessment is applied to suspicious microcalcifications, and the appropriate descriptors for category 4A assessment for microcalcifications seen on mammography. Material and Methods From June 2008 to November 2011, 296 women with 305 suspicious microcalcifications that were assessed as BI-RADS category 4A, who underwent imaging-guided biopsy or surgery, were included. Mammograms were reviewed and imaging features were analyzed according to the morphology and distribution descriptors of the 5th edition of BI-RADS. Pathological results were considered as the reference standard. Positive predictive values were calculated and compared between morphology and distribution descriptors. Results The overall positive predictive value (PPV) of category 4A microcalcifications was 17.7% (54/305). Most common descriptors for category 4A microcalcifications were amorphous morphology (73.1%) and grouped distribution (71.1%). PPVs of individual morphology descriptors were as follows: amorphous = 7.2%; coarse heterogeneous = 12.8%; fine pleomorphic or fine linear/fine linear branching = 91.4% ( P < 0.001). PPVs of distribution descriptors were as follows: regional = 13.2%; grouped = 16.1%; linear/segmental = 54.5% ( P < 0.001). For morphology and distribution descriptors combinations, PPVs for amorphous/regional and amorphous/grouped microcalcifications were 6.8% and 6.9%, while PPVs of other combinations were higher than 10%, respectively. Conclusion Common descriptors used in category 4A assessment for microcalcifications are amorphous morphology and grouped distribution. PPV of amorphous/regional and amorphous/grouped microcalcifications were suitable for category 4A assessment.


Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 4689-4689
Author(s):  
Sriman Swarup ◽  
Somedeb Ball ◽  
Nimesh Adhikari ◽  
Anita Sultan ◽  
Khatrina Swarup ◽  
...  

Introduction: Heparin induced thrombocytopenia (HIT) is a severe prothrombotic condition, usually triggered by exposure to heparin products. It is characterized by platelet activation induced by the formation of antibodies to the platelet factor 4 (PF4)/ heparin polyanion complexes. Diagnostic algorithm includes clinical scoring (4T score) alongside serological test for detection of these antibodies (HIT-Ab), while serotonin release assay (SRA) remains the gold- standard for confirmation. The automated latex immunoturbidometric assay (LIA) has recently been FDA approved as a screening tool for HIT and is a potential alternative to the conventional particle immunofiltration assay (PIFA) for time-sensitive detection of HIT-Ab to guide treatment considerations. We recently introduced LIA in our institution. In this study, we present our experience with LIA in comparison to PIFA in the diagnosis of HIT. Methods: We retrospectively reviewed the charts of all the patients on whom a PIFA was ordered between March 2017 and March 2018 in our hospital. We collected information on the results of the PIFA and SRA (if available). We replaced PIFA with LIA for HIT screening. Then, we introduced a structured protocol for diagnosis of HIT in our institution by incorporating 4T scoring alongside LIA order in the electronic medical record (EMR), in December 2018. We reviewed the EMR of all the patients on whom HIT-Ab test (LIA) was ordered between January and June of 2019, and collected similar information as before. All the data were compiled in a single master excel sheet for calculation of performance characteristics (sensitivity, specificity, positive and negative predictive values) for both PIFA and LIA. A patient was considered to have the diagnosis of HIT if the result of SRA was available and positive. Results: In the first phase, a total of 31 orders for SRA was noted against 170 PIFA orders. Five patients had a positive SRA, of whom two were PIFA negative. Half the patients with a negative SRA result were positive for PIFA. Hence, the sensitivity and specificity of PIFA test for our study population were noted to be 60% and 50%, respectively. PIFA had a positive predictive value (PPV) of mere 18.75% for the diagnosis of HIT, whereas the negative predictive value (NPV) was found to be 86.66%. Introduction of structured protocol for HIT diagnosis substantially reduced the number of inappropriate SRA orders in the second phase. On review of data for six months with the new HIT-Ab test LIA, SRA was ordered in only eight patients, to go with 69 orders for the LIA. The result of LIA was positive in all three patients with a positive SRA, whereas it was false positive in four instances. Only one patient was negative for both LIA and SRA during this period. LIA was found to be 100% sensitive and 20% specific for the diagnosis of HIT in our sample. PPV and NPV for LIA were 42.85% and 100%, respectively. Conclusion: The sensitivity and specificity of LIA were found to be 100% and 20%, respectively, in our study population, which is different from the earlier report (Warkentin et al. 2017). The small sample size is a limitation of our study. Higher PPV and NPV for LIA, with its quick turnaround time, make it a useful alternative for the time-sensitive determination of post-test probability for HIT in patients. [HIT- Ab- Heparin Induced Thrombocytopenia Antibody, PIFA- Particle Immunofiltration Assay, LIA- Latex Immunoturbidometric Assay, SRA- Serotonin Release Assay, +ve- Positive, -ve - Negative, PPV- Positive Predictive Value, NPV- Negative Predictive Value] Disclosures No relevant conflicts of interest to declare.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Chengjun Li ◽  
Chang Liu ◽  
Bingqi Sun ◽  
Wei Zhang ◽  
Yang Wang ◽  
...  

Abstract Background Etiological diagnosis of tuberculous pleuritis is challenging, owing to a paucity of Mycobacterium tuberculosis (MTB) in the affected region. Moreover, currently available methods, such as the detection of acid-fast bacilli and microbiological culture, are not always conducive to timely diagnosis and treatment. In this study, we evaluated the performance of Xpert® MTB/RIF assay (hereinafter referred to as “Xpert”) in detecting MTB in difficult-to-diagnose patients using suspensions of pleural biopsy tissue specimens obtained under direct thoracoscopic guidance. Methods One hundred and sixty patients with an unexplained pleural effusion were included from the Shenyang Tenth People’s Hospital and Shenyang Chest Hospital, China, between 2017 and 2018. The included patients underwent thoracoscopy under local anesthesia, with an intercostal incision of approximately 1.0 cm for biopsy. The biopsy specimens were used for pathological and etiological examinations. The Xpert test was evaluated for its sensitivity and specificity, as well as positive and negative predictive values (PPV and NPV, respectively), against data obtained using standards: the BACTEC™ MGIT™ 960 liquid culture system and a composite reference standard (CRS). Results The sensitivity and specificity of Xpert were 68.8 and 64.6%, respectively, against the MGIT 960 culture data. The PPV and NPV of Xpert were 56.4 and 75.6%, respectively. The sensitivity of Xpert was 69.0% against the CRS data, which was significantly higher than that of MGIT 960 culture (56.6%). The PPV and NPV of Xpert against the CRS data were 100.0 and 57.3%, respectively. Conclusions Xpert is a good rule-in test but has limited value as a rule-out test for the diagnosis of tuberculosis pleuritis.


Antibodies ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 50
Author(s):  
Chin-Shern Lau ◽  
Tar-Choon Aw

While sensitivity and specificity are important characteristics for any diagnostic test, the influence of prevalence is equally, if not more, important when such tests are used in community screening. We review the concepts of positive/negative predictive values (PPV/NPV) and how disease prevalence affects false positive/negative rates. In low-prevalence situations, the PPV decreases drastically. We demonstrate how using two tests in an orthogonal fashion can be especially beneficial in low-prevalence settings and greatly improve the PPV of the diagnostic test results.


BMC Cancer ◽  
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Blanca Murillo-Ortiz ◽  
Abraham Hernández-Ramírez ◽  
Talia Rivera-Villanueva ◽  
David Suárez-García ◽  
Mario Murguía-Pérez ◽  
...  

Abstract Background Some evidence has shown that malignant breast tumours have lower electrical impedance than surrounding normal tissues. Electrical impedance could be used as an indicator for breast cancer detection. The purpose of our study was to analyse the sensitivity and specificity of electrical impedance mammography (EIM) and its implementation for the differential diagnosis of pathological lesions of the breast, either alone or in combination with mammography/ultrasound, in 1200 women between 25 and 70 years old. Methods This study is a prospective, cross-sectional epidemiological observational study of serial screening. The women were invited to participate and signed a consent letter. Impedance imaging of the mammary gland was evaluated with the computerized mammography equipment of MEIK electroimpedance v.5.6. (0.5 mA, 50 kHz), developed and manufactured by PKF SIM-Technika®. The successful identification of breast cancer along with the sensitivity, specificity, and positive and negative predictive values of EIM were determined as follows: % sensitivity; % specificity; % positive predictive value (PPV); and % negative predictive value (NPV). Results EIM had a sensitivity of 85% and a specificity of 96%; the positive predictive value was 12%, and the negative predictive value was 99%. Seven cases were biopsy confirmed cancers. Significant correlations between the electrical conductivity index and body mass index (BMI) (p = 0.04) and patient age were observed (p = 0.01). We also observed that the average conductivity distribution increased according to age group (p = 0.001). We used the chi-squared test to assess the interactions between percent density and BMI (normal < 25 kg/m2 (n = 310), overweight 25–29.9 kg/m2 (n = 418) and obese ≥30 (n = 437)) (p <  0.05). The patients with a diagnosis of mammary carcinoma had a BMI of 35.51 kg/m2. Conclusions Our results demonstrate that the use of monofrequency electrical impedance mammography (EIM) in the detection of breast cancer had a sensitivity and specificity of 85 and 96%, respectively. These findings may support future research in the early detection of breast cancer. EIM is a non-radiation method that may also be used as a screening method for young women with dense breasts and a high risk of developing breast cancer.


Author(s):  
Gerald J. Kost

ABSTRACT Context. Coronavirus infectious disease-19 (COVID-19) diagnostics require understanding of how predictive values depend on sensitivity, specificity, and especially, low prevalence. Clear expectations, high sensitivity and specificity, and manufacturer disclosure will facilitate excellence of tests. Objectives. To derive mathematical equations for designing and interpreting COVID-19 tests, assess Food and Drug Administration (FDA) Emergency Use Authorization and Health Canada minimum requirements, establish sensitivity and specificity tiers, and enhance clinical performance in low prevalence settings. Design. PubMed and other sources generated articles on COVID-19 testing and prevalence. EndNote X9.1 consolidated references. Mathematica and open access software helped prove equations, perform recursive calculations, graph multivariate relationships, and visualize patterns, including a new relationship, predictive value geometric mean-squared. Results. Derived equations were used to illustrate shortcomings of COVID-19 diagnostics in low prevalence. Visual logistics helped establish sensitivity/specificity tiers. FDA/Canada's 90% sensitivity, 95% specificity minimum requirements generate excessive false positives at low prevalence. False positives exceed true positives at &lt;5.3% prevalence, or if sensitivity is improved to 100% and specificity to 98%, at &lt;2% prevalence. Recursive testing improves predictive value. Three tiers emerged from these results. With 100% sensitivity, physicians can select desired predictive values, then input local prevalence, to determine suitable specificity. Conclusions. Understanding low prevalence impact will help healthcare providers meet COVID-19 needs for effective testing. Laypersons should receive clinical performance disclosure when submitting specimens. Home testing needs to meet the same high standards as other tests. In the long run, it will be more cost-effective to improve COVID-19 POC tests rather than repeat testing multiple times.


2020 ◽  
Author(s):  
Chengjun Li ◽  
Chang Liu ◽  
Bingqi Sun ◽  
Wei Zhang ◽  
Yang Wang ◽  
...  

Abstract Background: Etiological diagnosis of tuberculous pleuritis is challenging, owing to a paucity of Mycobacterium tuberculosis (MTB) in the affected region. Moreover, currently available methods, such as the detection of acid-fast bacilli and microbiological culture, are not always conducive to timely diagnosis and treatment. In this study, we evaluated the performance of Xpert® MTB/RIF assay (hereinafter referred to as “Xpert”) in detecting MTB in difficult-to-diagnose patients using suspensions of pleural biopsy tissue specimens obtained under direct thoracoscopic guidance.Methods: One hundred and sixty patients with an unexplained pleural effusion were included from the Shenyang Tenth People’s Hospital and Shenyang Chest Hospital, China, between 2017 and 2018. The included patients underwent thoracoscopy under local anesthesia, with an intercostal incision of approximately 1.0 cm for biopsy. The biopsy specimens were used for pathological and etiological examinations. The Xpert test was evaluated for its sensitivity and specificity, as well as positive and negative predictive values (PPV and NPV, respectively), against data obtained using standards: the BACTEC™ MGIT™ 960 liquid culture system and a composite reference standard (CRS).Results: The sensitivity and specificity of Xpert were 68.8% and 64.6%, respectively, against the MGIT 960 culture data. The PPV and NPV of Xpert were 56.4% and 75.6%, respectively. The sensitivity of Xpert was 69.0% against the CRS data, which was significantly higher than that of MGIT 960 culture (56.6%). The PPV and NPV of Xpert against the CRS data were 100.0% and 57.3%, respectively.Conclusions: Xpert is a good rule-in test but has limited value as a rule-out test for the diagnosis of tuberculosis pleuritis.


2011 ◽  
Vol 3 (2) ◽  
pp. 63-66
Author(s):  
Geeta Durdi ◽  
Kamal Patil ◽  
Lakshita Lumb

ABSTRACT Objectives To detect and compare the sensitivity and specificity of downstaging and visual inspection with acetic acid (VIA) and with Lugol's iodine (VILI). Methods Screening with downstaging, VIA and VILI were done on 680 women who fulfilled the inclusion criteria at a primary health center attached to the university hospital, over a period of one year. Those who had abnormal results in downstaging, VIA and VILI were biopsied and sensitivity, specificity, negative predictive value and positive predictive value were calculated. Results The sensitivities of downstaging, VIA and VILI were 54.55, 63.64 and 90.91% and specificities were 93.42, 95.07 and 97.46% respectively. The positive predictive value of downstaging, VIA and VILI were 12.01, 17.5 and 35.7% and negative predictive values were 99.2, 99.37 and 98.85% respectively. Conclusion VIA and VILI are suitable primary screening procedures as compared to downstaging because of high sensitivity and specificity. The negative predictive value of downstaging, VIA and VILI is better than the positive predictive value. Downstaging can be used in rural areas where acetic acid and Lugol's iodine are not available.


2002 ◽  
Vol 14 (3) ◽  
pp. 258-259 ◽  
Author(s):  
Karen W. Post ◽  
B. Helen Jost ◽  
J. Glenn Songer

A commercially available 1-hour enzyme immunoassay (EIA) for detecting the presence of Clostridium difficile toxins A and B was evaluated for use in diagnosis of C. difficile infections in neonatal swine. This test was compared with a tissue culture cytotoxicity assay, which is considered to be the reference standard for the detection of C. difficile toxins. Twenty-seven samples of colonic contents and 23 fecal samples were collected from freshly euthanized neonatal swine with a history of scours. Of the 50 specimens tested, 20 were positive by the EIA test and tissue culture and 24 were negative by both tests, for an overall correlation of 88%. The sensitivity and specificity of the EIA were 91% and 86%, respectively, and the positive and negative predictive values were 84% and 86%, respectively. The EIA test is considered suitable as an aid for the diagnosis of C. difficile enteritis because of the high correlation between EIA results and those of the tissue culture cytotoxicity assay.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Ahmad Mahran ◽  
Mohammed Khairy ◽  
Reham Elkhateeb ◽  
Abdel Rahman Hegazy ◽  
Ayman Abdelmeged ◽  
...  

Abstract Background The clinical implication of the increased serum progesterone level on the day of HCG administration in assisted reproduction treatment (ART) is still controversial. The current study aimed to compare the predictive value of serum progesterone on day of HCG administration / metaphase II oocyte (P/MII) ratio on IVF/ ICSI outcome to serum progesterone (P) level alone and the ratio of serum progesterone/estradiol level (P/E2) ratio in prediction of pregnancy rates after ART. Material & methods Two hundred patients admitted to the IVF/ICSI program at Minia IVF center in Egypt in the period from October 2016 to May 2018 were included in this study. Serum Progesterone (P) and Estradiol (E2) levels were estimated on the day of HCG administration. The ratio between serum P and the number of MII oocytes (P/MII ratio) was calculated and the predictive values of the three parameters (P, P/E2 ratio and P/MII ratio) in prediction of cycle outcomes were measured. Results P/ MII oocyte ratio was significantly lower in patients who attained clinical pregnancy (n = 97) as compared with those who couldn’t whilst there was no significant difference in P and P/E2 ratio between the two groups. Using a cut off value of 0.125, the sensitivity and specificity of progesterone/ MII ratio in prediction of no pregnancy in IVF/ICSI were 75.7 and 77.1% respectively with the area under The Receiver operating curve (ROC-AUC) = 0.808. The respective values of the ROC-AUC for the P and P/E2 ratio were 0.651 and 0.712 with sensitivity and specificity of 71.2 and 73.5%for P level and of 72.5 and 75.3% for P/E2 ratio. Implantation or clinical pregnancy rates were significantly different between patients with high and low P/MII ratio irrespective of day of embryo transfer (day 3 or 5). Conclusions In patients with normal ovarian response, serum progesterone on day of HCG / MII oocyte ratio can be a useful predictor of pregnancy outcomes and in deciding on freezing of all embryos for later transfer instead of high progesterone level alone.


Sign in / Sign up

Export Citation Format

Share Document