scholarly journals Performance studies on different okra varieties and hybrids under arid climatic conditions of Rajasthan

2021 ◽  
Vol 11 (01) ◽  
pp. 37-43
Author(s):  
MK Meena ◽  
SK Moond ◽  
Devkaran ◽  
M Meena ◽  
S Khardu
2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Abhishek Saxena ◽  
Varun Goel

A solar pond has been fabricated to analyze the thermal behavior of it, in the climatic conditions of Moradabad, Uttar Pradesh. Sodium chloride (NaCl) has been used to form a salt gradient for better performance, and a dark-colored (blackened) rigid surface bottom with 1 mm irregularities has been considered for trapping the heat in a good amount. A solar pond with a surface area of 2.56 m2and a depth of 1 m has been filled with salty water of various densities to form three salty water zones (upper convective, nonconvective, and heat storage). A few investigations have been carried out to evaluate the thermal efficiencies of three different zones of the solar pond. An attempt is also made to improve the thermal performance of the salt gradient solar pond.


Planta Medica ◽  
2016 ◽  
Vol 81 (S 01) ◽  
pp. S1-S381
Author(s):  
MD López ◽  
P Jara ◽  
S Fischer ◽  
R Wilckens ◽  
H Serri ◽  
...  

2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


2020 ◽  
pp. 7-10
Author(s):  
Vasiliy P. Petropavlovsky ◽  
◽  
Vyacheslav V. Marchenko ◽  
Lyudmila S. Vikulova ◽  
Olga D. Chepeleva ◽  
...  

Summary. Data on distribution of hypodermatosis among large horned cattle in Stavropol region are presented in the article. It was proved that this pathology is widespread in this region. From 12% to 38% of animals from the total number of examined livestock are affected. Ordinary subcutaneous botfly (stroma) Hypoderma bovis de Geer and south subcutaneous botfly (pischevodnik) Hypoderma lineatum de Villers parasites on large horned cattle. The species ratio of gadflies is: Hypoderma bovis (de Gee - 61.1%, Hypoderma lineatum de Villers - 38.9%). The disease is widespread in all climatic zones of Stavropol region. Animals of all age and sex groups are infected, but young animals are more often affected. Linear relationship between the indicators of the transformation of climatic conditions in Stavropol region, the spread of hypodermatosis and the timing of treatment and preventive measures were determined. Authors proved that the complete death of H. bovis and H. lineatum imago (regardless of the time of their hatching) was noted when the temperature drops to -3°C for two days. Thus, this temperature determines the start of treatment and preventive measures against hypodermatosis in the area of animal welfare. When analyzing the histomorphological changes caused by H. bovis and H. lineatum in the body of large horned cattle, perforation of the skin, swelling of adjacent tissues, disorganization of the stroma and structural elements, erythrocyte aggregation, hemorrhages, hydropic degeneration of cellular elements, tissue necrosis, polymorphonuclear leukocyte infiltration of affected organs and tissues were observed. The data on pathogenesis were presented, the analysis of economic damage and the veterinary and sanitary assessment of the products of slaughter of cattle with hypodermatosis were carried out.


2017 ◽  
Vol 6 (2) ◽  
pp. 92-97
Author(s):  
Craig Gingrich-Philbrook

In this brief essay, the author responds to a performative panel of essays by students of Devika Chawla. He situates his reading of the event betwixt and between typical modes of performance studies research, demonstrating how the panelists reveal narrative's power to reflect on the layering of time, power and privilege, and ways of knowing.


2016 ◽  
Vol 5 (1) ◽  
pp. 51-62
Author(s):  
Sharrell D. Luckett ◽  
Audrey Edwards ◽  
Megan J. Stewart

In 2013, Sharrell D. Luckett formed the Performance Studies & Arts Research Collective, which encourages members to explore their identities through the arts. Around this time, Audrey Edwards and Megan J. Stewart—both African American females and Collective members—became interested in autoethnography, and Luckett invited them to study closely with her. In this performative essay, Luckett, Edwards, and Stewart implicitly highlight various power negotiations enacted as professor/student, actress/stage manager, actress/assistant director, and mentor/mentee, while all working on their own autoethnographies, and while working collectively on Luckett's autoethnographic performance: YoungGiftedandFat.


2020 ◽  
Vol 14 (3) ◽  
pp. 7109-7124
Author(s):  
Nasreddine Sakhri ◽  
Younes Menni ◽  
Houari Ameur ◽  
Ali J. Chamkha ◽  
Noureddine Kaid ◽  
...  

The wind catcher or wind tower is a natural ventilation technique that has been employed in the Middle East region and still until nowadays. The present paper aims to study the effect of the one-sided position of a wind catcher device against the ventilated space or building geometry and its natural ventilation performance. Four models based on the traditional design of a one-sided wind catcher are studied and compared. The study is achieved under the climatic conditions of the South-west of Algeria (arid region). The obtained results showed that the front and Takhtabush’s models were able to create the maximum pressure difference (ΔP) between the windward and leeward of the tower-house system. Internal airflow velocities increased with the increase of wind speed in all studied models. For example, at Vwind = 2 m/s, the internal flow velocities were 1.7, 1.8, 1.3, and 2.5 m/s for model 1, 2, 3, and 4, respectively. However, at Vwind = 6 m/s, the internal flow velocities were 5.6, 5.5, 2.5, and 7 m/s for model 1, 2, 3, and 4, respectively. The higher internal airflow velocities are given by Takhtabush, traditional, front and middle tower models, respectively, with a reduction rate between the tower outlet and occupied space by 72, 42, 36, and 33% for the middle tower, Takhtabush, traditional tower, and the front model tower, respectively. This reduction is due to the due to internal flow resistance. The third part of the study investigates the effect of window (exist opening) position on the opposite wall. The upper, middle and lower window positions are studied and compared. The air stagnation or recirculation zone inside the ventilated space reduced from 55% with the lower window to 46% for the middle window and reached 35% for the upper window position. The Front and Takhtabush models for the one-sided wind catcher with an upper window position are highly recommended for the wind-driven natural ventilation in residential houses that are located in arid regions.


Sign in / Sign up

Export Citation Format

Share Document