Features of creating a test facility for small-sized aviation engines and power plants based on a climatic test unit

2019 ◽  
pp. 35-40
Author(s):  
M.M. Zhigunov ◽  
K.E. Mitrofanov
Author(s):  
Andrey S. KIRILLOV ◽  
Aleksandr P. PYSHKO ◽  
Andrey A. ROMANENKO ◽  
Valery I. YARYGIN

The paper describes an overview of the history of development and the current state of JSC “SSC RF-IPPE” reactor research and test facility designed for assembly, research and full-scale life energy tests of space nuclear power plants with a thermionic reactor. The leading specialists involved in development and operation of this facility are represented. The most significant technological interfaces and upgrade operations carried out in the recent years are discussed. The authors consider the use of an oil-free pumping system as part of this facility during degassing and life testing. Proposed are up-to-date engineering solutions for development of the automated special measurement system designed to record NPP performance, including volt-ampere characteristics together with thermophysical and nuclear physical parameters of a ground prototype of the space nuclear power plant. Key words: reactor research and test facility, thermionic reactor, life energy tests, oil-free pumping system, automated special measurement system, volt-ampere characteristics.


2008 ◽  
Vol 2008 ◽  
pp. 1-7 ◽  
Author(s):  
Mantas Povilaitis ◽  
Egidijus Urbonavičius

An issue of the stratified atmospheres in the containments of nuclear power plants is still unresolved; different experiments are performed in the test facilities like TOSQAN and MISTRA. MASPn experiments belong to the spray benchmark, initiated in the containment atmosphere mixing work package of the SARNET network. The benchmark consisted of MASP0, MASP1 and MASP2 experiments. Only the measured depressurisation rates during MASPn were available for the comparison with calculations. When the analysis was performed, the boundary conditions were not clearly defined therefore most of the attention was concentrated on MASP0 simulation in order to develop the nodalisation scheme and define the initial and boundary conditions. After achieving acceptable agreement with measured depressurisation rate, simulations of MASP1 and MASP2 experiments were performed to check the influence of sprays. The paper presents developed nodalisation scheme of MISTRA for the COCOSYS code and the results of analyses. In the performed analyses, several parameters were considered: initial conditions, loss coefficient of the junctions, initial gradients of temperature and steam volume fraction, and characteristic length of structures. Parametric analysis shows that in the simulation the heat losses through the external walls behind the lower condenser installed in the MISTRA facility determine the long-term depressurisation rate.


Author(s):  
Hans-Jürgen Rehder ◽  
Andreas Pahs ◽  
Martin Bittner ◽  
Frank Kocian

Axial turbines for aircraft engines and power plants have reached a very high level of development. Further improvements, in particular in terms of higher efficiency and reduced number of blades and stages, resulting in higher loads, are possible, but can only be achieved through a better understanding of the flow parameters and a closer connection between experiment and numerical design and simulation. An analysis of future demands from the industry and existing turbine research rigs shows that there appears a need for a powerful turbine test rig for aerodynamic experiments. This paper deals with the development and built up of a new so called Next Generation Turbine Test Facility (NG-Turb) at the German Aerospace Center (DLR) in Göttingen. The NG-Turb is a closed-circuit, continuously running facility for aerodynamic turbine investigations, allowing independent variation of engine relevant Mach and Reynolds numbers. The flow medium (dry air) is driven by a 4-stage radial gear compressor with a high pressure ratio and a wide inlet volume flow range. In a first stage the NG-Turb test section will allow investigations on single shaft turbines up to 2½ stages. In a further expansion stage the NG-Turb will be equipped with a second independent shaft system, then enabling experiments with configurations of high and low (or intermediate) pressure turbines and in particular offering the possibility for investigations at counter rotating turbines. Secondary air for cooling investigations can be provided by auxiliary screw compressors. Mass flow through the Turbine is determined redundantly with an uncertainty of about ±0.3%, using well calibrated Venturi nozzles upstream and downstream of the test section. The operation concept and main design features of the NG-Turb will be described and an overview of the applied standard measurement and data acquisition technics capturing efficiency, traverse data etc. will be given. Thermodynamic cycle calculations have been performed in order to simulate the flow circuit of the NG-Turb and to access whether turbine operating points can be driven within the performance map of the compressor system. Finally the calibration procedure for the Venturi nozzles, which has been conducted during the commissioning phase of the NG-Turb by applying a special calibration test section, is explained and some results will be shown.


2018 ◽  
Vol 4 (3) ◽  
pp. 179-183
Author(s):  
Andrey Kirillov ◽  
Valeriy Yarygin

Studies and tests are conducted to determine the performance of thermionic nuclear power plants (TNPP) a stage in which is pre-irradiation testing of laboratory thermionic converters (TIC) with flat and cylindrically shaped electrodes using test facilities fitted with automated data measurement systems (DMS). The TIC volt-ampere characteristics (VAC) are measured in the DMS jointly with the measured test section and experimental test facility temperature fields. The structure and the characteristics of a DMS based on products from ICP DAS Co., Ltd are presented. A developed VAC measurement program providing the operator with a convenient graphic interface and enabling adjustment of the measurement parameters has been considered. The VAC recording errors in the process of measurements have been determined using TIC simulators. The error in the VAC diffusion portion on a simulator (with a current of less than 3 A) is not more than 1%. Thanks to the use of modern components, the developed DMS offers extended functional capabilities for measuring the thermocouple signals in an experimental electrophysical test facility. The DMS structure provides for the convenience of scaling (through a larger number of measuring channels) and makes it possible to add modules from other manufacturers. The experience of operating this DMS will be used to develop the DMS for an in-pile test system designed for similar functions.


2002 ◽  
Vol 124 (2) ◽  
pp. 126-133 ◽  
Author(s):  
Eduardo Zarza ◽  
Loreto Valenzuela ◽  
Javier Leo´n ◽  
H.-Dieter Weyers ◽  
Martin Eickhoff ◽  
...  

The DISS (DIrect Solar Steam) project is a complete R+TD program aimed at developing a new generation of solar thermal power plants with direct steam generation (DSG) in the absorber tubes of parabolic trough collectors. During the first phase of the project (1996-1998), a life-size test facility was implemented at the Plataforma Solar de Almerı´a (PSA) to investigate the basic DSG processes under real solar conditions and evaluate the unanswered technical questions concerning this new technology. This paper updates DISS project status and explains O&M-related experience (e.g., main problems faced and solutions applied) with the PSA DISS test facility since January 1999.


Author(s):  
M. Eck ◽  
W.-D. Steinmann

The direct steam generation (DSG) is an attractive option regarding the economic improvement of parabolic trough technology for solar thermal electricity generation in the multi megawatt range. According to [1] and [2] a 10% reduction of the LEC is expected compared to conventional SEGS like parabolic trough power plants. The European DISS project has proven the feasibility of the DSG process under real solar conditions at pressures up to 100 bar and temperatures up to 400°C in more than 4000 operation hours [3]. In a next step the detailed engineering for a pre-commercial DSG solar thermal power plant will be performed. This detailed engineering of the collector field requires the consideration of the occurring thermohydraulic phenomena and their influence on the stability of the absorber tubes. A design tool has been developed at DLR calculating all relevant process parameters including pressure drop, temperature field and stress in the absorber tubes. The models implemented in this design tool have been validated in detail at the DISS test facility under real DSG conditions for pressures between 30 and 100 bar and inner diameters between 50 and 85 mm. The models have been implemented into a MATLAB® program to allow for a first quick determination of critical process conditions. Once critical process conditions have been identified the FEM package ANSYS® is used for a detailed investigation. This article summarises the models used and shows the design procedure for a DSG collector field. The design program has proven to be a reliable tool for the detailed design of DSG collector fields.


2010 ◽  
Vol 74 ◽  
pp. 266-271
Author(s):  
Konstantin Geimer ◽  
Markus Sauerborn ◽  
Bernhard Hoffschmidt ◽  
Mark Schmitz ◽  
Joachim Göttsche

The Solar-Institute Jülich (SIJ) has initiated the construction of the first and only German solar tower power plant and is now involved in the accompanying research. The power plant for experimental and demonstration purposes in the town of Jülich started supplying electric energy in the beginning of 2008. The central receiver plant features as central innovation an open volumetric receiver, consisting of porous ceramic elements that simultaneously absorb the concentrated sunlight and transfer the heat to ambient air passing through the pores so that an average temperature of 680°C is reached. The subsequent steam cycle generates up to 1.5 MWe. A main field of research at the SIJ is the optimization of the absorber structures. To analyze the capability of new absorber specimens a special test facility was developed and set up in the laboratory. A high-performance near-infrared radiator offers for single test samples a variable and repeatable beam with a power of up to 320 kW/m² peak. The temperatures achieved on the absorber surface can reach more than 1000°C. To suck ambient air through the open absorber - like on the tower - it is mounted on a special blower system. An overview about the test facility and some recent results will be presented.


1994 ◽  
Vol 116 (3) ◽  
pp. 137-141 ◽  
Author(s):  
D. C. Smith ◽  
E. E. Rush ◽  
C. W. Matthews ◽  
J. M. Chavez ◽  
P. A. Bator

The molten salt pump and valve (P&V) test loops at Sandia National Laboratories (SNL) National Solar Thermal Test Facility (NSTTF) operated between Jan. 1988 and Oct. 1990. The purpose of the P&V test was to demonstrate the performance, reliability, and service life of full-scale hot and cold salt pumps and valves for use in commercial central receiver solar power plants. The P&V test hardware consists of two pumped loops; the “Hot Loop” to simulate the hot (565°C) side of the receiver and the “Cold Loop” to simulate the receiver’s cold (285°C) side. Each loop contains a pump and five valves sized to be representative of a conceptual 60-MWe commercial solar power plant design. The hot loop accumulated over 6700 hours of operation and the cold loop over 2500 hours of operation. This project has demonstrated that standard commercial scale pump and valve designs will work in molten salt. The test also exposed some pitfalls that must be avoided in specifying such equipment. Although certainly not all of the pitfalls were discovered, careful design and specification should result in reliable or at least workable equipment.


Author(s):  
Wolfgang Flaig ◽  
Rainer Mertz ◽  
Joerg Starflinger

Supercritical fluids show great potential as future coolants for nuclear reactors, thermal power, and solar power plants. Compared to the subcritical condition, supercritical fluids show advantages in heat transfer due to thermodynamic properties near the critical point. A specific field of interest is an innovative decay heat removal system for nuclear power plants, which is based on a turbine-compressor system with supercritical CO2 as the working fluid. In case of a severe accident, this system converts the decay heat into excess electricity and low-temperature waste heat, which can be emitted to the ambient air. To guarantee the retrofitting of this decay heat removal system into existing nuclear power plants, the heat exchanger (HE) needs to be as compact and efficient as possible. Therefore, a diffusion-bonded plate heat exchanger (DBHE) with mini channels was developed and manufactured. This DBHE was tested to gain data of the transferable heat power and the pressure loss. A multipurpose facility has been built at Institut für Kernenergetik und Energiesysteme (IKE) for various experimental investigations on supercritical CO2, which is in operation now. It consists of a closed loop where the CO2 is compressed to supercritical state and delivered to a test section in which the experiments are run. The test facility is designed to carry out experimental investigations with CO2 mass flows up to 0.111 kg/s, pressures up to 12 MPa, and temperatures up to 150 °C. This paper describes the development and setup of the facility as well as the first experimental investigation.


Author(s):  
Suleiman Al Issa ◽  
Patricia B. Weisensee

A multiphase flow test facility was built at the Department of Nuclear Engineering at the Technical University Munich. The main goal of this facility is to investigate the condensation of steam bubbles injected into a vertical large diameter pipe (104 mm) with flowing subcooled water (6–15 K) at low pressure conditions (1.1–1.45 bar). Current experimental investigations will contribute to a better understanding of subcooled boiling at low pressures, accidental conditions in nuclear power plants and low-pressure research reactors and correlations for the validation of CFD codes. The test section is a 1 m long transparent pipe that is surrounded by an 18×18 cm rectangular “aquarium” filled with distilled water for refraction correction. High-speed camera (HSC) recording was used to gather data about condensing bubbles including bubble diameter, shape and rising velocity. Steam was injected via two different vertical injection nozzles with an inner diameter of 4 and 6 mm, respectively, directly into the center of the test section. The present experiments were carried out at three different steam superficial velocities, water superficial velocities and water temperatures leading to bubble diameters up to 50 mm and bubble relative velocities around 1 m/s. The measurements enabled the calculation of bubble Reynolds and Nusselt numbers and comparison with correlations given in literature. Even though significant differences could be observed between the two injection nozzles with respect to the bubble’s diameter and velocity, the Nusselt and Reynolds numbers are in the same range of values. The bigger bubbles of the 6 mm with respect to the 4 mm nozzle are almost neutralized by the lower rising velocities.


Sign in / Sign up

Export Citation Format

Share Document