scholarly journals Evaluation of Usability of the Tiger Full Foot 3D Scanner for the Measurements of Basic Foot Dimensions in Clinical Practice

Author(s):  
Ondřej Laštovička ◽  
Roman Cuberek ◽  
Miroslav Janura ◽  
Tomáš Klein

Background: Foot dimension information is important both for footwear design and clinical applications. In recent years, non-contact three-dimensional foot digitizers/scanners became popular as they are non-invasive and are both valid and reliable for the most of measures. Some of them also offer automated calculations of basic foot dimensions. The study aimed to determine test-retest reliability, objectivity, and concurrent validity of the Tiger full foot 3D scanner as well as the relationship between the manual measures of the medial longitudinal arch of the foot and its alternative parameters obtained automatically by the scanner. Methods: Intraclass correlation coefficients and the values of minimal detectable change were used to assess the reliability and objectivity of the scanner. Concurrent validity and the relationship between the arch height measures were determined by the Pearson's correlation coefficient and the limits of agreement between the scanner and the calliper method. Results: Both the relative and absolute agreement between the repeated measurements obtained by the scanner show excellent reliability and objectivity of linear measures and only good to nearly good test-retest reliability and objectivity of the arch height. Correlations between the values obtained by the scanner and the calliper were generally higher in linear measures (rp{greater than or equal to}0.929). The representativeness of state of bony architecture by the soft tissue margin of the medial foot arch demonstrate the lowest correlations among the all measurements (rp{less than or equal to}0.526). Conclusions: The Tiger full foot 3D scanner offers both excellent reliability and objectivity in linear measures, which correspond to those obtained by the calliper method. However, values obtained by the both methods shouldn't be used interchangeably. The arch height measure is less accurate, which could limit its use in some clinical applications. Orthotists and related professions probably appreciate scanner more than other specialists.

2021 ◽  
Author(s):  
A Wallin ◽  
M Kierkegaard ◽  
E Franzén ◽  
S Johansson

Abstract Objective The mini-BESTest is a balance measure for assessment of the underlying physiological systems for balance control in adults. Evaluations of test–retest reliability of the mini-BESTest in larger samples of people with multiple sclerosis (MS) are lacking. The purpose of this study was to investigate test–retest reliability of the mini-BESTest total and section sum scores and individual items in people with mild to moderate overall MS disability. Methods This study used a test–retest design in a movement laboratory setting. Fifty-four people with mild to moderate overall MS disability according to the Expanded Disability Status scale (EDSS) were included, with 28 in the mild subgroup (EDSS 2.0–3.5) and 26 in the moderate subgroup (EDSS 4.0–5.5). Test–retest reliability of the mini-BESTest was evaluated by repeated measurements taken 1 week apart. Reliability and measurement error were analyzed. Results Test–retest reliability for the total scores were considered good to excellent, with intraclass correlation coefficients of .88 for the whole sample, .83 for the mild MS subgroup, and .80 for the moderate MS subgroup. Measurement errors were small, with standard error of measurement and minimal detectable change of 1.3 and 3.5, respectively, in mild MS, and 1.7 and 4.7, respectively, in moderate MS. The limits of agreement were − 3.4 and 4.6. Test–retest reliability for the section scores were fair to good or excellent; weighted kappa values ranged from .62 to .83. All items but 1 showed fair to good or excellent test–retest reliability, and percentage agreement ranged from 61% to 100%. Conclusions The mini-BESTest demonstrated good to excellent test–retest reliability and small measurement errors and is recommended for use in people with mild to moderate MS. Impact Knowledge of limits of agreement and minimal detectable change contribute to interpretability of the mini-BESTest total score. The findings of this study enhance the clinical usefulness of the test for evaluation of balance control and for designing individually customized balance training with high precision and accuracy in people with MS.


2015 ◽  
Vol 10 (4) ◽  
pp. 509-515 ◽  
Author(s):  
Wissem Dhahbi ◽  
Anis Chaouachi ◽  
Johnny Padulo ◽  
David G. Behm ◽  
Karim Chamari

Purpose:To examine the concurrent validity and absolute and relative reliabilities of a commando-specific power test.Participants:21 antiterrorism commandos.Methods:All participants were assessed on a 5-m rope-climbing test (RCT) and the following tests: pull-ups, push-ups, estimated-1-repetition-maximum (est-1RM), medicine-ball put, and handgrip-strength test. The stopwatch method related to the execution time (ET) was validated by comparison with video motion analysis. The best individual attempt of 3 trials was kept for analysis, and the performance was expressed in absolute power output (APO) and body-mass relative power output (RPO).Results:Stopwatch assessment had an excellent criterion validity (r = .99, P < .001), intraclass correlation coefficient (ICC3,1) of .98, standard errors of measurement (SEM%) of 1.19%, bias ± the 95% limits of agreement of 0.03 ± 0.26 s, and minimal detectable change (MDC95) of 0.51 s. The ET, APO, and RPO were significantly correlated (P < .05) with all cited tests (absolute-value r range .55−.98), while est-1RM was not significantly correlated with the other tests. Test-retest reliability coefficients were excellent for ET, APO, and RPO (ICC3,1 > .90). The SEM% values for the ET, APO, and RPO were all under 5% (range 3.73−4.52%), all being smaller than the corresponding smallest worthwhile change. The coefficients of variation for the ET, APO, and RPO were all under 10%. %MDC95 ranged from 10.37% to 12.53%.Conclusions:Considering the strong concurrent validity and excellent test–retest reliability, the RCT is simple to administer, has ecological validity, and is a valid specific field test of upper-body power for commandos and, in addition, can be accurately assessed with a stopwatch.


Author(s):  
Daniela Claessens ◽  
Alexander K. Schuster ◽  
Ronald V. Krüger ◽  
Marian Liegl ◽  
Laila Singh ◽  
...  

AbstractIn this study, the test-retest-reliability as one aspect of reliability of metamorphopsia measurements using a computer-based measuring method was determined in patients with macular diseases. Metamorphopsia amplitude, position, and area were quantified using AMD – A Metamorphopsia Detector software (app4eyes GmbH & Co. KG, Germany) in patients with diabetic, myopic, or uveitic macular edema, intermediate or neovascular age-associated macular degeneration, epiretinal membrane, vitelliform maculopathy, Irvine-Gass syndrome, or macular edema due to venous retinal occlusion. The intraclass correlation coefficient (ICC) was calculated in order to determine the repeatability of two repeated measurements and was used as an indicator of the reliability of the measurements. In this study, metamorphopsia measurements were conducted on 36 eyes with macular diseases. Metamorphopsia measurements made using AMD – A Metamorphopsia Detector software were highly reliable and repeatable in patients with maculopathies. The intraclass correlation coefficient of all indices was excellent (0.95 – 0.97). For diseases of the vitreoretinal interface or macular diseases with intra- or subretinal edema, this metamorphopsia measurement represents a supplement for visual function testing in the clinic, as well as in clinical studies.


2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Juan Pablo Martinez-Cano ◽  
Daniel Vernaza-Obando ◽  
Julián Chica ◽  
Andrés Mauricio Castro

Abstract Objective The aim of this study was to translate to Spanish the patellofemoral pain and osteoarthritis subscale of the knee injury and osteoarthritis outcome score (KOOS-PF) and validate this Spanish version of a disease-specific patient-reported outcome measure (PROM) for patellofemoral pain. Results The KOOS-PF was translated to Spanish and sixty patients with patellofemoral pain and/or osteoarthritis accepted to complete the questionnaire. 1-week later 58 patients answered the questions again for the test–retest reliability validation and finally 55 patients completed 1-month later for the responsiveness assessment. The Spanish version showed very good internal consistency (Cronbach’s alpha: 0.93) and test–retest reliability (intraclass correlation coefficient: 0.82). Responsiveness was confirmed, showing a strong correlation with the global rating of change (GROC) score (r 0.64). The minimal detectable change was 11.1 points, the minimal important change was 17.2 points, and there were no floor or ceiling effects for the score.


Author(s):  
Katherine L. Marks ◽  
Alessandra Verdi ◽  
Laura E. Toles ◽  
Kaila L. Stipancic ◽  
Andrew J. Ortiz ◽  
...  

Objective The purpose of this study was to examine the psychometric properties of an ecological vocal effort scale linked to a voicing task. Method Thirty-eight patients with nodules, 18 patients with muscle tension dysphonia, and 45 vocally healthy control individuals participated in a week of ambulatory voice monitoring. A global vocal status question was asked hourly throughout the day. Participants produced a vowel–consonant–vowel syllable string and rated the vocal effort needed to produce the task on a visual analog scale. Test–retest reliability was calculated for a subset using the intraclass correlation coefficient, ICC(A, 1). Construct validity was assessed by (a) comparing the weeklong vocal effort ratings between the patient and control groups and (b) comparing weeklong vocal effort ratings before and after voice rehabilitation in a subset of 25 patients. Cohen's d, the standard error of measurement ( SEM ), and the minimal detectable change (MDC) assessed sensitivity. The minimal clinically important difference (MCID) assessed responsiveness. Results Test–retest reliability was excellent, ICC(A, 1) = .96. Weeklong mean effort was statistically higher in the patients than in controls ( d = 1.62) and lower after voice rehabilitation ( d = 1.75), supporting construct validity and sensitivity. SEM was 4.14, MDC was 11.47, and MCID was 9.74. Since the MCID was within the error of the measure, we must rely upon the MDC to detect real changes in ecological vocal effort. Conclusion The ecological vocal effort scale offers a reliable, valid, and sensitive method of monitoring vocal effort changes during the daily life of individuals with and without vocal hyperfunction.


2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Xia ◽  
William Ho Cheung Li ◽  
Tingna Liang ◽  
Yuanhui Luo ◽  
Laurie Long Kwan Ho ◽  
...  

Objectives: This study conducted a linguistic and psychometric evaluation of the Chinese Counseling Competencies Scale-Revised (CCS-R).Methods: The Chinese CCS-R was created from the original English version using a standard forward-backward translation process. The psychometric properties of the Chinese CCS-R were examined in a cohort of 208 counselors-in-training by two independent raters. Fifty-three counselors-in-training were asked to undergo another counseling performance evaluation for the test-retest. The confirmatory factor analysis (CFA) was conducted for the Chinese CCS-R, followed by internal consistency, test-retest reliability, inter-rater reliability, convergent validity, and concurrent validity.Results: The results of the CFA supported the factorial validity of the Chinese CCS-R, with adequate construct replicability. The scale had a McDonald's omega of 0.876, and intraclass correlation coefficients of 0.63 and 0.90 for test-retest reliability and inter-rater reliability, respectively. Significantly positive correlations were observed between the Chinese CCS-R score and scores of performance checklist (Pearson's γ = 0.781), indicating a large convergent validity, and knowledge on drug abuse (Pearson's γ = 0.833), indicating a moderate concurrent validity.Conclusion: The results support that the Chinese CCS-R is a valid and reliable measure of the counseling competencies.Practice implication: The CCS-R provides trainers with a reliable tool to evaluate counseling students' competencies and to facilitate discussions with trainees about their areas for growth.


2019 ◽  
Vol 48 (Supplement_4) ◽  
pp. iv18-iv27 ◽  
Author(s):  
Kitima Rongsawad ◽  
Laddawon Worawan ◽  
Karnsiree Jirarojprapa ◽  
Sararat Kaewkham ◽  
Sarawut Khattiwong

Abstract Introduction Static postural stability is the ability to maintain the posture with minimum sway. Increasing postural sway during standing in different sensory conditions is associated with aging due to decline in sensory and motor functions. Sway area measured by using sway meter is usually simple method for assessing postural stability in elderly subjects. Like many biological measurements, sway area has an intrinsic variability that affects their test-retest reliability and responsiveness of postural stability assessment. The minimal detectable change (MDC) is ability to detect smallest change beyond measurement error that reflects a reliable change. Therefore, the MDC value could provide information of clinical relevance on postural stability. The aims of this study were to determine test-retest reliability and MDC of sway area obtained from sway meter in elderly subjects. Methods Twelve healthy elderly subjects aged 60 years and above were participated in this study. The test and retest repeatability of postural sway measurements were performed twice with a 1-hour interval. For each subject was assess postural sway using Lord’s sway meter during standing on 4 sensory conditions for 30 seconds of each condition. The test-retest reliability of sway area was calculated using intraclass correlation coefficient. The MDC for each sway area was calculated to quantify clinical relevance. Results The test-retest reliability of sway area revealed good to excellent reliability ranged from 0.85 to 0.94. Standard error of measurement (SEM) and MDC ranged from 75 to 205 mm2 and 209 to 568 mm2, respectively. Discussion and Conclusion Our findings reveal that sway area in different sensory conditions could be used in assessment of postural stability in elderly subjects. SEM and MDC of sway area increased when subjects were asked to close their eyes and on foam surface. The sway meter is a reliable tool for assessing postural stability in clinical setting.


Sensors ◽  
2019 ◽  
Vol 20 (1) ◽  
pp. 37 ◽  
Author(s):  
Christopher Buckley ◽  
M. Encarna Micó-Amigo ◽  
Michael Dunne-Willows ◽  
Alan Godfrey ◽  
Aodhán Hickey ◽  
...  

Asymmetry is a cardinal symptom of gait post-stroke that is targeted during rehabilitation. Technological developments have allowed accelerometers to be a feasible tool to provide digital gait variables. Many acceleration-derived variables are proposed to measure gait asymmetry. Despite a need for accurate calculation, no consensus exists for what is the most valid and reliable variable. Using an instrumented walkway (GaitRite) as the reference standard, this study compared the validity and reliability of multiple acceleration-derived asymmetry variables. Twenty-five post-stroke participants performed repeated walks over GaitRite whilst wearing a tri-axial accelerometer (Axivity AX3) on their lower back, on two occasions, one week apart. Harmonic ratio, autocorrelation, gait symmetry index, phase plots, acceleration, and jerk root mean square were calculated from the acceleration signals. Test–retest reliability was calculated, and concurrent validity was estimated by comparison with GaitRite. The strongest concurrent validity was obtained from step regularity from the vertical signal, which also recorded excellent test–retest reliability (Spearman’s rank correlation coefficients (rho) = 0.87 and Intraclass correlation coefficient (ICC21) = 0.98, respectively). Future research should test the responsiveness of this and other step asymmetry variables to quantify change during recovery and the effect of rehabilitative interventions for consideration as digital biomarkers to quantify gait asymmetry.


2020 ◽  
Vol 10 (11) ◽  
pp. 3805 ◽  
Author(s):  
Špela Bogataj ◽  
Maja Pajek ◽  
Slobodan Andrašić ◽  
Nebojša Trajković

This study aimed to examine the reliability, validity, and usefulness of the smartphone-based application, My Jump 2, against Optojump in recreationally active adults. Participants (18 women, 28.9 ± 5.6 years, and 26 men, 30.1 ± 10.6 years) completed squat jumps (SJ), counter-movement jumps (CMJ), and CMJ with arm swing (CMJAS) on Optojump and were simultaneously recorded using My Jump 2. To evaluate concurrent validity, jump height, calculated from flight time attained from each device, was compared for each jump type. Test-retest reliability was determined by replicating data analysis of My Jump 2 recordings on two occasions separated by two weeks. High test-retest reliability (Intraclass correlation coefficient (ICC) > 0.93) was observed for all measures in both male and female athletes. Very large correlations were observed between the My Jump 2 app and Optojump for SJ (r = 0.95, p = 0.001), CMJ (r = 0.98, p = 0.001), and CMJAS (r = 0.98, p = 0.001) in male athletes. Similar results were obtained for female recreational athletes for all jumps (r > 0.94, p = 0.001). The study results suggest that My Jump 2 is a valid, reliable, and useful tool for measuring vertical jump in recreationally active adults. Therefore, due to its simplicity and practicality, it can be used by practitioners, coaches, and recreationally-active adults to measure vertical jump performance with a simple test as SJ, CMJ, and CMJAS.


2020 ◽  
Vol 47 (4) ◽  
pp. 479-486
Author(s):  
Yuki Kondo ◽  
Kyota Bando ◽  
Yosuke Ariake ◽  
Wakana Katsuta ◽  
Kyoko Todoroki ◽  
...  

BACKGROUND: The reliability of the evaluation of the Balance Evaluation Systems Test (BESTest) and its two abbreviated versions are confirmed for balance characteristics and reliability. However, they are not utilized in cases of spinocerebellar ataxia (SCA). OBJECTIVE: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BESTest and its abbreviated versions in persons with mild to moderate spinocerebellar ataxia. METHODS: The BESTest was performed in 20 persons with SCA at baseline and one month later. The scores of the abbreviated version of the BESTest were determined from the BESTest scores. The interclass correlation coefficient (1,1) was used as a measure of relative reliability. Furthermore, we calculated the MDC in the BESTest and its abbreviated versions. RESULTS: The intraclass correlation coefficients (1,1) and MDC at 95% confidence intervals were 0.92, 8.7(8.1%), 0.91, 4.1(14.5%), and 0.81, 5.2(21.6%) for the Balance, Mini-Balance, and Brief-Balance Evaluation Systems Tests, respectively. CONCLUSIONS: The BESTest and its abbreviated versions had high test-retest reliability. The MDC values of the BESTest could enable clinicians and researchers to interpret changes in the balance of patients with SCA more precisely.


Sign in / Sign up

Export Citation Format

Share Document