polymer content
Recently Published Documents


TOTAL DOCUMENTS

165
(FIVE YEARS 40)

H-INDEX

19
(FIVE YEARS 3)

2021 ◽  
Vol 11 (22) ◽  
pp. 10911
Author(s):  
Gang Xu ◽  
Xiaojing Gong ◽  
Yunhong Yu ◽  
Xianhua Chen

The performance of Styrene-butadiene-styrene (SBS) modified asphalt is closely related to the content of SBS modifier. In the production process of modified asphalt, a certain amount of additive such as sulfur and rubber oil may be added to reduce the segregation and promote the swelling of the polymer, but the effect of these additives on determining SBS content in asphalt is not yet clear. This paper presents the calibration curves of SBS content based on rutting factor and creep slope and points out its defects according to the temperature scanning test and the bending beam rheometer test. Subsequently, using Fourier transform infrared spectroscopy (FTIR) for rapid determination of polymer content in SBS modified asphalt based on orthogonal test and then the effects of additives such as asphalt type, SBS content, rubber oil and sulfur on the accuracy of polymer content determination by FTIR were investigated. Moreover, in the orthogonal tests of adding sulfur and rubber oil, the multivariate analysis of variance (MANOVA) was firstly used to analyze the additives influence on the test accuracy of FITR. Results indicated that the influencing degree of different additives is different. The influence of sulfur on the determination accuracy is greater than that of rubber oil. Therefore, the rapid determination method needs further improvement.


2021 ◽  
Author(s):  
Ahmed Mohammed ◽  
Kawan Ghafor ◽  
Wael Mahmood ◽  
Warzer Sarwar ◽  
Lajan Burhan

Abstract In this study, the effect of two water reducer polymers with smooth and rough surfaces on the compression strength of Ordinary Portland cement (OPC) was investigated. Three different initial ratios between water and cement (w/c) 0.5, 0.6, and 1 were used in this study. The amount of polymer contents varied from 0 to 0.06 % (%wt) for the cement paste with initial w/c of 0.5 and the polymer contents ranged between 0 to 0.16% (%wt) for the cement paste with initial w/c of 0.6 and 1 were investigated. SEM test was conducted to identify the impact of polymers on the behavior of cement paste. The compression strength of OPC cement was increased significantly with increasing the polymer contents. Because of a fiber net (netting) around cement paste particle was developed when the polymers were added to the cement paste which leads to decrease the void between the particles, binding the cement particles, therefore, increased the viscosity and compression strength of the cement rapidly. In this analysis, the hardness of cement paste with polymer contents has been evaluated and modeled using four different model technics. More environmentally sustainable construction, and lower cost than conventional building materials and early age strengths of the cement. To overcome the mentioned matter, this study aims to establish systematic multiscale models to predict the compression strength of cement paste containing polymers and to be used by the construction industry with no theoretical restrictions. For that purpose, a wide data a total of 280 tested cement paste modified with polymers, has been conducted, analyzed, and modeled. Linear, Nonlinear regression, M5P-tree, and Artificial Neural Network (ANN) technical approaches were used for the qualifications. In the modeling process, the most relevant parameters affecting the strength of cement paste, i.e. polymer incorporation ratio (0-0.16% of cement's mass), water-to-cement ratio (0.5-1), and curing ages (1 to 28 days). According to the correlation coefficient (R), mean absolute error and the root means a square error, the compression strength of cement paste can be well predicted in terms of w/c, polymer content, and curing time using four various simulation techniques. Among the used approaches and based on the training data set, the model made based on the Non-linear regression, ANN, and M5P-tree models seem to be the most reliable models. The sensitivity investigation concludes that the polymer content is the most dominating parameter for the prediction of the compression strength of cement paste with this data set.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
L. N. Oveshnikov ◽  
S. A. Zav’yalov ◽  
I. N. Trunkin ◽  
D. R. Streltsov ◽  
N. K. Chumakov ◽  
...  

AbstractIn this study, we employed several experimental techniques to investigate structure and magnetic properties of poly(p-xylylene)–MnSb composites synthesized by low-temperature vapor deposition polymerization technique and MnSb films deposited at various temperatures. The presence of MnSb nanocrystallites in the studied films was verified by the results of X-ray diffraction, electron microscopy and Raman spectroscopy studies. The obtained data revealed the formation of Sb-rich sublayer with well-oriented Sb grains near the susbtrate, which seems to act as a buffer for the consequent poly(p-xylylene)–MnSb or MnSb layer growth. Increasing the polymer content results in qualitative change of surface morphology of studied films. At high polymer content the hybrid nanocomposite with MnSb nanoparticles embedded into poly(p-xylylene) matrix is formed. All investigated samples demonstrated detectable ferromagnetic response at room temperature, while the parameters of this response revealed a complex correlation with nominal composition, presented crystal phases and surface morphology of studied films. Estimated values of the Curie temperature of the samples are close to that of bulk MnSb.


2021 ◽  
pp. 036354652110285
Author(s):  
Tony Chen ◽  
Caroline Brial ◽  
Moira McCarthy ◽  
Russell F. Warren ◽  
Suzanne A. Maher

Background: Although polyvinyl alcohol (PVA) implants have been developed and used for the treatment of femoral osteochondral defects, their effect on joint contact mechanics during gait has not been assessed. Purpose/Hypothesis: The purpose was to quantify the contact mechanics during simulated gait of focal osteochondral femoral defects and synthetic PVA implants (10% and 20% by volume of PVA), with and without porous titanium (pTi) bases. It was hypothesized that PVA implants with a higher polymer content (and thus a higher modulus) combined with a pTi base would significantly improve defect-related knee joint contact mechanics. Study Design: Controlled laboratory study. Methods: Four cylindrical implants were manufactured: 10% PVA, 20% PVA, and 10% and 20% PVA disks mounted on a pTi base. Devices were implanted into 8 mm–diameter osteochondral defects created on the medial femoral condyles of 7 human cadaveric knees. Knees underwent simulated gait and contact stresses across the tibial plateau were recorded. Contact area, peak contact stress, the sum of stress in 3 regions of interest across the tibial plateau, and the distribution of stresses, as quantified by tracking the weighted center of contact stress throughout gait, were computed for all conditions. Results: An osteochondral defect caused a redistribution of contact stress across the plateau during simulated gait. Solid PVA implants did not improve contact mechanics, while the addition of a porous metal base led to significantly improved joint contact mechanics. Implants consisting of a 20% PVA disk mounted on a pTi base significantly improved the majority of contact mechanics parameters relative to the empty defect condition. Conclusion: The information obtained using our cadaveric test system demonstrated the mechanical consequences of femoral focal osteochondral defects and provides biomechanical support to further pursue the efficacy of high-polymer-content PVA disks attached to a pTi base to improve contact mechanics. Clinical Relevance: As a range of solutions are explored for the treatment of osteochondral defects, our preclinical cadaveric testing model provides unique biomechanical evidence for the continued investigation of novel solutions for osteochondral defects.


Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3241
Author(s):  
Krzysztof Powała ◽  
Andrzej Obraniak ◽  
Dariusz Heim

The implemented new legal regulations regarding thermal comfort, the energy performance of residential buildings, and proecological requirements require the design of new building materials, the use of which will improve the thermal efficiency of newly built and renovated buildings. Therefore, many companies producing building materials strive to improve the properties of their products by reducing the weight of the materials, increasing their mechanical properties, and improving their insulating properties. Currently, there are solutions in phase-change materials (PCM) production technology, such as microencapsulation, but its application on a large scale is extremely costly. This paper presents a solution to the abovementioned problem through the creation and testing of a composite, i.e., a new mixture of gypsum, paraffin, and polymer, which can be used in the production of plasterboard. The presented solution uses a material (PCM) which improves the thermal properties of the composite by taking advantage of the phase-change phenomenon. The study analyzes the influence of polymer content in the total mass of a composite in relation to its thermal conductivity, volumetric heat capacity, and diffusivity. Based on the results contained in this article, the best solution appears to be a mixture with 0.1% polymer content. It is definitely visible in the tests which use drying, hardening time, and paraffin absorption. It differs slightly from the best result in the thermal conductivity test, while it is comparable in terms of volumetric heat capacity and differs slightly from the best result in the thermal diffusivity test.


Author(s):  
SKM. Pothinathan ◽  
M. Muthukannan ◽  
N. Selvapalam ◽  
S. Christopher Gnanaraj

AbstractIn this study, an endeavor is made to discuss mainly the mechanism, use, and application of polymer modified concrete which is increasing in general fame due to its simplicity, ease of handling, proficiency, and agreeable outcomes. This work explores the impact of adding a new polymer named glycoluril on the mechanical property through the estimation of compression, tension, and flexural strength. Physical properties such as density, sorptivity, and acid resistance were studied to establish the durability of concrete. This examination additionally ponders the impact of polymer in concrete and polymer dosage. Series of concrete mix with 0%, 1%, 2%, 3%, and 4% glycoluril by the mass of binder were prepared, cured, and tested in 7 days and 28 days. Results indicate that there is no adjustment in the workability aspect, however, the improvement of strength factor in compression, tension, and flexure is recorded when compared with the conventional concrete. The experimental results show that by increasing the proportion of glycoluril, the strength of concrete increased up to 3% in addition. In the meantime, the 3% addition provided a higher outcome than the other blend. Further expanding the polymer content marginally decreased the strength. The outcome affirms that the utilization of new polymer in concrete will increase the desired property.


Polymers ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 992
Author(s):  
Suchitha Devadas ◽  
Saja M. Nabat Al-Ajrash ◽  
Donald A. Klosterman ◽  
Kenya M. Crosson ◽  
Garry S. Crosson ◽  
...  

Lignin macromolecules are potential precursor materials for producing electrospun nanofibers for composite applications. However, little is known about the effect of lignin type and blend ratios with synthetic polymers. This study analyzed blends of poly(acrylonitrile-co-methyl acrylate) (PAN-MA) with two types of commercially available lignin, low sulfonate (LSL) and alkali, kraft lignin (AL), in DMF solvent. The electrospinning and polymer blend solution conditions were optimized to produce thermally stable, smooth lignin-based nanofibers with total polymer content of up to 20 wt % in solution and a 50/50 blend weight ratio. Microscopy studies revealed that AL blends possess good solubility, miscibility, and dispersibility compared to LSL blends. Despite the lignin content or type, rheological studies demonstrated that PAN-MA concentration in solution dictated the blend’s viscosity. Smooth electrospun nanofibers were fabricated using AL depending upon the total polymer content and blend ratio. AL’s addition to PAN-MA did not affect the glass transition or degradation temperatures of the nanofibers compared to neat PAN-MA. We confirmed the presence of each lignin type within PAN-MA nanofibers through infrared spectroscopy. PAN-MA/AL nanofibers possessed similar morphological and thermal properties as PAN-MA; thus, these lignin-based nanofibers can replace PAN in future applications, including production of carbon fibers and supercapacitors.


Sign in / Sign up

Export Citation Format

Share Document