lower upper
Recently Published Documents


TOTAL DOCUMENTS

277
(FIVE YEARS 59)

H-INDEX

22
(FIVE YEARS 3)

2021 ◽  
Vol 18 (5) ◽  
Author(s):  
Alessandro Fonda ◽  
Giuliano Klun ◽  
Andrea Sfecci

AbstractWe prove the existence of periodic solutions of some infinite-dimensional systems by the use of the lower/upper solutions method. Both the well-ordered and non-well-ordered cases are treated, thus generalizing to systems some well-established results for scalar equations.


2021 ◽  
Author(s):  
Noreh Rakhsh Khorshid ◽  
Sohrab Ostadhadi-dehkordi

Abstract In this article, we apply rough soft set to a special algebraic hyperstructure, which obtained of disjoint Γ-semihypergroups, and give the concept of rough soft semihypergroup. We propose the notion of lower and upper approximations with respect to a special semihypergroup and obtain some properties of them. Moreover, we consider a connection between lower(upper) approximation of a special semihypergroup and lower(upper) approximation of associated Γ-hypergroupoid. In the last section of this research, we discuss the decision making algorithm of rough soft semihypergroups and we obtain a relation between the decision making algorithm of rough soft semihypergroups and their associated rough soft Γ-hypergroupoid for a special semihypergroup.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Chen-Hao Wang ◽  
Xiao-Min Shi

AbstractStepped impedance resonator (SIR) and its derivative resonators are widely used in the design of microwave filters. However, many spurious modes will be introduced into the stopband, resulting in lower upper stopband suppression and performance degradation. Based on the principle of slit line, a method to enhance the upper stopband suppression is proposed and verified by a miniaturized tri-notched wideband bandpass filter based on stub loaded ring resonator (SLRR) and shorted-stub loaded SIR (SSLSIR). The wideband is formed by coupling SLRR and interdigital lines, which has a rectangular DGS on the back of the substrate. Three notched bands with controllable positions in the passband can be produced by inserting two different SSLSIRs inside and outside the SLRR. Four slit lines are loaded on the low impedance stub of SSLSIR to adjust the high-order modes close to the transmission zeros (TZs). The operating frequency of the filter is 2.2–7.6 GHz, and the three notched bands are located at 2.97 GHz, 5.75 GHz and 6.46 GHz, respectively. The measurement results show that the − 20 dB enhanced upper stopband of the filter can reach 32 GHz, which proves that the filter has the characteristic of ultrawide upper stopband suppression while keeping the miniaturization.


Author(s):  
Alexander Ferko ◽  
Juraj Váňa ◽  
Marek Adámik ◽  
Adam Švec ◽  
Michal Žáček ◽  
...  

AbstractDehiscence of colorectal anastomosis is a serious complication that is associated with increased mortality, impaired functional and oncological outcomes. The hypothesis was that anastomosis reinforcement and vacuum trans-anal drainage could eliminate some risk factors, such as mechanically stapled anastomosis instability and local infection. Patients with rectal cancer within 10 cm of the anal verge and low anterior resection with double-stapled technique were included consecutively. A stapler anastomosis was supplemented by trans-anal reinforcement and vacuum drainage using a povidone-iodine-soaked sponge. Modified reinforcement using a circular mucosa plication was developed and used. Patients were followed up by postoperative endoscopy and outcomes were acute leak rate, morbidity, and diversion rate. The procedure was successfully completed in 52 from 54 patients during time period January 2019–October 2020. The mean age of patients was 61 years (lower–upper quartiles 54–69 years). There were 38/52 (73%) males and 14/52 (27%) females; the neoadjuvant radiotherapy was indicated in a group of patients in 24/52 (46%). The mean level of anastomosis was 3.8 cm (lower–upper quartiles 3.00–4.88 cm). The overall morbidity was 32.6% (17/52) and Clavien–Dindo complications ≥ 3 grade appeared in 3/52 (5.7%) patients. No loss of anastomosis was recorded and no patient died postoperatively. The symptomatic anastomotic leak was recorded in 2 (3.8%) patients and asymptomatic blind fistula was recorded in one patient 1/52 (1.9%). Diversion ileostomy was created in 1/52 patient (1.9%). Reinforcement of double-stapled anastomosis using a circular mucosa plication with combination of vacuum povidone-iodine-soaked sponge drainage led to a low acute leak and diversion rate. This pilot study requires further investigation.Registered at ClinicalTrials.gov.: Trial registration number is NCT04735107, date of registration February 2, 2021, registered retrospectively.


2021 ◽  
pp. 104874
Author(s):  
Yuta Tsukiji ◽  
Xingsheng Jin ◽  
Tianmin Du ◽  
Yoichi Azuma ◽  
Soki Hattori ◽  
...  

2021 ◽  
Vol 17 (64) ◽  
pp. 124-139
Author(s):  
Carlos David Gómez-Carmona ◽  
Alejandro Bastida-Castillo ◽  
Víctor Moreno-Pérez ◽  
Sergio José Ibáñez ◽  
José Pino-Ortega

An association between accelerometer workload and injury risk has been found previously. However, any research has assessed the absorption dynamics of external workload through the measurement in different anatomical locations simultaneously. A cross-sectional study was designed to: (i) to describe the multi-joint external workload profile of youth soccer players, (ii) to identify differences between-participants related to anatomical locations, (iii) to analyze the workload dynamics at different speeds at joints and body segments, (iv) to characterize the multi-joint individual workload and the within-participants difference in each body segment. Twenty-one U-18 male players, that were part of a Youth Spanish First Division soccer team, performed an incremental running treadmill test and wore four WIMU PROTM inertial devices in lower limb (ankle-knee) and spine (lower-upper back) locations to register cumulative tri-axial accelerometry-based workload (PlayerLoad, PLRT). The main results have shown that the highest PLRT was detected at the lower limb, especially at the ankle. Different dynamics of accelerometer workload have been found between lower and upper limb, being them between ankle-knee at 12-km/h and lower-upper back at 9.5-km/h (p<.05). Between-participants’ differences were shown at all joints, finding the highest differences at the upper back (p<.01; d=2.17). Finally, the body segment knee-lower back reported the highest differences (%diff=34.25-to-67.28; d=2.20-to-4.77). In conclusion, a great between-participants external workload variability was found at joints and body segments, being recommended for an individualized assessment and specific training protocols.


Sign in / Sign up

Export Citation Format

Share Document