glucose solution
Recently Published Documents


TOTAL DOCUMENTS

517
(FIVE YEARS 95)

H-INDEX

35
(FIVE YEARS 3)

Energy ◽  
2022 ◽  
pp. 123147
Author(s):  
Zhenbin Chen ◽  
Li Wang ◽  
Zhilong Wei ◽  
Yu Wang ◽  
Jiaojun Deng

2022 ◽  
Vol 2152 (1) ◽  
pp. 012023
Author(s):  
Shuwei Lv ◽  
Xinming Zhang ◽  
Xiaodong Yang ◽  
Ying Zhai

Abstract A chemical etching technique is used to prepare a superhydrophobic surface with a honeycomb rough structure on the aluminum surface. Use SEM, Optical contact angle meter and Surface tension detector to characterize the etched aluminum substrate. After the 8th etching, the surface of the sample showed the morphology of micro/nano-scale honeycomb pores and protrusions, and the water contact angle (WCA) is 135°. After being modified with octadecanethiol methanol solution, WCA is 153.1°. After modification, the contact angle of the sample surface decreases with the increase of the glucose solution concentration. When the glucose solution concentration reaches 1000 mg/L, the superhydrophobicity is lost.


2021 ◽  
Vol 42 (1) ◽  
pp. 343-348
Author(s):  
KAZUKI UCHIYAMA ◽  
YOSHITAKA SAITO ◽  
TATSUHIKO SAKAMOTO ◽  
YOH TAKEKUMA ◽  
YOSHITO KOMATSU ◽  
...  

2021 ◽  
pp. 381-385
Author(s):  
Assunta PATANO ◽  
Daniela DI VENERE ◽  
Sabino CECI ◽  
Pula BERATE ◽  
Sebastian CANDREA ◽  
...  

Introduction. Burning mouth syndrome (BMS) is a clinical condition characterized by the presence of chronic pain in absence of clinically visible lesions of the oral mucosa. The etiology is uncertain and the therapeutic strategies still controversial. The objective of this prospective study is to analyze the efficacy of essential oils-based mouthwashes in the therapy of BMS. Material and method. This study included 16 patients affected by BMS who were treated with essential oils-based mouthwashes and glucose solution on alternated days for 30 days. Symptomatology was evaluated after 15, 30 and 90 days. Results and discussions. A the end of the treatment, most of the patients (67%) referred an improvement of symptoms up to complete remission in 90 days. Conclusions. Based on this study, essential oils-based mouthwashes could represent a valid aid in the treatment of BMS. Further studies are necessary in order to identify effective and standardized therapeutic protocols. Keywords: Burning Mouth Syndrome; oral rinse; essential oils; therapeutic strategies,


2021 ◽  
Vol 11 ◽  
Author(s):  
Alberto Testori ◽  
Gianluca Perroni ◽  
Marco Alloisio ◽  
Emanuele Voulaz ◽  
Veronica Maria Giudici ◽  
...  

BackgroundPersistent air leak is a common complication occurring from 6% to 23% of cases after extended pleurectomy/decortication for malignant pleural mesothelioma. Treatment options for this complication after major lung resection are well documented in literature; nevertheless, lines of evidence in extended pleurectomy/decortication for malignant pleural mesothelioma are absent. The aim of the study is to evaluate the efficacy of intraoperative administration of 50% hypertonic glucose solution in reducing duration of air leak following extended pleurectomy/decortication for malignant pleural mesothelioma.Materials and MethodsIn this retrospective case–control study, we analyzed our electronic health record and selected those patients with a histological diagnosis of malignant pleural mesothelioma who underwent extended pleurectomy/decortication in the period 2013–2021. From 2018, we introduced a lavage with 500 ml of glucose solution at 50% concentration into the chest cavity at the end of the surgical procedure. Patients operated before 2018 were used as the control group. Postoperative glycemia was measured, and patients were followed after hospital discharge until the air leak resolved and the chest tube was removed. Statistical analysis was performed using R software.ResultsA total of 71 patients met our criteria. Treatment and control groups were similar for age, sex, smoking status, number of comorbidities, tumor histotype, and side of disease. Use of hypertonic glucose solution resulted in shorter chest tube maintenance after hospital discharge (p = 0.0028). A statistically significant difference (p = 0.02) was also found in postoperative glycemia between the treatment (103 g/dl ± 8.9) and control group (98.8 g/dl ± 8.6). Days of hospitalization and chest tube maintenance during hospitalization did not significantly differ between the groups.InterpretationIntraoperative administration of 50% hypertonic glucose solution reduced the duration of air leak after hospital discharge. An increase in postoperative glycemia was found in the treatment group, but with no clinical effect. Hypertonic glucose solution is an effective and safe method to manage persistent air leak after extended pleurectomy/decortication for malignant pleural mesothelioma.


Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 484
Author(s):  
Yangchuan Ma ◽  
Tian Qiang ◽  
Minjia Gao ◽  
Junge Liang ◽  
Yanfeng Jiang

Here, we propose a glucose biosensor with the advantages of quantification, excellent linearity, temperature-calibration function, and real-time detection based on a resistor and capacitor, in which the resistor works as a temperature sensor and the capacitor works as a biosensor. The resistor has a symmetrical meandering type structure that increases the contact area, leading to variations in resistance and effective temperature monitoring of a glucose solution. The capacitor is designed with an intertwined structure that fully contacts the glucose solution, so that capacitance is sensitively varied, and high sensitivity monitoring can be realized. Moreover, a polydimethylsiloxane microfluidic channel is applied to achieve a fixed shape, a fixed point, and quantitative measurements, which can eliminate influences caused by fluidity, shape, and thickness of the glucose sample. The glucose solution in a temperature range of 25–100 °C is measured with variations of 0.2716 Ω/°C and a linearity response of 0.9993, ensuring that the capacitor sensor can have reference temperature information before detecting the glucose concentration, achieving the purpose of temperature calibration. The proposed capacitor-based biosensor demonstrates sensitivities of 0.413 nF/mg·dL−1, 0.048 nF/mg·dL−1, and 0.011 pF/mg·dL−1; linearity responses of 0.96039, 0.91547, and 0.97835; and response times less than 1 second, respectively, at DC, 1 kHz, and 1 MHz for a glucose solution with a concentration range of 25–1000 mg/dL.


Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 480
Author(s):  
Minjia Gao ◽  
Tian Qiang ◽  
Yangchuan Ma ◽  
Junge Liang ◽  
Yanfeng Jiang

Due to the increasing number of diabetic patients, early monitoring of glucose levels is particularly important; therefore, glucose biosensors have attracted enormous attention from researchers. In this paper, we propose a glucose microwave biosensor based on RFID and achieve a non-contact measurement of the concentration of glucose solutions. The Reader is a complementary split-ring resonator (CSRR), and the Tag is comprised of a squared spiral capacitor (SSC). A polydimethylsiloxane microfluidic quantitative cavity with a volume of 1.56 μL is integrated on the Tag to ensure that the glucose solution can be accurately set to the sensitive area and fully contacted with the electromagnetic flux. Because the SSC exhibits different capacitances when it contacts glucose solutions of different concentrations, changing the resonant frequency of the CSRR, we can use the relationship to characterize the biosensing response. Measurement results show that bare CSRR and RFID-based biosensors have achieved sensitivities of 0.31 MHz/mg·dL−1 and 10.27 kHz/mg·dL−1, and detection limits of 13.79 mg/dL and 1.19 mg/dL, respectively, and both realize a response time of less than 1 s. Linear regression analysis of the abovementioned biosensors showed an excellent linear relationship. The proposed design provides a feasible solution for microwave biosensors aiming for the non-contact measurement of glucose concentration.


Electronics ◽  
2021 ◽  
Vol 10 (23) ◽  
pp. 2930
Author(s):  
Giovanni Buonanno ◽  
Adriana Brancaccio ◽  
Sandra Costanzo ◽  
Raffaele Solimene

This paper sets out a method for improving the resolution of resonant microwave sensors. Usually, the frequency response of these devices is associated with a low quality factor, and consequently with a low resolution in terms of tracking capacity of the resonance frequency shift. Furthermore, since only a finite number of samples can be acquired during the measurement process, the “true” resonance frequency may not be included in the set of acquired data. In order to have an accurate estimate of the resonance frequency, high performance systems with very fine frequency sampling are thus required. To limit these drawbacks, an iterative algorithm is presented which aims to refine the response of resonant microwave sensors by means of a suitable post-processing. The algorithm evaluation is first carried out on synthetic data, and then applied on experimental data referring to a practical scenario, which is inherent to return loss measurements performed by a microwave patch antenna immersed in a water-glucose solution with different concentrations.


Nanomaterials ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 2961
Author(s):  
Jana Kubacková ◽  
Cyril Slabý ◽  
Denis Horvath ◽  
Andrej Hovan ◽  
Gergely T. Iványi ◽  
...  

Photopolymer nanowires prepared by two-photon polymerization direct laser writing (TPP-DLW) are the building blocks of many microstructure systems. These nanowires possess viscoelastic characteristics that define their deformations under applied forces when operated in a dynamic regime. A simple mechanical model was previously used to describe the bending recovery motion of deflected nanowire cantilevers in Newtonian liquids. The inverse problem is targeted in this work; the experimental observations are used to determine the nanowire physical characteristics. Most importantly, based on the linear three-parameter solid model, we derive explicit formulas to calculate the viscoelastic material parameters. It is shown that the effective elastic modulus of the studied nanowires is two orders of magnitude lower than measured for the bulk material. Additionally, we report on a notable effect of the surrounding aqueous glucose solution on the elasticity and the intrinsic viscosity of the studied nanowires made of Ormocomp.


Sign in / Sign up

Export Citation Format

Share Document