current reference
Recently Published Documents


TOTAL DOCUMENTS

454
(FIVE YEARS 97)

H-INDEX

25
(FIVE YEARS 5)

2021 ◽  
Author(s):  
Jing Wang ◽  
Xuan Sun ◽  
Wei Sun ◽  
Chen Deng ◽  
Lin Cheng
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7464
Author(s):  
Hyun-Jae Lee ◽  
Jin-Geun Shon

This paper presents an improved voltage flux-weakening strategy of a permanent magnet synchronous motor (PMSM) in a high-speed operation. The speed control performance using voltage flux-weakening control is not affected by the motor parameters, so it is used in various motors for high-speed operations. In general, the voltage flux-weakening control uses voltage references to generate a flux axis current reference. However, there may be errors between the voltage reference and the actual voltage flowing into the motor. This causes an error in the current reference generation and reduces the efficiency of the inverter and motor due to the use of more current. In this paper, the problems that can occur due to voltage errors were analyzed through theoretical approaches and simulations, and improved voltage flux-weakening control to resolve these problems was presented. This method’s advantage is that the error between the voltage reference and the voltage applied to the motor can be minimized, and the target speed can be reached with minimum current. As a result, it was possible to increase the energy efficiency by reducing the amount of current flowing through the motor. The effect of the improved voltage-based flux-weakening control method was verified through simulations and experiments. As a result, the voltage errors were reduced by approximately 2.16% compared to the general method. Moreover, the current used in the field-weakening control region was reduced by up to 27.17% under the same torque condition.


Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5236
Author(s):  
Xiangwu Yan ◽  
Baixue Liang ◽  
Jiaoxin Jia ◽  
Waseem Aslam ◽  
Chenguang Wang ◽  
...  

Due to a limitation in the magnitude of the three-phase output inverter currents, the output active power of the photovoltaic (PV) unit has been de-rated during low voltage ride through, which brings great instability risk to the power system. With the increase in the penetration rate of new energy, the impact of the power shortage on the system transient stability increases. It is of great significance to analyze the impact of this transient power shortage on system stability. This article explores methods to improve the active power output capability of photovoltaic units during low-breakthrough periods. A transient simulation model of a grid-connected PV generator with low-voltage ride-through (LVRT) capability is presented, under the condition of meeting the overcurrent capacity of the PV inverter and the requirement of dynamic reactive power support supplied by the PV generator specified in the China grid codes (GB/T 19964-2012) during grid fault. An example system with high PV penetration is built. The change principle and influencing factors of PV transient active power output are analyzed. The simulation model is designed in PowerFactory/DIgSILENT, and several types of three-phase voltage sags are performed in simulation to assess the impact of the active current reference calculation method and the maximum inverter output current (Imax) limit value on the PV active power output. According to the three indexes, namely the maximum active power of PV unit during the fault, the power improvement gradient and the power surge after the fault is cleared. Simulation results showed that using the orthogonal decomposition method to calculate the active current reference can make full use of the current capacity of the converter. Setting Imax to 1.1 rated current of photovoltaic inverter (IN) can reduce the cost-effectiveness ratio of the transient active power output of the PV unit. Therefore, we aim to improve the unit’s transient active power output capacity and realize the optimal effect of improving the transient active power shortage of the system.


Author(s):  
Tianxing Li ◽  
Ruiqing Ma ◽  
Hao Bai ◽  
Ping Fan ◽  
Yuchen Zhang

The injection of a third harmonic current can improve the electromagnetic torque output of the five-phase permanent magnet synchronous motor. In this paper, constant copper consumption and constant maximum current are used as constraints, and the influence of the ratio between the third harmonic current and the fundamental current on the electromagnetic torque under the two constraints is analyzed. The electromagnetic torque is the largest when the third harmonic current reference value is equal to the fundamental current reference value of ψf3/ψf times under the premise of the constant copper loss. On the premise that the maximum current is constant, the electromagnetic torque is the largest when the third harmonic current reference value is equal to the fundamental current reference value of kw/(6kw-kw3/3) times. On this basis, according to the vector amplitude, phase and action time, the changing trends of maximum voltage utilization rate with Vref3/Vref1 under three different kinds of methods are given. Finally, through the experimental platform, the control effects of the three kinds of SVPWM are compared under two constraint conditions.


Electronics ◽  
2021 ◽  
Vol 10 (12) ◽  
pp. 1470
Author(s):  
Mahdi Shahparasti ◽  
Amirhossein Rajaei ◽  
Andres Tarraso ◽  
Jose David Vidal Leon Romay ◽  
Alvaro Luna

This paper presents a proposal for potential bioelectrochemical power to gas stations. It consists of a two-level voltage source converter interfacing the electrical grid on the AC side and an electromethanogenesis based bioelectrochemical system (EMG-BES) working as a stacked module on the DC side. The proposed system converts CO2 and electrical energy into methane, using wastewater as the additional chemical energy input. This energy storage system can contribute to dampening the variability of renewables in the electrical network, provide even flexibility and grid services by controlling the active and reactive power exchanged and is an interesting alternative technology in the market of energy storage for big energy applications. The big challenge for controlling this system lays in the fact that the DC bus voltage of the converter has to be changed in order to regulate the exchanged active power with the grid. This paper presents a cascade approach to control such a system by means of combining external control loops with fast inner loops. The outer power loop, with a proportional-integral (PI) controller with special limitation values and anti-windup capability, is used to generate DC bus voltage reference. An intermediate loop is used for DC bus voltage regulation and current reference generation. A new proportional resonant controller is used to track the current reference. The proposed scheme has been validated through real-time simulation in OPAL OP4510.


2021 ◽  
Vol 64 (6) ◽  
pp. 310-318
Author(s):  
I. M. Vikulin ◽  
L. F. Vikulina ◽  
V. E. Gorbachev ◽  
N. S. Mikhailov

Sign in / Sign up

Export Citation Format

Share Document