small aerosol
Recently Published Documents


TOTAL DOCUMENTS

38
(FIVE YEARS 4)

H-INDEX

10
(FIVE YEARS 1)

Viruses ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 598
Author(s):  
Maren Bormann ◽  
Mira Alt ◽  
Leonie Schipper ◽  
Lukas van de Sand ◽  
Mona Otte ◽  
...  

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is transmitted from person to person by close contact, small aerosol respiratory droplets, and potentially via contact with contaminated surfaces. Herein, we investigated the effectiveness of commercial UVC-LED disinfection boxes in inactivating SARS-CoV-2-contaminated surfaces of personal items. We contaminated glass, metal, and plastic samples representing the surfaces of personal items such as smartphones, coins, or credit cards with SARS-CoV-2 formulated in an organic matrix mimicking human respiratory secretions. For disinfection, the samples were placed at different distances from UVC emitting LEDs inside commercial UVC-LED disinfection boxes and irradiated for different time periods (up to 10 min). High viral loads of SARS-CoV-2 were effectively inactivated on all surfaces after 3 min of irradiation. Even 10 s of UVC-exposure strongly reduced viral loads. Thus, UVC-LED boxes proved to be an effective method for disinfecting SARS-CoV-2-contaminated surfaces that are typically found on personal items.


2021 ◽  
Author(s):  
Maren Bormann ◽  
Mira Alt ◽  
Leonie Schipper ◽  
Lukas van de Sand ◽  
Mona Otte ◽  
...  

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is transmitted from person-to-person by close contact, small aerosol respiratory droplets and potentially via contact with contaminated surfaces. Here, we investigated the effectiveness of commercial UVC-LED disinfection boxes in inactivating SARS-CoV-2 contaminated surfaces of personal items. We contaminated glass, metal and plastic samples representing the surfaces of personal items such as smartphones, coins or credit cards with SARS-CoV-2 formulated in an organic matrix mimicking human respiratory secretions. For disinfection, the samples were placed at different distances from UVC emitting LEDs inside commercial UVC-LED disinfection boxes and irradiated for different time periods (up to 10 minutes). High viral loads of SARS-CoV-2 were effectively inactivated on all surfaces after 3 minutes of irradiation. Even 10 seconds of UVC-exposure strongly reduced viral loads. Thus, UVC-LED boxes proved to be an effective method for disinfecting SARS-CoV-2 contaminated surfaces that are typically found on personal items.


2020 ◽  
Author(s):  
William G. Lindsley ◽  
Francoise M. Blachere ◽  
Brandon F. Law ◽  
Donald H. Beezhold ◽  
John D. Noti

AbstractFace masks are recommended to reduce community transmission of SARS-CoV-2. One of the primary benefits of face masks and other coverings is as source control devices to reduce the expulsion of respiratory aerosols during coughing, breathing, and speaking. Face shields and neck gaiters have been proposed as an alternative to face masks, but information about face shields and neck gaiters as source control devices is limited. We used a cough aerosol simulator with a pliable skin headform to propel small aerosol particles (0 to 7 µm) into different face coverings. An N95 respirator blocked 99% of the cough aerosol, a medical grade procedure mask blocked 59%, a 3-ply cotton cloth face mask blocked 51%, and a polyester neck gaiter blocked 47% as a single layer and 60% when folded into a double layer. In contrast, the face shield blocked 2% of the cough aerosol. Our results suggest that face masks and neck gaiters are preferable to face shields as source control devices for cough aerosols.


2019 ◽  
Author(s):  
Franz Friebel ◽  
Prem Lobo ◽  
David Neubauer ◽  
Ulrike Lohmann ◽  
Saskia Drossaart van Dusseldorp ◽  
...  

Abstract. The largest contributors to the uncertainty in assessing the anthropogenic contribution in radiative forcing are the direct and indirect effects of aerosol particles on the Earth's radiative budget. Soot particles are of special interest since their properties can change significantly due to aging processes once they are emitted to the atmosphere. Probably the largest obstacle for the investigation of these processes in the laboratory is the long atmospheric lifetime of one week, demanding tailored experiments that cover this time span. This work presents results on the ability of two types of soot to act as cloud condensation nuclei (CCN) after exposure to atmospherically relevant levels of ozone and humidity. Aging times of up to 12 h were achieved by successful application of the continuous-flow stirred tank reactor (CSTR) concept while allowing for size-selection of particles prior to the aging step. 100 nm particles rich in organic carbon (OC) that were initially CCN-inactive showed significant CCN-activity at supersaturations (SS) down to 0.3 % after 10 h of exposure to 200 ppb of ozone. While this process was not affected by different levels of relative humidity in the range 5–75 %, a high sensitivity towards the ambient/reaction temperature was observed. Soot particles with a lower OC-content demanded an approximately four-fold longer aging duration to show CCN-activity for the same SS. Prior to the slow change in the CCN-activity, a rapid increase in the particle diameter was detected which occurred within several minutes. This study highlights the applicability of the CSTR-approach for the simulation of atmospheric aging processes, as aging durations beyond 12 h can be achieved in comparably small aerosol chamber volumes (


2018 ◽  
Author(s):  
Mario Nachbar ◽  
Henrike Wilms ◽  
Denis Duft ◽  
Tasha Aylett ◽  
Kensei Kitajima ◽  
...  

Abstract. Mean temperatures in the polar summer mesopause can drop to 130 K. The cold temperatures in combination with water vapor mixing ratios of a few parts per million give rise to the formation of ice particles. These ice particles may be observed as polar mesospheric clouds. Mesospheric ice cloud formation is believed to initiate heterogeneously on small aerosol particles (r 


2017 ◽  
Vol 17 (10) ◽  
pp. 2358-2366 ◽  
Author(s):  
Wenming Yang ◽  
Rong Zhu ◽  
Chao Zhang ◽  
Zheng Li

2016 ◽  
Author(s):  
John Backman ◽  
Lauren Schmeisser ◽  
Aki Virkkula ◽  
John A. Ogren ◽  
Eija Asmi ◽  
...  

Abstract. Several types of filter-based instruments are used to estimate aerosol light absorption coefficients.Two significant results are presented based on Aethalometer measurements at six Arctic station from 2012–2014. First, an alternative method of post-processing the Aethalometer data is presented which reduces measurement noise and lowers the detection limit of the instrument more effectively than boxcar averaging. The biggest benefit of this approach can be achieved if instrument drift is minimized. Moreover, by using an attenuation threshold criterion for data post-processing, the relative uncertainty from the electronic noise the instrument is kept constant. This approach results in a time series with a variable collection time (Δt), but with a constant relative uncertainty with regard to electronic noise in the instrument. An additional advantage of this method is that the detection limit of the instrument will be lowered at small aerosol concentrations at the expense of temporal resolution, whereas there is little to no loss in temporal resolution at high aerosol concentrations (>2.1–6.7 Mm−1 as measured by the Aethalometers). At high aerosol concentrations, minimizing the detection limit of the instrument is less critical. Second, utilizing co-located reference methods of aerosol absorption, a multiple cattering enhancement factor (Cref) of 3.10 specific to low elevation Arctic stations is found. Cref is a fundamental part of most of the Aethalometer corrections available in literature, and this is the first time a Cref value has been obtained for the Arctic.


2016 ◽  
Vol 9 (4) ◽  
pp. 1721-1742 ◽  
Author(s):  
Jean-Baptiste Renard ◽  
François Dulac ◽  
Gwenaël Berthet ◽  
Thibaut Lurton ◽  
Damien Vignelles ◽  
...  

Abstract. The study of aerosols in the troposphere and in the stratosphere is of major importance both for climate and air quality studies. Among the numerous instruments available, optical aerosol particles counters (OPCs) provide the size distribution in diameter range from about 100 nm to a few tens of µm. Most of them are very sensitive to the nature of aerosols, and this can result in significant biases in the retrieved size distribution. We describe here a new versatile optical particle/sizer counter named LOAC (Light Optical Aerosol Counter), which is light and compact enough to perform measurements not only at the surface but under all kinds of balloons in the troposphere and in the stratosphere. LOAC is an original OPC performing observations at two scattering angles. The first one is around 12°, and is almost insensitive to the refractive index of the particles; the second one is around 60° and is strongly sensitive to the refractive index of the particles. By combining measurement at the two angles, it is possible to retrieve the size distribution between 0.2 and 100 µm and to estimate the nature of the dominant particles (droplets, carbonaceous, salts and mineral particles) when the aerosol is relatively homogeneous. This typology is based on calibration charts obtained in the laboratory. The uncertainty for total concentrations measurements is ±20 % when concentrations are higher than 1 particle cm−3 (for a 10 min integration time). For lower concentrations, the uncertainty is up to about ±60 % for concentrations smaller than 10−2 particle cm−3. Also, the uncertainties in size calibration are ±0.025 µm for particles smaller than 0.6 µm, 5 % for particles in the 0.7–2 µm range, and 10 % for particles greater than 2 µm. The measurement accuracy of submicronic particles could be reduced in a strongly turbid case when concentration of particles > 3 µm exceeds a few particles  cm−3. Several campaigns of cross-comparison of LOAC with other particle counting instruments and remote sensing photometers have been conducted to validate both the size distribution derived by LOAC and the retrieved particle number density. The typology of the aerosols has been validated in well-defined conditions including urban pollution, desert dust episodes, sea spray, fog, and cloud. Comparison with reference aerosol mass monitoring instruments also shows that the LOAC measurements can be successfully converted to mass concentrations.


2015 ◽  
Vol 8 (9) ◽  
pp. 9993-10056 ◽  
Author(s):  
J.-B. Renard ◽  
F. Dulac ◽  
G. Berthet ◽  
T. Lurton ◽  
D. Vignelles ◽  
...  

Abstract. The study of aerosols in the troposphere and in the stratosphere is of major importance both for climate and air quality studies. Among the numerous instruments available, aerosol particles counters provide the size distribution in diameter range from few hundreds of nm to few tens of μm. Most of them are very sensitive to the nature of aerosols, and this can result in significant biases in the retrieved size distribution. We describe here a new versatile optical particle/sizer counter (OPC) named LOAC (Light Optical Aerosol Counter), which is light and compact enough to perform measurements not only at the surface but under all kinds of balloons in the troposphere and in the stratosphere. LOAC is an original OPC performing observations at two scattering angles. The first one is around 12°, and is almost insensitive to the nature of the particles; the second one is around 60° and is strongly sensitive to the refractive index of the particles. By combining measurement at the two angles, it is possible to retrieve accurately the size distribution and to estimate the nature of the dominant particles (droplets, carbonaceous, salts and mineral particles) in several size classes. This topology is based on calibration charts obtained in the laboratory. Several campaigns of cross-comparison of LOAC with other particle counting instruments and remote sensing photometers have been conducted to validate both the size distribution derived by LOAC and the retrieved particle number density. The topology of the aerosols has been validated in well-defined conditions including urban pollution, desert dust episodes, fog, and cloud. Comparison with reference aerosol mass monitoring instruments also shows that the LOAC measurements can be successfully converted to mass concentrations. All these tests indicate that no bias is present in the LOAC measurements and in the corresponding data processing.


Sign in / Sign up

Export Citation Format

Share Document