decontamination factor
Recently Published Documents


TOTAL DOCUMENTS

59
(FIVE YEARS 9)

H-INDEX

4
(FIVE YEARS 0)

Polymers ◽  
2021 ◽  
Vol 13 (22) ◽  
pp. 3999
Author(s):  
Gabriela Toader ◽  
Aurel Diacon ◽  
Traian Rotariu ◽  
Mioara Alexandru ◽  
Edina Rusen ◽  
...  

In the context of imminent threats concerning biological and chemical warfare agents, the aim of this study was the development of a new method for biological and chemical decontamination, employing non-toxic, film-forming, water-based biodegradable solutions, using a nano sized reagent together with bentonite as trapping agents for the biological and chemical contaminants. Bentonite-supported nanoparticles of Cu, TiO2, and Ag were successfully synthesized and dispersed in a polyvinyl alcohol (PVA)/glycerol (GLY) aqueous solution. The decontamination effectiveness of the proposed solutions was evaluated by qualitative and quantitative analytical techniques on various micro-organisms, with sulfur mustard (HD) and dimethyl methylphosphonate (DMMP) as contaminants. The results indicate that the peelable active nanocomposite films can be successfully used on contaminated surfaces to neutralize and entrap the hazardous materials and their degradation products. Mechanical and thermal characterization of the polymeric films was also performed to validate the decontamination solution’s potential as peelable-film generating materials. The removal efficacy from the contaminated surfaces for the tested micro-organisms varied between 93% and 97%, while for the chemical agent HD, the highest decontamination factor obtained was 90.89%. DMMP was almost completely removed from the contaminated surfaces, and a decontamination factor of 99.97% was obtained.



2021 ◽  
Vol 11 (1) ◽  
Author(s):  
I. Kajan ◽  
S. Heinitz ◽  
K. Kossert ◽  
P. Sprung ◽  
R. Dressler ◽  
...  

AbstractThis work presents the first direct measurement of the 93Mo half-life. The measurement is a combination of high-resolution mass spectrometry for the determination of the 93Mo concentration and liquid scintillation counting for determining the specific activity. A 93Mo sample of high purity was obtained from proton irradiated niobium by chemical separation of molybdenum with a decontamination factor larger than 1.6 × 1014 with respect to Nb. The half-life of 93Mo was deduced to be 4839(63) years, which is more than 20% longer than the currently adopted value, whereas the relative uncertainty could be reduced by a factor of 15. The probability that the 93Mo decays to the metastable state 93mNb was determined to be 95.7(16)%. This value is a factor of 8 more precise than previous estimations. Due to the man-made production of 93Mo in nuclear facilities, the result leads to significantly increased precision for modelling the low-level nuclear waste composition. The presented work demonstrates the importance of chemical separations in combination with state-of-the-art analysis techniques, which are inevitable for precise and accurate determinations of nuclear decay data.



Processes ◽  
2021 ◽  
Vol 9 (10) ◽  
pp. 1725
Author(s):  
Hee-Chul Eun ◽  
Na-On Chang ◽  
Wang-Kyu Choi ◽  
Sang-Yoon Park ◽  
Seon-Byeong Kim ◽  
...  

It is very important to minimize the waste generation for decontamination of the reactor coolant system in a nuclear facility. As an alternative to commercial decontamination technologies, an inorganic acid chemical decontamination (SP-HyBRID) process can be effectively applied to the decontamination because it can significantly reduce the waste generation. In this study, the decontamination of a contaminated reactor coolant pump shaft from a nuclear facility was conducted using the SP-HyBRID process. First, equipment for a mock-up test of the decontamination was prepared. Detailed experimental conditions for the decontamination were determined through the mock-up test. Under the detailed conditions, the contaminated shaft was successfully decontaminated. The dose rate on the shaft surface was greatly reduced from 1400 to 0.9 μSv/h, and the decontamination factor showed a very high value (>1500).



2021 ◽  
Vol 9 ◽  
Author(s):  
L. W. He ◽  
Y. X. Li ◽  
Y. Zhou ◽  
S. Chen ◽  
L. L. Tong ◽  
...  

During a nuclear power plant severe accident, discharging gas mixture into the spent-fuel pool is an alternative containment depressurization measurement through which radioactive aerosols can be scrubbed. However, it is necessary to develop a code for analyzing the decontamination factor of aerosol pool scrubbing. This article has established the analysis model considering key aerosol pool scrubbing mechanisms and introduced the Akita bubble size relationship. In addition, a code for evaluating the decontamination factor of aerosol pool scrubbing was established. The Advanced Containment Experiment and Light Water Reactor Advanced Containment Experiment were simulated with the code considering different bubble sizes of the Akita model and MELCOR default value to verify the suitability of the Akita bubble size model for simulating aerosol pool scrubbing. Furthermore, the simulation results were compared with the results analyzed by MELCOR code and COCOSYS code from literature, and equivalent predictive ability was observed. In addition, a sensitivity analysis on bubble size was conducted, and the contribution of different behaviors and mechanisms has been discussed. Finally, the bubble breakup equation was revised and verified with the conditions of the multi-hole bubbler in the Advanced Containment Experiment and Light Water Reactor Advanced Containment Experiment.



2021 ◽  
Vol 7 (1) ◽  
pp. 28-36
Author(s):  
Quynh Luong Pham ◽  
Hoang Lan Nguyen ◽  
Van Chinh Nguyen ◽  
Huu Anh Vuong ◽  
Cao Nguyen Luu ◽  
...  

The development of cesium selective adsorbent is urgent subject for the decontamination of intermediate and high level water from nuclear facilities especially in nuclear accidents. For the selective adsorption and stable immobilization of radioactive cesium, K-Ni- hexacyanoferrate (II) loaded zeolite (FCzeolite) (synthesized zeolite of Hanoi University of Science and Technology) were prepared by impregnation/precipitation method. The ion exchange equilibrium of Cs+ for composites FC-zeolite was attained within 5 h and estimated to be above 97% in Cs+ 100mg/l solution at pH: 4-10. Ion exchange capacity of Cs+ ions (Qmax) for FC-zeoliteX was reached 158.7 and 98.0 mg/g in pure water and sea water respectively.Those values for FC-zeolite A was 103.1 and 63.7 mg/g. Decontamination factor (DF) of FC-zeolite X for 134Cs was 149.7 và 107.5 in pure water and sea water respectively. Initial radioactivity of 134Cs ion solution infect to decontamination factor. KNiFC-zeolite X after uptaked Cs (CsFC- zeolite X) was solidificated in optimal experimental conditions: Mixing CsFC-zeolite X with additive of Na2B4O7 (5%), temperature calcined 900oC for 2h in air. Solid forms was determined some of parameters: Cs immobilization, mechanical stability, volume reduction after calcination (%) and leaching rate of Cs+ ions in solution.



2021 ◽  
Vol 9 ◽  
Author(s):  
Yuxiang Li ◽  
Lili Tong ◽  
Xuewu Cao

During the process of containment depressurization venting, a high-temperature and high-pressure carrier gas with aerosol may be released into the spent fuel pool by a multihole injector. This aerosol in the carrier gas can be removed by pool scrubbing. A small-scale pool scrubbing facility was built to study the aerosol pool scrubbing phenomenon using a multihole injector. In this study, a gaseous mixture of nitrogen and steam is used to simulate a carrier gas, and insoluble solid particles of TiO2 are used to simulate aerosols in the carrier gas. Seven tests were performed to examine the dependence of the decontamination factor (DF) on the pool depth, particle diameter, and steam mass fraction. The results show that log(1/(1–Xm)) has a linear relationship with log(DF). DF varies exponentially with the pool depth, which has an influence on the retention of aerosols with a larger particle diameter. Particle diameters in the range of 0.2–0.52 μm have little effect on the DF. For a low-depth pool scrubbing, the steam condensation mechanism is dominant and the particle diameter does not have a significant effect on the DF. Moreover, the pool scrubbing model is discussed, and an empirical correlation is proposed to evaluate the DF of a pool.



Author(s):  
Muhammad Aadil ◽  
Rab Nawaz ◽  
Ajmal Shah ◽  
Kamran Rasheed Qureshi

Abstract This research presents numerical study of deposition efficiency and decontamination factor of radioactive nuclide in steam generator tubes of a typical 325 MWe PWR. To find out the deposition of aerosol, the discrete phase model (DPM) has been used. The flow has been characterized as compressible, adiabatic, turbulent and wall bounded. When steam generator tube gets ruptured, the radioactive nuclides can escape from primary side and create a radioactive field in the secondary side. This can be harmful for the personnel working at the plant. Therefore, in order to ensure the safety of the plant and personnel, it is important to study the particles deposition on the wall of steam generator tubes. In the present study, a CFD methodology has been first developed and validated with the published results. After methodology validation, it has been applied to the U-tube of a typical PWR steam generator. It has been observed that due to the action of centrifugal force near the bent, the velocity magnitude is high towards the inner wall and the flow separates at the bent entrance. Furthermore, the flow inside the tube is rotational with vortices throughout the domain due to the presence of the bent. Finally, the deposition efficiency and decontamination factor have been calculated and it has been observed that both increase with the increase in particle size due to inertial effects.







Sign in / Sign up

Export Citation Format

Share Document