recombinant nucleocapsid protein
Recently Published Documents


TOTAL DOCUMENTS

58
(FIVE YEARS 11)

H-INDEX

14
(FIVE YEARS 1)

Author(s):  
Maryam Ranjbar ◽  
Marzieh Asadi ◽  
Marjan Nourigorji ◽  
Bahador Sarkari ◽  
Zohreh Mostafavi‐Pour ◽  
...  

Author(s):  
Misbah Tariq ◽  
Jian Hur ◽  
Jun-Won Seo ◽  
Da Young Kim ◽  
Na Ra Yun ◽  
...  

At present, the principal diagnostic methods for COVID-19 comprise the identification of viral nucleic acid by genetic approaches, including PCR-based techniques or next-generation sequencing. However, there is an urgent need for validated serological assays which are crucial for the understanding of immune responses against SARS-CoV-2.


Author(s):  
Pierre Nsele Mutantu ◽  
Mya Myat Ngwe Tun ◽  
Takeshi Nabeshima ◽  
Fuxun Yu ◽  
Patrick Kakoni Mukadi ◽  
...  

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the causative agent of coronavirus disease 2019 (COVID-19). Real-time RT-PCR is the most commonly used method for COVID-19 diagnosis. However, serological assays are urgently needed as complementary tools to RT-PCR. Hachim et al. 2020 and Burbelo et al. 2020 demonstrated that anti-nucleocapsid(N) SARS-CoV-2 antibodies are higher and appear earlier than the spike antibodies. Additionally, cross-reactive antibodies against N protein are more prevalent than those against spike protein. We developed a less cross-reactive immunoglobulin G (IgG) indirect ELISA by using a truncated recombinant SARS-CoV-2 N protein as assay antigen. A highly conserved region of coronaviruses N protein was deleted and the protein was prepared using an E. coli protein expression system. A total of 177 samples collected from COVID-19 suspected cases and 155 negative control sera collected during the pre-COVID-19 period were applied to evaluate the assay’s performance, with the plaque reduction neutralization test and the commercial SARS-CoV-2 spike protein IgG ELISA as gold standards. The SARS-CoV-2 N truncated protein-based ELISA showed similar sensitivity (91.1% vs. 91.9%) and specificity (93.8% vs. 93.8%) between the PRNT and spike IgG ELISA, as well as also higher specificity compared to the full-length N protein (93.8% vs. 89.9%). Our ELISA can be used for the diagnosis and surveillance of COVID-19.


Viruses ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1651
Author(s):  
Janusz T. Pawęska ◽  
Petrus Jansen van Vuren ◽  
Veerle Msimang ◽  
Modu Moustapha Lô ◽  
Yaya Thiongane ◽  
...  

Diagnostic performance of an indirect enzyme-linked immunosorbent assay (I-ELISA) based on a recombinant nucleocapsid protein (rNP) of the Rift Valley fever virus (RVFV) was validated for the detection of the IgG antibody in sheep (n = 3367), goat (n = 2632), and cattle (n = 3819) sera. Validation data sets were dichotomized according to the results of a virus neutralization test in sera obtained from RVF-endemic (Burkina Faso, Democratic Republic of Congo, Mozambique, Senegal, Uganda, and Yemen) and RVF-free countries (France, Poland, and the USA). Cut-off values were defined using the two-graph receiver operating characteristic analysis. Estimates of the diagnostic specificity of the RVFV rNP I-ELISA in animals from RVF-endemic countries ranged from 98.6% (cattle) to 99.5% (sheep) while in those originating from RVF-free countries, they ranged from 97.7% (sheep) to 98.1% (goats). Estimates of the diagnostic sensitivity in ruminants from RVF-endemic countries ranged from 90.7% (cattle) to 100% (goats). The results of this large-scale international validation study demonstrate the high diagnostic accuracy of the RVFV rNP I-ELISA. Standard incubation and inactivation procedures evaluated did not have an adverse effect on the detectable levels of the anti-RVFV IgG in ruminant sera and thus, together with recombinant antigen-based I-ELISA, provide a simple, safe, and robust diagnostic platform that can be automated and carried out outside expensive bio-containment facilities. These advantages are particularly important for less-resourced countries where there is a need to accelerate and improve RVF surveillance and research on epidemiology as well as to advance disease control measures.


Virology ◽  
2021 ◽  
Vol 557 ◽  
pp. 15-22
Author(s):  
Teodora Djukic ◽  
Maja Mladenovic ◽  
Dragana Stanic-Vucinic ◽  
Jelena Radosavljevic ◽  
Katarina Smiljanic ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jyotsna Shah ◽  
Song Liu ◽  
Hari-Hara Potula ◽  
Prerna Bhargava ◽  
Iris Cruz ◽  
...  

Abstract Background Rapid and simple serological assays for characterizing antibody responses are important in the current COVID-19 pandemic caused by SARS-CoV-2. Multiplex immunoblot (IB) assays termed COVID-19 IB assays were developed for detecting IgG and IgM antibodies to SARS-CoV-2 virus proteins in COVID-19 patients. Methods Recombinant nucleocapsid protein and the S1, S2 and receptor binding domain (RBD) of the spike protein of SARS-CoV-2 were used as target antigens in the COVID-19 IBs. Specificity of the IB assay was established with 231 sera from persons with allergy, unrelated viral infections, autoimmune conditions and suspected tick-borne diseases, and 32 goat antisera to human influenza proteins. IgG and IgM COVID-19 IBs assays were performed on 84 sera obtained at different times after a positive RT-qPCR test from 37 COVID-19 patients with mild symptoms. Results Criteria for determining overall IgG and IgM antibody positivity using the four SARS-CoV-2 proteins were developed by optimizing specificity and sensitivity in the COVID-19 IgG and IgM IB assays. The estimated sensitivities and specificities of the COVID-19 IgG and IgM IBs for IgG and IgM antibodies individually or for either IgG or IgM antibodies meet the US recommendations for laboratory serological diagnostic tests. The proportion of IgM-positive sera from the COVID-19 patients following an RT-qPCR positive test was maximal at 83% before 10 days and decreased to 0% after 100 days, while the proportions of IgG-positive sera tended to plateau between days 11 and 65 at 78–100% and fall to 44% after 100 days. Detection of either IgG or IgM antibodies was better than IgG or IgM alone for assessing seroconversion in COVID-19. Both IgG and IgM antibodies detected RBD less frequently than S1, S2 and N proteins. Conclusions The multiplex COVID-19 IB assays offer many advantages for simultaneously evaluating antibody responses to different SARS-CoV-2 proteins in COVID-19 patients.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sultan Gülce-İz ◽  
Nazif Elaldı ◽  
Hüseyin Can ◽  
Esra Atalay Şahar ◽  
Muhammet Karakavuk ◽  
...  

AbstractCrimean-Congo hemorrhagic fever (CCHF) is a tick-borne viral infection caused by Crimean-Congo hemorrhagic fever virus (CCHFV). Serological screening of CCHF is important and current ELISA use antigens prepared from virus which is expensive due to requirement of high bio-containment facilities. In this study, we aimed to develop a new recombinant ELISA. For this purpose, CCHFV genome were expressed as 13 proteins in E. coli and among them abundantly purified recombinant Nucleocapsid protein (rNP) and Mucin-like variable domain (rMLD) were used as antigen in ELISA (Rec-ELISA). Rec-ELISA using rNP, rMLD and a combination of both (rNP/rMLD) were probed with acute (n = 64; collected between days 1 and 7 after onset of symptoms), convalescent (n = 35; collected 8 days after onset of symptoms), consecutive sera (n = 25) of confirmed CCHF cases and control sera (n = 43). The sensitivity and specificity of Rec-ELISA using rNP/rMLD were 73% and 98% in acute cases and 97% and 98% in convalescent cases. The median interquartile absorbance value to discriminate the acute and convalescent phases of CCHF was significantly higher with ELISA using rNP/rMLD (P < 0.0001) compared to rNP (P > 0.05) and rMLD (P = 0.001). These results indicate that the Rec-ELISA using rNP/rMLD may be very useful to diagnose convalescent CCHF cases especially in field studies.


2019 ◽  
Vol 54 (2) ◽  
pp. 337-346
Author(s):  
D.Yu. Morozova ◽  
◽  
A.R. Imatdinov ◽  
S.P. Zhivoderov ◽  
I.A. Titov ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document