Journal of Neutron Research
Latest Publications


TOTAL DOCUMENTS

630
(FIVE YEARS 98)

H-INDEX

23
(FIVE YEARS 2)

Published By Ios Press

1477-2655, 1023-8166

2021 ◽  
pp. 1-10
Author(s):  
Sjoerd Roorda ◽  
Pat Clancy ◽  
Jonathan Bellemare ◽  
Simon Laliberté-Riverin

With the aim of exploring neutron techniques for the non-destructive detection of hydrogen in embrittled steel, three sets of steel samples were studied with neutron scattering: Ni coated, Cd coated, and Cr coated. Each set contained a non-embrittled or low-hydrogen concentration reference and one or two embrittled and high-hydrogen concentration samples. It is observed that the incoherent scattering, when normalized by the intensity of the Bragg peak, is significantly higher for high-hydrogen concentration or embrittled samples than in the reference. Although the difference is small, this represents a non-destructive technique of detecting hydrogen embrittlement. Neutron radiography, and inelastic or small-angle scattering could not distinguish between embrittled and reference samples.


2021 ◽  
pp. 1-18
Author(s):  
Masatoshi Arai ◽  
Ken H. Andersen ◽  
Dimitri N. Argyriou ◽  
Werner Schweika ◽  
Luca Zanini ◽  
...  

The general performance of diffractometers at the first long pulse spallation source ESS, is compared with their counterparts at J-PARC, a short pulse spallation source. The difference in the inherent pulse structure of these neutron sources presents opportunities for new concepts for instrumentation, where performance does not scale simply with source power. The article describes advantages and disadvantages of those diffractometers, adapting to the very different source characteristics. We find that the two sources offer comparable performance in flux and resolution when operating in high-resolution mode. ESS offers significant advantages in tunability and flexibility, notably in the ability to relax resolution in order to increase flux for a given experiment. The slow repetition rate of ESS favors long instruments. On the other hand, J-PARC instruments perform very well in spite of the lower source power and allow better access to epithermal neutrons, of particular interest for PDF analysis of diffraction data.


2021 ◽  
pp. 1-10
Author(s):  
Reiner Zorn

In quasieleastic neutron scattering spectrometers one usually faces a trade-off between energy resolution and counting statistics. If the resolution is improved the intensity at the detectors reduces and vice versa. It is not immediately clear how to weigh both factors against each other. In this paper it is proposed to use the maximum time obtainable by Fourier transform of the spectra as the quantity to be optimised. It is shown that this leads to a well-defined criterion for the choice of the resolution.


2021 ◽  
pp. 1-15
Author(s):  
Chang-Hee Lee ◽  
Myungkook Moon ◽  
Dong Won Lee ◽  
Han Sung Kim ◽  
Hyeok-Jung Kwon ◽  
...  

This report reviews the overall status of the development and planning activities of compact accelerator-based neutron sources in Korea. For the last decade, the demand for the technology development and application of CANS has significantly increased, and becomes widely accepted by the science, engineering and industry sectors. Since the first technical workshop focused on CANS under the support of the Korea Nuclear Society in fall 2016, there have been numerous efforts to launch projects by several groups. Although unsuccessful, two CANS projects were newly launched in 2020. One is the 30-MeV cyclotron-based neutron source for industrial neutron imaging at the Korea Atomic Energy Research Institute (KAERI), and the other is the BNCT technology development at the Korea Institute of Radiological & Medical Sciences. A project proposal for an expansion of the proton LINAC facility at KAERI to 200 MeV for semiconductor irradiation testing through the produced neutron field is now almost complete and will be submitted to the government funding agency for review. The CANS project for BNCT based on the proton LINAC developed by the Dawonsys consortium is briefly described. The new neutron source based on electron LINAC is prepared by the Pohang Light Source laboratory, and the initial consideration and application targets are also described. A new strategic plan for national R&D on radiation technology and the enforcement of its infrastructure is still under way, and a more systematic approach to the development and application of neutron sources will be implemented through the strategic planning.


2021 ◽  
pp. 1-19
Author(s):  
Robert Laxdal ◽  
Dalini D. Maharaj ◽  
Mina Abbaslou ◽  
Zin Tun ◽  
Daniel Banks ◽  
...  

Canada’s access to neutron beams for neutron scattering was significantly curtailed in 2018 with the closure of the National Research Universal (NRU) reactor in Chalk River, Ontario, Canada. New sources are needed for the long-term; otherwise, access will only become harder as the global supply shrinks. Compact Accelerator-based Neutron Sources (CANS) offer the possibility of an intense source of neutrons with a capital cost significantly lower than spallation sources. In this paper, we propose a CANS for Canada. The proposal is staged with the first stage offering a medium neutron flux, linear accelerator-based approach for neutron scattering that is also coupled with a boron neutron capture therapy (BNCT) station and a positron emission tomography (PET) isotope production station. The first stage will serve as a prototype for a second stage: a higher brightness, higher cost facility that could be viewed as a national centre for neutron applications.


2021 ◽  
pp. 1-7
Author(s):  
Yoshie Otake

RIKEN Accelerator-driven compact neutron source, RANS, has been operational since 2013. There are two major goals of RANS research and development. One is to establish a new compact low energy neutron non-destructive evaluation system on-site of floor-standing type for industrial use. Another goal is to invent a novel transportable compact neutron system for the preventive maintenance of large scale construction such as a bridge. For the realization of the preventive maintenance usage with neutron methods for non-destructive test of large scale structures on-site, “Standardization”, such as inclusion in manuals and inspection procedures, is essential. Technology research association for the infrastructure preventive maintenance standardization is established. RANS and RANS-II are in operation, and RANS-III, and RANS-μ, neutron salt-meter, are under development.


2021 ◽  
pp. 1-11
Author(s):  
José Rolando Granada ◽  
José Ignacio Márquez Damián ◽  
Javier Dawidowski ◽  
José Ignacio Robledo ◽  
Christian Helman ◽  
...  

The newest neutron scattering applications are highly intensity-limited techniques that demand reducing the neutron losses between source and detectors. In addition, the nuclear industry demands more accurate data and procedures for the design and optimization of advanced fission reactors, especially for the treatment of fuel and moderator materials. To meet these demands, it is necessary to improve the existing calculation tools, through the generation of better models that describe the interaction of neutrons with the systems of interest. The Neutron Physics Department at Centro Atomico Bariloche (CNEA, Argentina) has been developing over the time new models for the interaction of slow neutrons with materials, to produce scattering kernels and cross section data in the thermal and cold neutron energy region. Besides the studies carried out on neutron moderators, we have recently begun looking at materials that could serve as efficient neutron reflectors over those energy ranges. In this work we present the results of transmission and scattering experiments on diamond nanopowder and magnesium hydride, carried out simultaneously at the VESUVIO spectrometer (ISIS, UK), and compare them with newly generated cross-section libraries.


2021 ◽  
pp. 1-5
Author(s):  
Huarui Wu ◽  
Weihang Hong ◽  
Yao Zhang ◽  
Pulin Bai ◽  
Wenbo Mo ◽  
...  

Developing small-angle neutron scattering techniques at compact accelerator-driven neutron sources (CANS) is of great importance for expanding the user community and advancing CANS capability. At the Compact Pulsed Hadron Source (CPHS) at Tsinghua University, neutron-focusing mirrors are under intensive research to address the challenge. A grazing-incidence focusing SANS (gif-SANS) project is initialized. It employs a nested supermirror assembly with a large collecting area to achieve ⩾ 10 5 n/s neutron intensity at Q min ⩽ 0.007 Å − 1 . It will equip two detectors, one being a 3He detector for normal Q-range measurements, and the other being a high-resolution detector for extending the Q min down to 10 − 3 Å − 1 . In this work, we present the conceptual design of the gif-SANS at CPHS. Such a scheme is conducive to enable high-performance SANS measurements at CANS.


2021 ◽  
pp. 1-8
Author(s):  
V.V. Kruglov ◽  
A.M. Balagurov ◽  
M.O. Belova ◽  
I.A. Bobrikov ◽  
A.A. Bogdzel ◽  
...  

The high-resolution Fourier diffractometer (HRFD) operates at the IBR-2 pulsed reactor, on which the correlation method of data registering has been implemented using a fast Fourier chopper and specialized electronics. A wide-aperture ring back-scattering detector for HRFD has been developed. The detector consists of six Z n S ( A g ) / 6 L i F-scintillation rings, each one of which is divided into 12 sections. Main parameters of this detector: covered solid angle 2 θ = ( 133 − 175 ) ∘ ; Ω d ≈ 2.0 sr; average absorption efficiency 85 %, geometric contribution to resolution Δ d / d < 0.0005. The concept of a detector and its data acquisition system are presented.


2021 ◽  
pp. 1-14
Author(s):  
Marius Rimmler ◽  
Olaf Felden ◽  
Ulrich Rücker ◽  
Helmut Soltner ◽  
Paul Zakalek ◽  
...  

The High-Brilliance Neutron Source project (HBS) aims at developing a medium-flux accelerator-driven neutron source based on a 70 MeV, 100 mA proton accelerator. The concept optimizes the facility such that it provides high-brilliance neutron beams for instruments operating at different time structures. This can be realized by generating an interlaced proton pulse structure, which is unraveled and sent to three different target stations by a multiplexer system. In the following we present the developments of a multiplexer system at the JULIC accelerator at Forschungszentrum Jülich GmbH (FZJ), which serves as test facility for HBS. The main components of the JULIC multiplexer system are designed to be scalable to the HBS parameters.


Sign in / Sign up