Time-resolved in-situ pH measurement in differently treated, saturated and unsaturated soils

2015 ◽  
Vol 178 (3) ◽  
pp. 425-432 ◽  
Author(s):  
Sören Thiele-Bruhn ◽  
Stefan Wessel-Bothe ◽  
Marc-Oliver Aust
Author(s):  
J. Allègre ◽  
P. Lefebvre ◽  
J. Camassel ◽  
B. Beaumont ◽  
Pierre Gibart

Time-resolved photoluminescence spectra have been recorded on three GaN epitaxial layers of thickness 2.5 μm, 7 μm and 16 μm, at various temperatures ranging from 8K to 300K. The layers were deposited by MOVPE on (0001) sapphire substrates with standard AlN buffer layers. To achieve good homogeneities, the growth was in-situ monitored by laser reflectometry. All GaN layers showed sharp excitonic peaks in cw PL and three excitonic contributions were seen by reflectivity. The recombination dynamics of excitons depends strongly upon the layer thickness. For the thinnest layer, exponential decays with τ ~ 35 ps have been measured for both XA and XB free excitons. For the thickest layer, the decay becomes biexponential with τ1 ~ 80 ps and τ2 ~ 250 ps. These values are preserved up to room temperature. By solving coupled rate equations in a four-level model, this evolution is interpreted in terms of the reduction of density of both shallow impurities and deep traps, versus layer thickness, roughly following a L−1 law.


2020 ◽  
Author(s):  
Luzia S. Germann ◽  
Sebastian T. Emmerling ◽  
Manuel Wilke ◽  
Robert E. Dinnebier ◽  
Mariarosa Moneghini ◽  
...  

Time-resolved mechanochemical cocrystallisation studies have so-far focused solely on neat and liquid-assisted grinding. Here, we report the monitoring of polymer-assisted grinding reactions using <i>in situ</i> X-ray powder diffraction, revealing that reaction rate is almost double compared to neat grinding and independent of the molecular weight and amount of used polymer additives.<br>


2019 ◽  
Author(s):  
Hao Wu ◽  
Jeffrey Ting ◽  
Siqi Meng ◽  
Matthew Tirrell

We have directly observed the <i>in situ</i> self-assembly kinetics of polyelectrolyte complex (PEC) micelles by synchrotron time-resolved small-angle X-ray scattering, equipped with a stopped-flow device that provides millisecond temporal resolution. This work has elucidated one general kinetic pathway for the process of PEC micelle formation, which provides useful physical insights for increasing our fundamental understanding of complexation and self-assembly dynamics driven by electrostatic interactions that occur on ultrafast timescales.


2021 ◽  
Vol 11 (6) ◽  
pp. 2021-2025
Author(s):  
Liujin Wei ◽  
Guan Huang ◽  
Yajun Zhang

The combination of time-resolved transient photoluminescence with in-situ Fourier transform infrared spectroscopy has been conducted to investigate the intrinsic phase structure-dependent activity of Bi2O3 catalyst for CO2 reduction.


Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3682
Author(s):  
Katarína Vizárová ◽  
Izabela Vajová ◽  
Naďa Krivoňáková ◽  
Radko Tiňo ◽  
Zdenko Takáč ◽  
...  

The surface pH is a critical factor in the quality and longevity of materials and products. Traditional fast colorimetric pH detection-based tests such as water quality control or pregnancy tests, when results are determined by the naked eye, cannot provide quantitative values. Using standard pH papers, paper-printed comparison charts, or colorimetric microfluidic paper-based analytical devices is not suitable for such technological applications and quality management systems (QMSs) where the particular tested material should contain a suitable indicator in situ, in its structure, either before or after the process, the technology or the apparatus that are being tested. This paper describes a method based on the combination of impregnation of a tested material with a pH indicator in situ, its exposure to a process of technology whose impact on pH value is to be tested, colorimetric pH measurement, and approximation of pH value using derived pH characteristic parameters (pH-CPs) based on CIE orthogonal and cylindrical color variables. The hypotheses were experimentally verified using the methyl red pH indicator, impregnating the acid lignin-containing paper, and preparing a calibration sample set with pH in the range 4 to 12 using controlled alkalization. Based on the performed measurements and statistical evaluation, it can be concluded that the best pH-CPs with the highest regression parameters for pH are √∆E, ln (a),√∆H (ab), a/L, h/b and ln (b/a). The experimental results show that the presented method allows a good estimation of pH detection of the material surfaces.


Sign in / Sign up

Export Citation Format

Share Document