The Mechanical Properties of PMMA Bone Cement

Author(s):  
Clive Lee
2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Ching-Lung Tai ◽  
Po-Liang Lai ◽  
Wei-De Lin ◽  
Tsung-Tin Tsai ◽  
Yen-Chen Lee ◽  
...  

Polymethylmethacrylate (PMMA) bone cement is a popular bone void filler for vertebroplasty. However, the use of PMMA has some drawbacks, including the material’s excessive stiffness, exothermic polymerization, and short handling time. This study aimed to create an ideal modified bone cement to solve the above-mentioned problems. Modified bone cements were prepared by combining PMMA with three different volume fractions of castor oil (5%, 10%, and 15%). The peak polymerization temperatures, times to achieve the peak polymerization temperature, porosities, densities, modulus and maximum compression strengths of standard (without castor oil), and modified cements were investigated following storage at ambient temperature (22°C) or under precooling conditions (3°C). Six specimens were tested in each group of the aforementioned parameters. Increasing castor oil content and precooling treatment effectively decreased the peak polymerization temperatures and increased the duration to achieve the peak polymerization temperature (P<0.05). Furthermore, the mechanical properties of the material, including density, modulus, and maximum compression strength, decreased with increasing castor oil content. However, preparation temperature (room temperature versus precooling) had no significant effect (P>0.05) on these mechanical properties. In conclusion, the addition of castor oil to PMMA followed by precooling created an ideal modified bone cement with a low modulus, low polymerization temperature, and long handling time, enhancing its applicability and safety for vertebroplasty.


Author(s):  
Ehsan Basafa ◽  
Ryan J. Murphy ◽  
Michael D. Kutzer ◽  
Yoshito Otake ◽  
Mehran Armand

We report the results of planning and experimental validation of femoroplasty — augmentation of mechanical properties of the bone using polymethylmethacrylate (PMMA) bone cement injection — on osteoporotic femurs. For six pairs of osteoporotic femurs, finite element (FE) models were created using computed tomography (CT) scan data and an evolutionary method was used to optimize the cement pattern in one of the models from each pair. Using a particle method and the CT data, cement diffusion was modeled for several hypothetical augmentations and the one most closely matching the optimized pattern was chosen as the best plan. We used intra-operative navigation and a custom-designed injection device to deliver the cement into the bones precisely according to the plan. All femurs were then tested mechanically in a configuration simulating a fall to the side. Augmentation with this technique resulted in an increase in the yield load (28%) and yield energy (142%) compared to the control specimens, while only 9.8ml of cement was injected on average. Results support our hypothesis that significant improvements in the mechanical properties of osteoporotic femurs can be achieved by using minimal, and hence safe, amounts of PMMA bone cement.


2021 ◽  
Vol 9 (8) ◽  
pp. 3112-3126
Author(s):  
M. Wekwejt ◽  
S. Chen ◽  
B. Kaczmarek-Szczepańska ◽  
M. Nadolska ◽  
K. Łukowicz ◽  
...  

Nanosilver-loaded PMMA bone cement doped with bioactive glasses is a novel cement developed as a replacement for conventional cements.


2006 ◽  
Vol 309-311 ◽  
pp. 797-800 ◽  
Author(s):  
Masami Hashimoto ◽  
Hiroaki Takadama ◽  
Mineo Mizuno ◽  
Tadashi Kokubo ◽  
Koji Goto ◽  
...  

Bioactive bone cement with mechanical properties higher than that of commercial polymethylmethacrylate (PMMA) bone cement are strongly desired to be developed. In the present study, PMMA-based cement incorporated with nano-sized rutile particles was prepared. The PMMA-based cement (rutile content was 50 wt%) shows the compressive strength (136 MPa) higher than that of commercial PMMA bone cement (88 MPa). The hardened cement formed apatite on the surface in a simulated body fluid within 3 days. Therefore, this PMMA-based cement incorporated with rutile particles might be useful as cement for fixation of prostheses as well as self-setting bone substitutes, because of its high apatite forming ability and mechanical strength.


2018 ◽  
Vol 766 ◽  
pp. 117-121
Author(s):  
Phanrawee Sriprapha ◽  
Chaiy Rungsiyakull ◽  
Kamonpan Pengpat ◽  
Tawee Tunkasiri ◽  
Sukum Eitssayeam

In this research, mechanical properties of bone cement containing micro-and nanohydroxyapatite (HAp) particles were studied. The bone cement was prepared from mixing between polymethyl methacrylate (PMMA) and methyl methacrylate (MMA). Hydroxyapatite powder was prepared from bovine bone. The bone was heated in hot water at 200 oc for the elimination of tissue, after which the bone was dried and calcined at 800 oc for 3 hrs. The calcined bone than was crushed into powder and ball-milled for 24 hrs. The micro-HAp particle was then obtained. The micro particles were then further milled employing the Vibro-milling machine for 2 hrs. The micro-and nanoHAp sizes are about 0.5 μm and 140 nm, respectively. The both size powders were treated with γ-methacrylic-propyl-tri-methoxy silane. The acetic acid was added to control the pH of the solution, until it reached 2.9 before they were mixed into the bone cement with equally wt%. The mixture was casted using the 304 stainless steel mold in order to obtain a cylindrical shape. The low vacuum scanning electron microscope (LV-SEM) and x-ray diffractometer (XRD) were employed to characterize the samples. The porosity of PMMA could be reduced by HAp particle additives. From compressive strength test, it was found that the mixture of bone cement and nanoHAp particle has shown higher compressive strength than pure PMMA bone cement that affected by porosity reduction and force distribution by HAp particles.


Author(s):  
P K Humphreys ◽  
J F Orr ◽  
A S Bahrani

A titanium alloy hip prosthesis was inserted in a Tufnol tube representing the upper part of the femur. The prosthesis was cemented in the model femur using PMMA bone cement. Five thermocouples were embedded in the bone cement and the assembly was subjected to cyclic loading with a range of 0.3–4.5 kN at a frequency of 6 Hz. Temperature measurements over a 48 hour period indicated that the temperature rise in the bone cement was less than 4°C. It is concluded that such tests can be carried out at 6 Hz without significantly affecting the mechanical properties of PMMA bone cement.


2006 ◽  
Vol 17 (12) ◽  
pp. 1433-1448 ◽  
Author(s):  
R. P. S. Chaplin ◽  
A. J. C. Lee ◽  
R. M. Hooper ◽  
M. Clarke

Polymers ◽  
2021 ◽  
Vol 13 (12) ◽  
pp. 2027
Author(s):  
Jaime Orellana ◽  
Ynés Yohana Pastor ◽  
Fernando Calle ◽  
José Ygnacio Pastor

Bone cement, frequently based on poly (methyl methacrylate), is commonly used in different arthroplasty surgical procedures and its use is essential for prosthesis fixation. However, its manufacturing process reaches high temperatures (up to 120 °C), producing necrosis in the patients' surrounding tissues. To help avoid this problem, the addition of graphene could delay the polymerisation of the methyl methacrylate as it could, simultaneously, favour the optimisation of the composite material's properties. In this work, we address the effect of different percentages of highly reduced graphene oxide with different wt.% (0.10, 0.50, and 1.00) and surface densities (150, 300, 500, and 750 m2/g) on the physical, mechanical, and thermal properties of commercial poly (methyl methacrylate)-based bone cement and its processing. It was noted that a lower sintering temperature was achieved with this addition, making it less harmful to use in surgery and reducing its adverse effects. In contrast, the variation of the density of the materials did not introduce significant changes, which indicates that the addition of highly reduced graphene oxide would not significantly increase bone porosity. Lastly, the mechanical properties (strength, elastic modulus, and fracture toughness) were reduced by almost 20%. Nevertheless, their typical values are high enough that these new materials could still fulfil their structural function. In conclusion, this paper presents a way to control the sintering temperature, without significant degradation of the mechanical performance, by adding highly reduced graphene oxide so that local necrosis of bone cement based on poly (methyl methacrylate) used in surgery is avoided.


2020 ◽  
Author(s):  
Changtian Gong ◽  
Shuo Fang ◽  
Kezhou Xia ◽  
Jingteng Chen ◽  
Liangyu Guo ◽  
...  

Abstract Incorporating bioactive substances into synthetic bioceramic scaffolds is challenging. In this work, oxygen-carboxymethyl chitosan (O-CMC), a natural biopolymer that is nontoxic, biodegradable and biocompatible, was introduced into magnesium potassium phosphate cement (K-struvite) to enhance its mechanical properties and cytocompatibility. This study aimed to develop O-CMC/magnesium potassium phosphate composite bone cement (OMPC), thereby combining the optimum bioactivity of O-CMC with the extraordinary self-setting properties and mechanical intensity of the K-struvite. Our results indicated that O-CMC incorporation increased the compressive strength and setting time of K-struvite and decreased its porosity and pH value. Furthermore, OMPC scaffolds remarkably improved the proliferation, adhesion and osteogenesis related differentiation of MC3T3-E1 cells. Therefore, O-CMC introduced suitable physicochemical properties to K-struvite and enhanced its cytocompatibility for use in bone regeneration.


Sign in / Sign up

Export Citation Format

Share Document