Proton Density Variation in Ionosphere Before Strong Earthquake Using GOES-15 Data

Author(s):  
Pranab Hazra ◽  
Tamanna Islam
1950 ◽  
Vol 79 (6) ◽  
pp. 1019-1020 ◽  
Author(s):  
Helmut Steinwedel ◽  
Michael Danos

Author(s):  
Philip D. Lunger ◽  
H. Fred Clark

In the course of fine structure studies of spontaneous “C-type” particle production in a viper (Vipera russelli) spleen cell line, designated VSW, virus particles were frequently observed within mitochondria. The latter were usually enlarged or swollen, compared to virus-free mitochondria, and displayed a considerable degree of cristae disorganization.Intramitochondrial viruses measure 90 to 100 mμ in diameter, and consist of a nucleoid or core region of varying density and measuring approximately 45 mμ in diameter. Nucleoid density variation is presumed to reflect varying degrees of condensation, and hence maturation stages. The core region is surrounded by a less-dense outer zone presumably representing viral capsid.Particles are usually situated in peripheral regions of the mitochondrion. In most instances they appear to be lodged between loosely apposed inner and outer mitochondrial membranes.


Reproduction ◽  
2000 ◽  
pp. 311-323 ◽  
Author(s):  
JL Hilton ◽  
GE Sarty ◽  
GP Adams ◽  
RA Pierson

The magnetic resonance images and maps of bovine ovaries acquired at defined phases of follicular development and regression were studied to determine whether magnetic resonance image attributes of the follicular antrum reflect the physiological status of dominant and subordinate ovarian follicles. Ovariectomies were performed at day 3 of wave one, day 6 of wave one, day 1 of wave two and at >/= day 17 after ovulation. The timings of ovariectomies were selected to acquire growing, early static, late static and regressing follicles of the first wave and preovulatory follicles of the ovulatory wave. Pre-selection and subordinate follicles were also available for analysis. Serum samples were taken on the day of ovariectomy and follicular fluid samples were taken after imaging. Numerical pixel value and pixel heterogeneity in a spot representing approximately 95% of the follicular antrum were quantified in T(1)- and T(2)-weighted images. T(1) and T(2) relaxation rates (T(1) and T(2)), proton density, apparent diffusion coefficients and their heterogeneities were determined from the computed magnetic resonance maps. The antra of early atretic dominant follicles showed higher T(2)-weighted mean pixel value (P < 0.008) and heterogeneity (P < 0. 01) and lower T(2) heterogeneity (P < 0.008) than growing follicles. Subordinate follicles in the presence of a preovulatory dominant follicle had higher T(1), T(1) heterogeneity, proton density, proton density heterogeneity, and lower mean pixel value in T(1)-weighted images than subordinate follicles of the anovulatory wave (P < 0.04). T(1) relaxation rate heterogeneity and proton density heterogeneity were positively correlated with follicular fluid oestradiol concentration (r = 0.4 and 0.3; P < 0.04). T(2) relaxation rate heterogeneity was positively correlated with follicular fluid progesterone concentration (r = 0.4; P < 0.008). Quantitative differences in magnetic resonance image attributes of the antrum observed among phases of follicular development and regression coincided with changes in the ability of the dominant follicle to produce steroid hormones and ovulate, and thus were indicative of physiological status and follicular health.


2015 ◽  
Vol 7 (2) ◽  
pp. 1428-1439
Author(s):  
Khurshed Alam ◽  
Md. Sayeedur Rahman ◽  
Md. Mostafizur Rahman ◽  
S. M. Azaharul Islam

A powerful non-destructive testing (NDT) technique is adopted to study the internal defects and elemental distribution/homogeneity and porosity of aerated brick and EPS aggregate poly brick samples. In the present study the internal defects like homogeneity, porosity, elemental distribution, EPS aggregate and aerator distributor in the test samples have been observed by the measurement of gray value/optical density of the neutron radiographic images of these samples. From this measurement it is found that the neutron intensity/optical density variation with the pixel distance of the AOI of the NR images in both expanded polystyrene (EPS) aggregate poly brick and aerated brick samples comply almost same in nature with respect to the whole AOI but individually each AOI shows different nature from one AOI to another and it confirms that the elemental distribution within a AOI is almost homogeneous. Finally it was concluded that homogeneity, elemental distribution in the EPS aggregate poly brick sample is better than that of the aerated brick sample. 


2013 ◽  
Vol 12 (1) ◽  
pp. 1-10 ◽  
Author(s):  
Mikhail Dobrovolsky ◽  
Alexei Gvishiani ◽  
Sergey Agayan ◽  
Boris Dzeboev
Keyword(s):  

2011 ◽  
Vol 8 (1) ◽  
pp. 201-210
Author(s):  
R.M. Bogdanov

The problem of determining the repair sections of the main oil pipeline is solved, basing on the classification of images using distance functions and the clustering principle, The criteria characterizing the cluster are determined by certain given values, based on a comparison with which the defect is assigned to a given cluster, procedures for the redistribution of defects in cluster zones are provided, and the cluster zones parameters are being changed. Calculations are demonstrating the range of defect density variation depending on pipeline sections and the universal capabilities of linear objects configuration with arbitrary density, provided by cluster analysis.


Author(s):  
Qinglin Meng ◽  
Mengqi Liu ◽  
Weiwei Deng ◽  
Ke Chen ◽  
Botao Wang ◽  
...  

Background: Calcium-suppressed (CaSupp) technique involving spectral-based images has been used to observe bone marrow edema by removing calcium components from the image. Objective: This study aimed to evaluate the knee articular cartilage using the CaSupp technique in dual-layer detector computed tomography (DLCT). Methods: Twenty-eight healthy participants and two patients with osteoarthritis were enrolled, who underwent DLCT and magnetic resonance imaging (MRI) examination. CaSupp images were reconstructed from spectral-based images using a calcium suppression algorithm and were overlaid conventional CT images for visual evaluation. The morphology of the knee cartilage was evaluated, and the thickness of the articular cartilage was measured on sagittal proton density– weighted and CaSupp images in the patellofemoral compartment. Results: No abnormal signal or density, cartilage defect, and subjacent bone ulceration were observed in the lateral and medial femorotibial compartments and the patellofemoral compartment on MRI images and CaSupp images for the 48 normal knee joints. CaSupp images could clearly identify cartilage thinning, defect, subjacent bone marrow edema, and edema of the infrapatellar fat pad in the same way as MRI images in the three knee joints with osteoarthritis. A significant difference was found in the mean thickness of the patellar cartilage between MRI images and CaSupp images, while the femoral cartilage presented no significant difference in thickness between MRI images and CaSupp images over all 48 knee joints. Conclusion: The present study demonstrated that CaSupp images could effectively be used to perform the visual and quantitative assessment of knee cartilage.


Sign in / Sign up

Export Citation Format

Share Document