Preparation of silver nanoparticles with ionic liquid-modified carbon dots: from mechanism to the application in H2O2 sensing

2020 ◽  
Vol 55 (36) ◽  
pp. 16928-16939
Author(s):  
Quanxing Mao ◽  
Xiaolei Kong ◽  
E Shuang ◽  
Jianhua Wang ◽  
Xuwei Chen
2021 ◽  
Vol 330 ◽  
pp. 115548
Author(s):  
Paulo R. Souza ◽  
Bruno H. Vilsinski ◽  
Ariel C. de Oliveira ◽  
Sharise B.R. Berton ◽  
Cátia S. Nunes ◽  
...  

Molecules ◽  
2020 ◽  
Vol 25 (24) ◽  
pp. 5798
Author(s):  
Amir Reza Sadrolhosseini ◽  
Ganesan Krishnan ◽  
Suhaidi Shafie ◽  
Suraya Abdul Rashid ◽  
Sulaiman Wadi Harun

This study used the carbon dots solution for the laser ablation technique to fabricate silver nanoparticles. The ablation time range was from 5 min to 20 min. Analytical methods, including Fourier transform infrared spectroscopy (FTIR), UV-visible spectroscopy, transmission electron microscopy, and Raman spectroscopy were used to categorize the prepared samples. The UV-visible and z-scan techniques provided optical parameters such as linear and nonlinear refractive indices in the range of 1.56759 to 1.81288 and 7.3769 × 10−10 cm2 W−1 to 9.5269 × 10−10 cm2 W−1 and the nonlinear susceptibility was measured in the range of 5.46 × 10−8 to 6.97 × 10−8 esu. The thermal effusivity of prepared samples, which were measured using the photoacoustic technique, were in the range of 0.0941 W s1/2 cm−2 K−1 to 0.8491 W s1/2 cm−2 K−1. The interaction of the prepared sample with fluoride was investigated using a Raman spectrometer. Consequently, the intensity of the Raman signal decreased with the increasing concentration of fluoride, and the detection limit is about 0.1 ppm.


2017 ◽  
Vol 46 (36) ◽  
pp. 12306-12312 ◽  
Author(s):  
Yunxiao Zhang ◽  
Tao Cai ◽  
Wangji Shang ◽  
Dan Liu ◽  
Qiang Guo ◽  
...  

An inorganic-organic carbon dots consisting of an ionic liquid moiety inserted in the carbon skeleton has been synthesized and verified to be a high-performance anti-wear and friction-reducing lubricant additives in poly(ethylene glycol)(PEG).


2021 ◽  
pp. 1-8
Author(s):  
Susan Sadeghi ◽  
Mohadeseh Hosseinpour-Zaryabi

A dispersive liquid-phase microextraction method combined with UV–vis spectrophotometry was utilized to highly selective determination of creatinine in human serum and urine samples. To overcome the interferences in complex matrices, creatinine reacted with 1,4-naphthoquinone-2- potassium sulfonate reagent to produce a red coloured product that could be extracted into a small volume of 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM]PF6) ionic liquid solvent. To increase the sensitivity of the assay, gluconic acid capped silver nanoparticles (Ag NPs) were used. On addition of Ag NPs to the red coloured extracted product, the solution turned to blue accompanied with a red shift in wavelength around 620 nm that could be detected by the naked eye. The effective variables on the determination of creatinine such as concentration of the reagent, amount of formic and hydrochloric acids, type and volume of the extractant, and concentration of Ag NPs were investigated. Under the optimal conditions, the calibration plot was bimodal with linear ranges from 0.1 to 1.5 µg mL−1 and 1.5 to 105 µg mL−1 creatinine with a limit of detection 0.1 µg mL−1. The relative standard deviation for five measurements at 35 µg mL−1 concentration level was 3.8%. The newly developed assay was used for the determination of creatinine in human serum and urine specimens with satisfactory results.


Carbon ◽  
2019 ◽  
Vol 154 ◽  
pp. 301-312 ◽  
Author(s):  
Zihao Mou ◽  
Baogang Wang ◽  
Hongsheng Lu ◽  
Shanshan Dai ◽  
Zhiyu Huang

2014 ◽  
Vol 48 (8) ◽  
pp. 790-800 ◽  
Author(s):  
A. Abbaszadegan ◽  
M. Nabavizadeh ◽  
A. Gholami ◽  
Z. S. Aleyasin ◽  
S. Dorostkar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document