scholarly journals Conception and evaluation of a washable multimodal smart textile

Author(s):  
Nils A. Lahmann ◽  
Ursula Müller-Werdan ◽  
Simone Kuntz ◽  
Jürgen Klingehöfer-Noe ◽  
Fabian Jaenicke ◽  
...  

AbstractSmart textiles can support people with specific needs and diseases, such as diabetes or heart disease. Currently there are efforts to combine continuous mobile monitoring with other health-related conditions. On this basis, algorithms could be developed that can be used to detect unusual or critical conditions. A study was to investigate whether a previously developed washable Multi-Modal Smart Textile (MMST), based on inexpensive materials, would provide valid and reliable results with regard to the vital parameters of pulse, temperature and mobility. The measurement of the vital parameters was carried out with the developed prototype MMST as well as with validated devices. All electronics including the rechargeable NiMH has been washed more than 30 times with different methods and it remained fully functional. The intraclass correlation coefficients (ICC) for pulse (temperature) measurement ranged between 0.036 and 0.232 (0.077 and 0.817) depending on the activity of the tested individuals (standing, sitting, lying down, moving). Cohen’s Kappa for the detection of the body position was 0.765. For the parameter of pulse, the results indicated an insufficient derivation for both validity and reliability. Due to flaws in the methodology applied, the validly and reliably for the parameter of temperature could not be determined. Valid and reliable results were obtained for the parameter mobility/change of position. If the MMST (after modification of the prototype) achieves reliable results, there are many advantages for people giving and receiving care on a budget price, even in threatening emergency situations.

2009 ◽  
Vol 9 (3) ◽  
pp. 331-338 ◽  
Author(s):  
Maria Aparecida Conti ◽  
Táki Athanássios Cordás ◽  
Maria do Rosário Dias de Oliveira Latorre

OBJECTIVES: to produce evidence of the validity and reliability of the Body Shape Questionnaire (BSQ) - a tool for measuring an individual's attitude towards his or her body image. METHODS: the study covered 386 young people of both sexes aged between 10 and 18 from a private school and used self-applied questionnaires and anthropometric evaluation. It evaluated the internal consistency, the discriminant validity for differences from the means, according to nutritional status (underweight, eutrophic, overweight and obese), the concurrent validity by way of Spearman's correlation coefficient between the scale and the Body Mass Index (BMI), the waist-hip circumference ratio (WHR) and the waist circumference (WC). Reliability was tested using Wilcoxon's Test, the intraclass correlation coefficient and the Bland-Altman figures. RESULTS: the BSQ displayed good internal consistency (±=0.96) and was capable of discriminating among the total population, boys and girls, according to nutritional status (p<0.001). It correlated with the BMI (r=0.41; p<0.001), WHR (r=-0.10; p=0.043) and WC (r=0.24; p<0.001) and its reliability was confirmed by intraclass correlation (r=0.91; p<0.001) for the total population. The questionnaire was easy to understand and could be completed quickly. CONCLUSIONS: the BSQ presented good results, thereby providing evidence of its validity and reliability. It is therefore recommended for evaluation of body image attitudes among adolescents.


Author(s):  
Steffen Held ◽  
Ludwig Rappelt ◽  
Jan-Philip Deutsch ◽  
Lars Donath

The accurate assessment of the mean concentric barbell velocity (MCV) and its displacement are crucial aspects of resistance training. Therefore, the validity and reliability indicators of an easy-to-use inertial measurement unit (VmaxPro®) were examined. Nineteen trained males (23.1 ± 3.2 years, 1.78 ± 0.08 m, 75.8 ± 9.8 kg; Squat 1-Repetition maximum (1RM): 114.8 ± 24.5 kg) performed squats and hip thrusts (3–5 sets, 30 repetitions total, 75% 1RM) on two separate days. The MCV and displacement were simultaneously measured using VmaxPro® and a linear position transducer (Speed4Lift®). Good to excellent intraclass correlation coefficients (0.91 < ICC < 0.96) with a small systematic bias (p < 0.001; ηp2 < 0.50) for squats (0.01 ± 0.04 m·s−1) and hip thrusts (0.01 ± 0.05 m·s−1) and a low limit of agreement (LoA < 0.12 m·s−1) indicated an acceptable validity. The within- and between-day reliability of the MCV revealed good ICCs (0.55 < ICC < 0.91) and a low LoA (<0.16 m·s−1). Although the displacement revealed a systematic bias during squats (p < 0.001; ηp2 < 0.10; 3.4 ± 3.4 cm), no bias was detectable during hip thrusts (p = 0.784; ηp2 < 0.001; 0.3 ± 3.3 cm). The displacement showed moderate to good ICCs (0.43 to 0.95) but a high LoA (7.8 to 10.7 cm) for the validity and (within- and between-day) reliability of squats and hip thrusts. The VmaxPro® is considered to be a valid and reliable tool for the MCV assessment.


2020 ◽  
pp. 026921552096670
Author(s):  
Huayi Xing ◽  
Nan Liu ◽  
Fin Biering-Sørensen

Objective: To investigate the validity and reliability of a Chinese version of Spinal Cord Independence Measure III (SCIM III) in individuals with spinal cord injury. Design: Study on psychometric properties. Setting: An inpatient rehabilitation facility in China. Subjects: 102 participants with spinal cord injury. Mean (SD) age was 48.8 (15.6) years; tetraplegia/paraplegia ratio was 50/52; median time post injury was 2 months. Intervention: SCIM III was translated into Chinese. Chinese versions of Barthel Index and SCIM III were filled out for each participant by Rater 1. SCIM III was then administered by Rater 2 after 24 hours ( n = 67) and 7 days ( n = 65). Main Measures: Validity, inter-rater/test-retest reliability, and internal consistency of the Chinese version of SCIM III. Results: The total scores between the two raters were similar (mean ± SD: 33.8 ± 25.8 vs 33.8 ± 25.5, P = 0.95). Total agreement between the raters in each item was >80%, with both Pearson and intraclass correlation coefficients >0.97 ( P < 0.01) for each subscale and total score. The Pearson correlation coefficients of the two independent assessments performed by Rater 2 were also >0.97 ( P < 0.01) for each subscale and the total score. Cronbach α was >0.7 for each subscale and the total score for both raters. High consistency was found between Barthel Index and SCIM III total scores (Pearson correlation coefficient = 0.88, P < 0.01). Conclusion: The Chinese version of SCIM III is valid and reliable for the functional assessment of patients with SCI.


Sensors ◽  
2019 ◽  
Vol 19 (2) ◽  
pp. 265 ◽  
Author(s):  
Kristen Renner ◽  
DS Williams ◽  
Robin Queen

The assessment of loading during walking and running has historically been limited to data collection in laboratory settings or with devices that require a computer connection. This study aims to determine if the loadsol®—a single sensor wireless insole—is a valid and reliable method of assessing force. Thirty (17 male and 13 female) recreationally active individuals were recruited for a two visit study where they walked (1.3 m/s) and ran (3.0 and 3.5 m/s) at a 0%, 10% incline, and 10% decline, with the visits approximately one week apart. Ground reaction force data was collected on an instrumented treadmill (1440 Hz) and with the loadsol® (100 Hz). Ten individuals completed the day 1 protocol with a newer 200 Hz loadsol®. Intraclass correlation coefficients (ICC3,k) were used to assess validity and reliability and Bland–Altman plots were generated to better understand loadsol® validity. Across conditions, the peak force ICCs ranged from 0.78 to 0.97, which increased to 0.84–0.99 with the 200 Hz insoles. Similarly, the loading rate ICCs improved from 0.61 to 0.97 to 0.80–0.96 and impulse improved from 0.61 to 0.97 to 0.90–0.97. The 200 Hz insoles may be needed for loading rate and impulse in running. For both walking and running, the loadsol® has excellent between-day reliability (>0.76).


2019 ◽  
Vol 26 (9) ◽  
pp. 1102-1110 ◽  
Author(s):  
Ruth Ann Marrie ◽  
Brenden Dufault ◽  
Tuula Tyry ◽  
Gary R Cutter ◽  
Robert J Fox ◽  
...  

Background: Researchers studying health-related quality of life (HRQOL) in multiple sclerosis (MS) can choose from many instruments, but findings from studies which use different instruments cannot be easily combined. We aimed to develop a crosswalk that associates scores from the RAND-12 to scores on the Health Utilities Index—Mark III (HUI3) in persons with MS. Methods: In 2018, participants in the North American Research Committee on Multiple Sclerosis (NARCOMS) registry completed the RAND-12 and the HUI3 to assess HRQOL. We used item-response theory (IRT) and equipercentile linking approaches to develop a crosswalk between instruments. We compared predicted scores for the HUI3 from each crosswalk to observed scores using Pearson correlations, intraclass correlation coefficients (ICCs), and Bland–Altman plots. Results: Of 11,389 invited participants, 7129 (62.6%) responded. Predicted and observed values of the HUI3 from the IRT-linking method were moderately correlated (Pearson r = 0.76) with good concordance (ICC = 0.72). However, the Bland–Altman plots suggested biased prediction. Predicted and observed values from the equipercentile linking method were also moderately correlated (Pearson r = 0.78, ICC = 0.78). The Bland–Altman plots suggested no bias. Conclusion: We developed a crosswalk between the RAND-12 and the HUI3 in the MS population which will facilitate data harmonization efforts.


2004 ◽  
Vol 29 (5) ◽  
pp. 623-638 ◽  
Author(s):  
Damien Trivel ◽  
Paul Calmels ◽  
Luc Léger ◽  
Thierry Busso ◽  
Xavier Devillard ◽  
...  

The usual fitness tests available to assess maximal oxygen uptake [Formula: see text] a key fitness component, are not particularly useful for epidemiological studies. Questionnaires to assess [Formula: see text] however, are simple, easy to use, and inexpensive. In 1986, Huet developed such a French general questionnaire, which now also has an English version. Its simplicity is interesting as it could be used to survey large populations. The purpose of this study was to assess the validity and reliability of this Huet questionnaire in a sample of healthy French volunteers. A total of 108 subjects were included in this study, 88 males and 20 females. The validity of the questionnaire was checked using correlation coefficients and a Bland-Altman plot between questionnaire estimations and measures of [Formula: see text] obtained with a stress test on a cycle ergometer. An intraclass correlation coefficient (ICC) was also calculated to determine the reliability of the questionnaire. Significant correlation was obtained with the Huet questionnaire and measured [Formula: see text] (r2 = 0.77, p = 0.0001, SEE = 5.97 ml•kg−1•min−1, n = 108). The ICC showed very high reliability (ICC = 0.988, n = 21). The Huet questionnaire is an easy, rapidly administered tool that correlated highly with [Formula: see text] in this sample population. Key words: physical activity, epidemiology, evaluation


2020 ◽  
pp. 1-13
Author(s):  
Louise Capling ◽  
Janelle A. Gifford ◽  
Kathryn L. Beck ◽  
Victoria M. Flood ◽  
Fiona Halar ◽  
...  

Abstract Diet quality indices are a practical, cost-effective method to evaluate dietary patterns, yet few have investigated diet quality in athletes. This study describes the relative validity and reliability of the recently developed Athlete Diet Index (ADI). Participants completed the electronic ADI on two occasions, 2 weeks apart, followed by a 4-d estimated food record (4-dFR). Relative validity was evaluated by directly comparing mean scores of the two administrations (mAdm) against scores derived from 4-dFR using Spearman’s rank correlation coefficient and Bland–Altman (B–A) plots. Construct validity was investigated by comparing mAdm scores and 4-dFR-derived nutrient intakes using Spearman’s coefficient and independent t test. Test–retest reliability was assessed using paired t test, intraclass correlation coefficients (ICC) and B–A plots. Sixty-eight elite athletes (18·8 (sd 4·2) years) from an Australian sporting institute completed the ADI on both occasions. Mean score was 84·1 (sd 15·2; range 42·5–114·0). The ADI had good reliability (ICC = 0·80, 95 % CI 0·69, 0·87; P < 0·001), and B–A plots (mean 1·9; level of agreement −17·8, 21·7) showed no indication of systematic bias (y = 4·57–0·03 × x) (95 % CI −0·2, 0·1; P = 0·70). Relative validity was evaluated in fifty athletes who completed all study phases. Comparison of mAdm scores with 4-dFR-derived scores was moderate (rs 0·69; P < 0·001) with no systematic bias between methods of measurement (y = 6·90–0·04 × x) (95 % CI −0·3, 0·2; P = 0·73). Higher scores were associated with higher absolute nutrient intake consistent with a healthy dietary pattern. The ADI is a reliable tool with moderate validity, demonstrating its potential for application to investigate the diet quality of athletes.


2019 ◽  
Vol 19 (3) ◽  
pp. 575-582
Author(s):  
Katariina P. Pirnes ◽  
Jouni Kallio ◽  
Kirsti Siekkinen ◽  
Harto Hakonen ◽  
Arja Häkkinen ◽  
...  

Abstract Background and aims There is a growing body of evidence, that pain is common at school age. Less is known about the repeatability of pain questionnaires for children. This study aimed to assess the test-retest repeatability of the Finnish version of the electronic pain questionnaire for school-aged children. Methods Primary (n = 79) and lower secondary (n = 127) schoolchildren aged 10–15 years from two schools from the Jyväskylä region of Finland, filled in an electronic questionnaire twice in an interval of 2 weeks. It captured the frequency of pain symptoms with a five-point Likert-scale questionnaire covering nine areas of the body for the last 3 months. The intraclass correlation coefficient (ICC) values 0.40–0.59 reflected fair and 0.60–0.74 good repeatability. Results The highest prevalences of pain were in the head (29%) and neck and shoulder (NS) (23%) areas. ICC values showed good repeatability for questions about pain frequency in the head, NS and lower extremities. In primary school, these values were good in the lower extremities and fair in NS, lower back and the head. In lower secondary school, the ICC values were good in NS and the head, fair in the stomach and lower extremities. Conclusions This electronic questionnaire was an acceptably repeatable indicator to measure the frequency of pain in the most prevalent pain areas: the head and NS. Implications It is important to be aware of the impact of health-related outcomes on children’s ability to be successful in their lives. With the help of a simple electronic questionnaire, it is possible to cost-effectively capture, for example, the prevalence and frequency of pain during the school hours. The identification of children’s pain symptoms accurately provides more possibilities to prevent and to minimize the chronic pain among schoolchildren.


Author(s):  
Joel S. Burma ◽  
Sarah Graver ◽  
Lauren N. Miutz ◽  
Alannah Macaulay ◽  
Paige V. Copeland ◽  
...  

Background: Ultra-short-term (UST) heart rate variability (HRV) metrics have increasingly been proposed as surrogates for short-term HRV metrics. However, the concurrent validity, within-day reliability, and between-day reliability of UST HRV have yet to be comprehensively documented. Methods: Thirty-six adults (18 males, age: 26 ± 5 years, BMI: 24 ± 3 kg/m2) were recruited. Measures of HRV were quantified in a quiet-stance upright orthostatic position via three-lead electrocardiogram (ADInstruments, FE232 BioAmp). All short-term data recordings were 300-seconds in length and five UST time points (i.e., 30-seconds, 60-seconds, 120-seconds, 180-seconds, and 240-seconds) were extracted from the original 300-second recording. Bland-Altman plots with 95% limits of agreement, repeated measures ANOVA, and two-tailed paired t-tests demarcated differences between UST and short-term recordings. Linear regressions, coefficient of variation, intraclass correlation coefficients, and other tests examined the validity and reliability in both time- and frequency-domains. Results: No group differences were noted between all short-term and UST measures, for either time- (all p>0.202) or frequency-domain metrics (all p>0.086). A longer recording duration was associated with augmented validity and reliability, that was less impacted by confounding influences from physiological variables (e.g., respiration rate, carbon dioxide end-tidals, and blood pressure). Conclusively, heart rate, time-domain, and relative frequency-domain HRV metrics were acceptable with recordings greater or equal to 60s, 240s, and 300s, respectively. Conclusions: Future studies employing UST HRV metrics, should thoroughly understand the methodological requirements to obtain accurate results. Moreover, a conservative approach should be utilized regarding the minimum acceptable recording duration, which ensures valid/reliable HRV estimates are obtained.


2002 ◽  
Vol 06 (03n04) ◽  
pp. 135-145 ◽  
Author(s):  
M. Friedrich

Because the degree and duration of lumbar flexion during sewage work have only been assessed on the basis of subjective reports, the purpose of this study was to investigate the usability of a measurement system for the non-invasive assessment of lumbar sagittal posture during sewage work using ultrasound. The validity of an ultrasonic measurement device was investigated in 16 healthy individuals by comparing the measurements obtained with the device with both Schober and electronic inclinometer measurements. To determine the intra-rater reliability of the ultrasonic device, short-term, medium-term, and long-term test-retest data were collected. Moreover, the percentage of the work time sewage workers spend in each of seven lumbar flexion categories within their individual lumbar flexion range of motion was assessed. Pearson's correlation coefficients of ≥ 0.88 indicate high validity between the methods. The intraclass correlation coefficients between tests and retests (≥ 0.88) demonstrate high reproducibility of the measurement procedures. Sewage workers spend about 25% of their work day in the most extreme of the seven lumbar posture categories. Also, testing did not interfere with the workers' normal work routine. The validity and reliability data as well as the trouble-free technical performance of the ultrasonic device support its usability for the continuous measurement of lumbar posture during sewage work.


Sign in / Sign up

Export Citation Format

Share Document