Electrochemical techniques

Author(s):  
Ram P. Lamsal ◽  
Diane Beauchemin
2019 ◽  
Author(s):  
Chem Int

The anti-corrosive properties of sulphadoxine + pyrimethamine (S+P) on the corrosion of pipeline steel in acidic environment were investigated using electrochemical techniques. The results obtained showed an excellent inhibition efficiency which increased with increase in inhibitor concentration. The corrosion inhibition efficiency increased up to 99.04 % at 0.01M S+P and decreased with rise in temperature down to 85.93 % at 333 K and 0.01 M S+P, suggesting a physiosorptive mechanism of adsorption. Also the adsorption data was fitted into Langmuir and Temkin adsorption isotherms, while the inhibitive action was shown to proceed by mixed inhibition mode.


2018 ◽  
Vol 69 (1) ◽  
pp. 112-115
Author(s):  
Ana Maria Popescu ◽  
Virgil Constantin

The cathodic behavior of Ce3+ ions in LiF-NaF-BaF2, LiF-NaF-NaCl and NaCl-KCl molten salts at 730� C has been studied using different electrochemical techniques. The decomposition potential (Ed) and the cathodic overvoltage were determined by introducing NaCeF4 as electrochemical active species using steady-state potential-current curves recorded under galvanostatic conditions. The values of |Ed| were 1.85 V in LiF-NaF-BaF2, 2.114 V in LiF-NaF-NaCl and 2.538 V in NaCl-KCl, respectively. It was also found that the ohmic drop potential in melt is not dependent on NaCeF4 concentration and it rises as the current intensity increases. The Tafel slopes and other kinetic parameters were calculated on the assumption that the cathodic process consisted of direct discharge of Ce3+, with no solvent-solute interaction. In order to elucidate the mechanisn of cathodic process the cyclic voltammetry technique was finally used. From the evolution of the voltammograms we conclude that the electrochemical reduction of Ce3+ ion is actually a reversible process on the molybdenum electrode and cathodic reduction of Ce3+ takes place in one single step involving three electron exchange. Our study adds to the accumulating data and confirms available results of electrodeposition of metalic cerium from molten salts using NaCeF4 as solute.


2020 ◽  
pp. 1-4
Author(s):  
CHARULATA SIVODIA ◽  
ALOK SINHA

The advancement made in biomedical industry upsurges the consumption rate of pharmaceutical drugs. The lack of proper monitoring and regulation methods leads to the unregulated discharge of pharmaceuticals in wastewater, where it can affect the aquatic organisms. Anticancer drugs are also known as cytostatic drugs mainly used for the treatment of cancer by disrupting the cell function and prevent multiplication of cancerous cell. Therefore, anticancer drugs are suspected to pose potential risk on environment by influencing mutagenic effects on the cells of aquatic organisms. An extensive research has been already made in the field of pharmaceutical removal, however their application on the removal of anticancer drugs is limited. This review paper elucidates about different electrochemical techniques for the mitigation of cytostatic drugs.


2019 ◽  
Vol 15 (4) ◽  
pp. 423-442 ◽  
Author(s):  
Mona Habibi-Kool-Gheshlaghi ◽  
Farnoush Faridbod ◽  
Mahya Karami Mosammam ◽  
Mohammad Reza Ganjali

Background: Tricyclic psychotropic drugs are defined as a tricyclic rings of the dibenzazepine group with the presence of sulfur and nitrogen atoms. They have been prescribed for antidepressive therapy over the years. Due to their medical importance, many analytical methods have been developed for their monitoring. However, benefits of electrochemical techniques such as costeffectiveness, fast, easy operation and non-destructiveness make them appropriate analytical methods for drug assays. Electrochemical determinations of pharmaceuticals require suitable working electrodes. During years, many electrodes are modified by a variety of modifiers and several sensors were developed based on them. In this regard, nanomaterials, due to their remarkable properties, are one of the most important choices. Objective: Here, the application of electroanalytical methods in the determination of electroactive tricyclic psychotropic drugs will be reviewed and the nanomaterials which are used for improvements of the working electrodes will be considered.


2019 ◽  
Vol 17 (1) ◽  
pp. 1087-1094
Author(s):  
Zora Pilić ◽  
Ivan Dragičević ◽  
Ivana Martinović

AbstractThe effect of Satureja montana L. extract (SM) and phenolic fraction of Satureja montana L. (PF) on the corrosion behaviour of iron in 0.1 mol L-1 sodium chloride solution was studied by electrochemical techniques, UV/Vis spectrophotometry and atomic absorption spectrometry. The results of all techniques showed that SM and PF contributed to iron corrosion inhibition. The calculated inhibition efficiency values were about 45% for SM and 55% for PF. Results indicate that the inhibitive action occurs via a precipitation of the Fe-complex onto the iron surface which resulting in a decrease of the passive current density. The atomic absorption spectrometry (AAS) method was applied to the quantitative determination of iron in solution. The obtained results demonstrated good agreement with results obtained by electrochemical techniques.


Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 416
Author(s):  
Zari Tehrani ◽  
Hina Yaqub Abbasi ◽  
Anitha Devadoss ◽  
Jonathan Edward Evans ◽  
Owen James Guy

Electrochemical biosensors using carbon-based electrodes are being widely developed for the detection of a range of different diseases. Since their sensitivity depends on the surface coverage of bioreceptor moieties, it necessarily depends on the surface coverage of amine precursors. Electrochemical techniques, using ferrocene carboxylic acid as a rapid and cheap assay, were used to assess the surface coverage of amino-phenyl groups attached to the carbon electrode. While the number of electrons transferred in the first step of diazotisation indicated a surface coverage of 8.02 ± 0.2 × l0−10 (mol/cm2), and those transferred in the second step, a reduction of nitrophenyl to amino-phenyl, indicated an amine surface coverage of 4–5 × l0−10 (mol/cm2), the number of electrons transferred during attachment of the amine coupling assay compound, ferrocene carboxylic acid, indicated a much lower available amine coverage of only 2.2 × l0−11 (mol/cm2). Furthermore, the available amine coverage was critically dependent upon the number of cyclic voltammetry cycles used in the reduction, and thus the procedures used in this step influenced the sensitivity of any subsequent sensor. Amine coupling of a carboxyl terminated anti-beta amyloid antibody specific to Aβ(1-42) peptide, a potential marker for Alzheimer’s disease, followed the same pattern of coverage as that observed with ferrocene carboxylic acid, and at optimum amine coverage, the sensitivity of the differential pulse voltammetry sensor was in the range 0–200 ng/mL with the slope of 5.07 µA/ng·mL−1 and R2 = 0.98.


2021 ◽  
Vol 23 (3) ◽  
pp. 1330-1336
Author(s):  
Genlai Du ◽  
Xia Hua ◽  
Bin Xu ◽  
Huan Wang ◽  
Xin Zhou ◽  
...  

We designed a technology to combined biotechnology, chemical and electrochemical techniques to achieve furoic acid bio-production from bio-toxic furfural.


2021 ◽  
Vol 11 (5) ◽  
pp. 2133
Author(s):  
Laura Landa-Ruiz ◽  
Miguel Angel Baltazar-Zamora ◽  
Juan Bosch ◽  
Jacob Ress ◽  
Griselda Santiago-Hurtado ◽  
...  

This research evaluates the behavior corrosion of galvanized steel (GS) and AISI 1018 carbon steel (CS) embedded in conventional concrete (CC) made with 100% CPC 30R and two binary sustainable concretes (BSC1 and BSC2) made with sugar cane bagasse ash (SCBA) and silica fume (SF), respectively, after 300 days of exposure to 3.5 wt.% MgSO4 solution as aggressive medium. Electrochemical techniques were applied to monitor corrosion potential (Ecorr) according to ASTM C-876-15 and linear polarization resistance (LPR) according to ASTM G59 for determining corrosion current density (icorr). Ecorr and icorr results indicate after more than 300 days of exposure to the sulfate environment (3.5 wt.% MgSO4 solution), that the CS specimens embedded in BSC1 and BSC2 presented greater protection against corrosion in 3.5 wt.% MgSO4 than the specimens embedded in CC. It was also shown that this protection against sulfates is significantly increased when using GS reinforcements. The results indicate a higher resistance to corrosion by exposure to 3.5 wt.% magnesium sulfate two times greater for BSC1 and BSC2 specimens reinforced with GS than the specimens embedding CS. In summary, the combination of binary sustainable concrete with galvanized steel improves durability and lifetime in service, in addition to reducing the environmental impact of the civil engineering structures.


Sign in / Sign up

Export Citation Format

Share Document