Design and performance of a countersunk screen in a maize cleaning device

2021 ◽  
Vol 209 ◽  
pp. 300-314
Author(s):  
Lijun Wang ◽  
Jin Chai ◽  
Housheng Wang ◽  
Yingshuai Wang
2021 ◽  
Author(s):  
Chris Idelson ◽  
John Uecker ◽  
James Garcia ◽  
Sunjna Kohli ◽  
Greta Handing ◽  
...  

Abstract A common tool for diagnosis and treatment of gastrointestinal, gynecologic, and other anatomical pathologies is a form of minimally invasive surgery known as laparoscopy. Roughly 4 million laparoscopic surgeries are performed in the US every year, with an estimated 15 million globally. During surgeries, lens clarity often becomes impaired via (1) condensation or (2) smearing of bodily fluids and tissues. The current gold standard solution requires scope removal from the body for cleaning, offering opportunity for decreased surgical safety and efficiency, while simultaneously generating mounting frustration for the operating room team. A novel lens cleaning device was designed and developed to clean a laparoscope lens in-vivo during surgery. Benchtop experiments in a warm body simulated environment allowed quantification of lens cleaning efficacy for several lens contaminants. Image analysis techniques detected differences between original (clean), post-debris, and post-cleaning images. Mechanical testing was also executed to determine safety levels regarding potential misuse scenarios. Compared to gold standard device technologies, the novel lens cleaning device prototype showed strong performance and ability to clear a laparoscope lens of debris while mitigating the need for scope removal from the simulated surgical cavity. Mechanical testing results also suggests the design also holds inherently strong safety performance. Both objective metrics and subjective observation suggests the novel design holds promise to improve safety and efficiency during laparoscopic surgery.


2021 ◽  
Vol 13 (11) ◽  
pp. 5846
Author(s):  
María Alonso-García ◽  
Ana García-Sánchez ◽  
Paula Jaén-Moreno ◽  
Manuel Fernández-Rubio

Presently, several jobs require the collaboration of humans and machines to perform different services and tasks. The ease and intuitiveness of the worker when using each machine will not only improve the worker’s experience but also improve the company’s productivity and the satisfaction that all users have. Specifically, electromechanical devices used to provide cleaning services require complex interactions. These interactions determine the usability and performance of devices. Therefore, devices must have appropriate ergonomic arrangements for human–machine interactions. Otherwise, the desired performance cannot be achieved. This study analyzes the performance of an urban cleaning device (pressure washer on a power take-off van) using human–machine interaction method. The method measures visceral and behavioral levels (set by Norman) and service times. Using these measurements, the usability of the pressure washer is determined according to different factors that facilitate the operator’s well-being in the working environment. A pressure washer from Feniks Cleaning and Safety, Limited Company, has been studied. Sixteen errors related to ergonomics, usability and safety were identified in this machine, which operates in more than 40 locations in Spain. Therefore, this study provides valuable information on the usability and performance of pressure washers, as well as possibilities for improvement.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


1986 ◽  
Vol 50 (5) ◽  
pp. 264-267 ◽  
Author(s):  
GH Westerman ◽  
TG Grandy ◽  
JV Lupo ◽  
RE Mitchell

2008 ◽  
Vol 17 (3) ◽  
pp. 87-92
Author(s):  
Leonard L. LaPointe

Abstract Loss of implicit linguistic competence assumes a loss of linguistic rules, necessary linguistic computations, or representations. In aphasia, the inherent neurological damage is frequently assumed by some to be a loss of implicit linguistic competence that has damaged or wiped out neural centers or pathways that are necessary for maintenance of the language rules and representations needed to communicate. Not everyone agrees with this view of language use in aphasia. The measurement of implicit language competence, although apparently necessary and satisfying for theoretic linguistics, is complexly interwoven with performance factors. Transience, stimulability, and variability in aphasia language use provide evidence for an access deficit model that supports performance loss. Advances in understanding linguistic competence and performance may be informed by careful study of bilingual language acquisition and loss, the language of savants, the language of feral children, and advances in neuroimaging. Social models of aphasia treatment, coupled with an access deficit view of aphasia, can salve our restless minds and allow pursuit of maximum interactive communication goals even without a comfortable explanation of implicit linguistic competence in aphasia.


Sign in / Sign up

Export Citation Format

Share Document