Extraction efficiency and characteristics of acid and pepsin soluble collagens from the skin of golden carp (Probarbus Jullieni) as affected by ultrasonication

2018 ◽  
Vol 66 ◽  
pp. 237-244 ◽  
Author(s):  
Ali Muhammed Moula Ali ◽  
Hideki Kishimura ◽  
Soottawat Benjakul
2008 ◽  
Vol 7 (1) ◽  
Author(s):  
Bimo Budi Santoso

<strong><em>Flavanoid, steroid, and terpenoid contents of 20 Manokwari medicinal plants were analyzed.  The antioxidant activity, total phenolic contents and antitumor activity of 20 Manokwari medicinal plants were also evaluated. The result shows that 83% positif to flavanoid test, 59% positif to terpenoid test and only 25% positif steroid. Antioxidant activity and total phenolic contents evaluated using Ferric Thiocianate (FTC) and Folin-Ciocalteu methods respectively. Antioxidant activity and total phenolic contents of medicinal plants were extracted by the traditional method, boiling in water and also in 80% methanol. Twenty plants evaluated in both exstracts have significantly varies of antioxidant activities and phenolic contents,  A significant and linier correlation coefficient between the antioxidant activity and the total phenolic content was found in both aqueous (R<sup>2</sup>= 0,77) and methanol (R<sup>2</sup> = 0,85). Antitumor activity was tested using cell maurine P-388 and only 2 of medicinal plants are active to inhibit cell maurine P-388. Comparing extraction efficiency of the two methods, the methanol extracted phenolic compounds more efficiently, and antioxidant activity of the extract was higher.</em></strong>


2012 ◽  
Vol 27 (7) ◽  
pp. 716-720
Author(s):  
Bing XU ◽  
Jun-Liang ZHAO ◽  
Jian-Ming ZHANG ◽  
Xiao-Wei SUN ◽  
Fu-Wei ZHUGE ◽  
...  

2020 ◽  
Vol 16 (7) ◽  
pp. 893-904
Author(s):  
Alessandra von Ahn ◽  
João Henrique Z. dos Santos

Background: The official compendium of the quantification of ginkgo flavonoids from Ginkgo biloba extract has been proposed using HPLC. The drawbacks of this technique appear to be due to the restricted efficiency in terms of the recovery results and suitability of the system for the quantification of these compounds. This study investigated the potential advantages and limitations of the development of efficient extraction methods for the recovery of flavonol glycosides (quercetin, kaempferol and isorhamnetin) and terpene trilactones (bilobalide, ginkgolide A, ginkgolide B and ginkgolide C) using extraction, quantification and detection techniques, namely, GC-FID and UHPLC-DAD, which are alternatives to those techniques available in the literature. Methods: Two different extraction methodologies have been developed for the determination of flavonoids (quercetin, kaempferol and isorhamnetin) and terpene trilactones (bilobalide, ginkgolide A, ginkgolide B and ginkgolide C) using ultra-high-pressure liquid chromatography coupled to a diode array detector and gas chromatography coupled to a flame ionization detector. Results: In this study, the Ginkgo biloba extract mass, hydrolysis preparation method (with or without reflux), and volume of the extraction solution seemed to affect the ginkgo flavonoid recovery. The UHPLC-based method exhibited higher extraction efficiency for ginkgo flavonoid quantification compared to the pharmacopoeial method. The developed method exhibited higher extraction efficiency for terpene quantification compared to the previous method that used extractive solution without pH adjustment, with less time of extraction and less amount of the sample and organic solvent aliquots. Conclusion: The UHPLC and GC analysis methods established in this study are both effective and efficient. These methods may improve the quality control procedures for ginkgo extract and commercial products available in today´s natural health product market. The results indicate that redeveloped extraction methods can be a viable alternative to traditional extraction methods.


2017 ◽  
Vol 6 (04) ◽  
pp. 5343
Author(s):  
Ragni Vora ◽  
Ambika N. Joshi* ◽  
Nitesh C. Joshi

Mucuna pruriens seeds are noted to be a natural source of L-DOPA and are also used as a substitute for the synthetic L-DOPA. In the present study; attempts are made to develop suitable method(s) for extraction of L-DOPA from the powdered seeds of Mucuna pruriens using different solvents and conditions. The Seed powder was subjected to 7 different extraction methods and Method 1 was subjected to various solvent concentrations. Some methods used de-fatting procedure, either the method was cold maceration or in high temperature. Soxhlet extraction was also used in one of the extraction methods. All the extracts were analyzed using RP-HPLC. Mobile Phase used was Water: Methanol: AcetoNitrile (100:60:40) (v/v) containing 0.2% Triethylamine, pH = 3.3 and monitored at 280 nm with variable wavelength UV detector. The extraction was best with Methanol Water mixture in a cold maceration technique and overall gives good extraction efficiency of 13.36 % L-DOPA and id the best method giving highest extraction efficiency. The De-fatting method was the 2nd best methods giving approximately 8.8% L-DOPA and Method 5 viz, heat reflux method gives 8.7% L-DOPA making it the 3rd best method. There are not many studies done for optimization of extraction technique for L-DOPA despite an extensive work is reported for isolation, identification and pharmacological activities of L-DOPA from various plant sources. Keeping this in view, present investigation was done to study the extraction efficiency of various extraction methods of L-DOPA content in seed extracts of Mucuna pruriens and compare it.


2000 ◽  
Vol 65 (7) ◽  
pp. 1073-1081 ◽  
Author(s):  
Valerie Holubová ◽  
Iva Chvílíčková ◽  
Vlastimil Kubáň

Extraction procedures (steam distillation, supercritical fluid extraction and solvent extraction) for isolation of monoterpene hydrocarbons from fresh needles of Picea abies and Picea omorica were optimised. The procedures were compared with the aim of minimizing consumption of needles and improving the extraction efficiency and repeatability. An influence of homogenisation procedures and storage conditions (liquid nitrogen, -18 and 4 °C) on the total content and composition of essential oils was studied. Cryogenic grinding (liquid nitrogen) combined with the extraction with cold hexane (extraction time 2 h) and subsequent GC-MS determination in freshly homogenised needles gives the best results (1.5-4 times better extraction efficiency, RSD < 10% for P. abies and < 25% for P. omorica). Limits of detections (3 S/N) for individual monoterpene hydrocarbons from units to tens of ng/g and recoveries 97.2-101.4% were found in fresh needles (calculated to fresh weight). While cooling to 4 °C is unacceptable, freezing at -18 °C for the period of 18 days in the dark gives also good results.


2014 ◽  
Vol 6 (14) ◽  
pp. 5120-5126 ◽  
Author(s):  
Zhifeng Guo ◽  
Xiaoyang Wu ◽  
Jingjing Dong ◽  
Hiudan Su ◽  
Ru Cai

The objective of this paper is to use electrospun nanofibers as the adsorbents in solid phase extraction (SPE) to improve the extraction efficiency.


2020 ◽  
Vol 44 (6) ◽  
pp. 580-588
Author(s):  
A López-Rabuñal ◽  
E Lendoiro ◽  
M Concheiro ◽  
M López-Rivadulla ◽  
A Cruz ◽  
...  

Abstract An LC–MS-MS method for the determination of 14 benzodiazepines (BZDs) (alprazolam, α-hydroxyalprazolam, clonazepam, bromazepam, diazepam, nordiazepam, lorazepam, lormetazepam, oxazepam, flunitrazepam, 7-aminoflunitrazepam, triazolam, midazolam and zolpidem) and 15 antidepressants (ADs) (amitriptyline, nortriptyline, imipramine, desipramine, clomipramine, norclomipramine, fluoxetine, norfluoxetine, sertraline, norsertraline, paroxetine, venlafaxine, desmethylvenlafaxine, citalopram and desmethylcitalopram) in meconium was developed and validated. Meconium samples (0.25 ± 0.02 g) were homogenized in methanol and subjected to mixed-mode cation exchange solid-phase extraction. Chromatographic separation was performed in reversed phase, with a gradient of 0.1% formic acid in 2 mM ammonium formate and acetonitrile. Two different chromatographic gradient methods were employed, one for the separation of ADs and another for BZDs. Analytes were monitored by tandem mass spectrometry employing electrospray positive mode in MRM mode (2 transitions per compound). Method validation included: linearity [n = 5, limit of quantification (LOQ) to 400 ng/g], limits of detection (n = 6, 1–20 ng/g), LOQ (n = 9, 5–20 ng/g), selectivity (no endogenous or exogenous interferences), accuracy (n = 15, 90.6–111.5%), imprecision (n = 15, 0–14.6%), matrix effect (n = 10, −73 to 194.9%), extraction efficiency (n = 6, 35.9–91.2%), process efficiency (n = 6, 20.1–188.2%), stability 72 h in the autosampler (n = 3, −8.5 to 9%) and freeze/thaw stability (n = 3, −1.2 to −47%). The method was applied to four meconium specimens, which were analyzed with and without hydrolysis (enzymatic and alkaline). The authentic meconium samples tested positive for alprazolam, α-hydroxyalprazolam, clonazepam, diazepam, nordiazepam, fluoxetine, norfluoxetine, clomipramine and norclomipramine. Therefore, the present LC–MS-MS method allows a high throughput determination of the most common BZDs and ADs in meconium, which could be useful in clinical and forensic settings.


Sign in / Sign up

Export Citation Format

Share Document