scholarly journals Comparison of high-frequency in-pipe SARS-CoV-2 wastewater-based surveillance to concurrent COVID-19 random clinical testing on a public U.S. university campus

Author(s):  
Jillian Wright ◽  
Erin M. Driver ◽  
Devin A. Bowes ◽  
Bridger Johnston ◽  
Rolf U. Halden
1996 ◽  
Vol 78 (3) ◽  
pp. 871-880 ◽  
Author(s):  
Emma Otta ◽  
Paulo Reinhardt Santana ◽  
Luciana Menin Lafraia ◽  
Rachel Lenneberg Hoshino ◽  
Renata Plaza Teixeira ◽  
...  

The purpose was to analyze gender differences in the graffiti written on restroom walls by Brazilian students. We compared graffiti produced by men and women at secondary schools and on the university campus. We expected that the gender gap would be narrower in the older and more schooled group of undergraduates. Of the total of 1349 graffiti collected in 56 restroom stalls, 37% came from the university and 63% from secondary schools. At secondary schools we found less graffiti in women's than in men's restrooms, but no significant difference on the university campus In both places romantic contents predominated in women's restrooms but in men's restrooms they were virtually absent. A striking finding, which is contrary to previous studies, was the high frequency of sexual graffiti in women's restrooms on campus, comparable to that found in men's restrooms. Sex became a more central theme of both men's and women's graffiti on campus than in secondary schools. On the whole, a greater number of categories distinguished the sexes at the secondary school than on campus (7 vs 2). This supports the hypothesis of a narrower gender gap with increasing education.


2011 ◽  
Vol 403-408 ◽  
pp. 823-829
Author(s):  
Musfira Jilani ◽  
Padraig Corcoran ◽  
Peter Mooney

This paper investigates the effectiveness of using lampposts, which are commonly found in University campus environments with high frequency, as landmarks in a 2D LIDAR based Simultaneous Localization and Mapping (SLAM) framework. Lampposts offer a number of benefits compared to other forms of landmarks. Their unique spatial signature makes it possible to design effective algorithms to extract them. They have a very small spatial size. Their use removes the challenge of determining a corresponding location between difference views. This represents a major challenge if larger objects are used as landmarks. The proposed SLAM algorithm contains three stages. Firstly LIDAR segmentation is performed. Next each object is input to a binary classifier which determines objects with a high probability of corresponding to lampposts. Finally these extracted lampposts are input to an Iterative Closest Point (ICP) based SLAM algorithm. The ICP algorithm used is an extension of the traditional ICP algorithm and filters associations due to noise. Results achieved by the proposed system were very positive. An accurate map of a university’s lampposts was created and localization, when compared to GPS ground-truth, was very accurate.


2021 ◽  
Author(s):  
Sean M. Cavany ◽  
Aaron Bivins ◽  
Zhenyu Wu ◽  
Devin North ◽  
Kyle Bibby ◽  
...  

Since the start of the COVID-19 pandemic, there has been interest in using wastewater monitoring as an approach for disease surveillance. A significant uncertainty that would improve interpretation of wastewater monitoring data is the intensity and timing with which individuals shed RNA from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) into wastewater. By combining wastewater and case surveillance data sets from a university campus during a period of heightened surveillance, we inferred that individual shedding of RNA into wastewater peaks on average six days (50% uncertainty interval (UI): 6 - 7; 95% UI: 4 - 8) following infection, and is highly overdispersed (negative binomial dispersion parameter, k = 0.39 (95% credible interval: 0.32 - 0.48)). This limits the utility of wastewater surveillance as a leading indicator of secular trends in SARS-CoV-2 transmission during an epidemic, and implies that it could be most useful as an early warning of rising transmission in areas where transmission is low or clinical testing is delayed or of limited capacity.


2021 ◽  
Author(s):  
Smruthi Karthikeyan ◽  
Joshua I Levy ◽  
Peter De Hoff ◽  
Greg Humphrey ◽  
Amanda Birmingham ◽  
...  

As SARS-CoV-2 becomes an endemic pathogen, detecting emerging variants early is critical for public health interventions. Inferring lineage prevalence by clinical testing is infeasible at scale, especially in areas with limited resources, participation, or testing/sequencing capacity, which can also introduce biases. SARS-CoV-2 RNA concentration in wastewater successfully tracks regional infection dynamics and provides less biased abundance estimates than clinical testing. Tracking virus genomic sequences in wastewater would improve community prevalence estimates and detect emerging variants. However, two factors limit wastewater-based genomic surveillance: low-quality sequence data and inability to estimate relative lineage abundance in mixed samples. Here, we resolve these critical issues to perform a high-resolution, 295-day wastewater and clinical sequencing effort, in the controlled environment of a large university campus and the broader context of the surrounding county. We develop and deploy improved virus concentration protocols and deconvolution software that fully resolve multiple virus strains from wastewater. We detect emerging variants of concern up to 14 days earlier in wastewater samples, and identify multiple instances of virus spread not captured by clinical genomic surveillance. Our study provides a scalable solution for wastewater genomic surveillance that allows early detection of SARS-CoV-2 variants and identification of cryptic transmission.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


2019 ◽  
Vol 28 (1S) ◽  
pp. 209-224 ◽  
Author(s):  
Julia Campbell ◽  
Alison LaBrec ◽  
Connor Bean ◽  
Mashhood Nielsen ◽  
Won So

2020 ◽  
Vol 29 (3) ◽  
pp. 429-435
Author(s):  
Patricia C. Mancini ◽  
Richard S. Tyler ◽  
Hyung Jin Jun ◽  
Tang-Chuan Wang ◽  
Helena Ji ◽  
...  

Purpose The minimum masking level (MML) is the minimum intensity of a stimulus required to just totally mask the tinnitus. Treatments aimed at reducing the tinnitus itself should attempt to measure the magnitude of the tinnitus. The objective of this study was to evaluate the reliability of the MML. Method Sample consisted of 59 tinnitus patients who reported stable tinnitus. We obtained MML measures on two visits, separated by about 2–3 weeks. We used two noise types: speech-shaped noise and high-frequency emphasis noise. We also investigated the relationship between the MML and tinnitus loudness estimates and the Tinnitus Handicap Questionnaire (THQ). Results There were differences across the different noise types. The within-session standard deviation averaged across subjects varied between 1.3 and 1.8 dB. Across the two sessions, the Pearson correlation coefficients, range was r = .84. There was a weak relationship between the dB SL MML and loudness, and between the MML and the THQ. A moderate correlation ( r = .44) was found between the THQ and loudness estimates. Conclusions We conclude that the dB SL MML can be a reliable estimate of tinnitus magnitude, with expected standard deviations in trained subjects of about 1.5 dB. It appears that the dB SL MML and loudness estimates are not closely related.


Sign in / Sign up

Export Citation Format

Share Document