Influence of the redox condition dynamics on the removal efficiency of a laboratory-scale constructed wetland

2005 ◽  
Vol 39 (1) ◽  
pp. 248-256 ◽  
Author(s):  
A. Wießner ◽  
U. Kappelmeyer ◽  
P. Kuschk ◽  
M. Kästner
Water ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1086
Author(s):  
Mario Licata ◽  
Roberto Ruggeri ◽  
Nicolò Iacuzzi ◽  
Giuseppe Virga ◽  
Davide Farruggia ◽  
...  

Dairy wastewater (DWW) contains large amounts of mineral and organic compounds, which can accumulate in soil and water causing serious environmental pollution. A constructed wetland (CW) is a sustainable technology for the treatment of DWW in small-medium sized farms. This paper reports a two-year study on the performance of a pilot-scale horizontal subsurface flow system for DWW treatment in Sicily (Italy). The CW system covered a total surface area of 100 m2 and treated approximately 6 m3 per day of wastewater produced by a small dairy farm, subsequent to biological treatment. Removal efficiency (RE) of the system was calculated. The biomass production of two emergent macrophytes was determined and the effect of plant growth on organic pollutant RE was recorded. All DWW parameters showed significant differences between inlet and outlet. For BOD5 and COD, RE values were 76.00% and 62.00%, respectively. RE for total nitrogen (50.70%) was lower than that of organic compounds. RE levels of microbiological parameters were found to be higher than 80.00%. Giant reed produced greater biomass than umbrella sedge. A seasonal variation in RE of organic pollutants was recorded due to plant growth rate Our findings highlight the efficient use of a CW system for DWW treatment in dairy-cattle farms.


2011 ◽  
Vol 1 (3) ◽  
pp. 179-184 ◽  
Author(s):  
Beenish Saba ◽  
Tariq Mahmood ◽  
Bushra Zaman ◽  
Imran Hashmi

Reclaimed wastewater reuse for irrigation to crop plants is evaluated in a laboratory-scale experiment to assess growth and water saving potential from natural resources. A prototype laboratory-scale treatment plant was established for this purpose with suspended and attached growth configurations. Chakwal wheat variety was selected to examine growth parameters. The removal of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) were evaluated to check the quality of treated water. It was found that a suspended growth sequencing batch bioreactor (SGSBBR) achieved 97% ± 2 removal efficiency over a 4 h hydraulic retention time (HRT). For an attached growth sequencing batch bioreactor (AGSBBR) results showed 98% ± 2 removal efficiencies with polyurethane. TN and TP removal efficiency was 58.7 ± 3% and 64 ± 4.8% in SGSBBR, 53 ± 0.17% and 67 ± 2.7% in polyurethane. AGSBBR enhanced performance with AGSBBR may be due to enforced anoxic/aerobic conditions in the inner layers of biofilm formed on biocarriers which facilitate the required metabolic conditions for treating high strength wastewater. Plant growth was visibly greater in SGSBBR treated wastewater than AGSBBR because of less nutrient removal.


Author(s):  
Paulo Fortes Neto ◽  
Nara Lucia Perondi Fortes ◽  
Elizabeth Da Costa Neves Fernandes de Almeida Duarte ◽  
Rita Do Amaral Fragoso ◽  
Ana Catarina Marcos Henriques ◽  
...  

  The study reports the performance of a sanitary effluent treatment constituted by a septic tank, anaerobic filter and constructed wetland. The study monitored nutrient’s, carbonaceous material’s and thermotolerant coliform’s (CT) removal efficiency during 12 months. The treatment system included a septic tank, an anaerobic filter and a horizontal subsurface flow constructed wetland cultivated with Typha spp. Effluent samples were monthly collected before and after the septic tank, anaerobic filter and wetland. The removal efficiency for N-NH+4 was 37.6%, 66.3% for total P, 37% for COD, 54% for BOD and 99.4% for CT. The anaerobic filter and wetland were more efficient than the septic tank. P-total reduction was higher in the constructed wetland than in the anaerobic filter. Climatic conditions influenced the evaluated constituent’s removal being the highest values during hot months.


2011 ◽  
Vol 347-353 ◽  
pp. 1930-1933 ◽  
Author(s):  
Usa Onthong ◽  
Pornpan Pungpo ◽  
Wikanda Thongnueakhaeng

The removal of the cadmium ion from aqueous solution was studied in batch experiments using five natural zeolites were obtained from South of Thailnd, Clinoptiolite, Mordenite, Willhensonite, Offretite and Ferrierite, on the basis of experimental models on laboratory scale. Clinoptiolite was used for preliminary study of the adsorption parameters. An hour contact time and 40 g/L of the ratio of zeolite per water sample are optimum adsorption parameters with an average cadmium removal efficiency of 91.68 %. The optimum adsorption conditions were then used for other four natural zeolites. The results show that the effective removal sequence can be listed as Offretite  Clinoptiolite > Willhensonite > Mordenite > Ferrierite. Clinoptiolite, Offretite and Willhensonite are successfully used to reduce significantly cadmium from sample water with removal efficiency ranging from of 87-92%, respectively. Accordingly, the natural zeolites are recommendable adsorbents for highly cadmium removal of industrial wastewater with low cost of wastewater treatments and environmentally friendly chemical processes.


2020 ◽  
Vol 71 (12) ◽  
pp. 1686
Author(s):  
Chen Chen ◽  
Nannan Zhang ◽  
Zhe Liu ◽  
Shuqing An ◽  
Dehua Zhao

Intermittent aeration (IA) has been widely used in constructed wetlands (CWs) because it is economical and results in high nitrogen removal efficiency (RE). The aim of this study was to identify whether IA (4hday–1; the recommended frequency according to previous studies) in a partial area (PIA) can improve nitrogen RE compared with IA applied throughout the CW (TIA). Three types of laboratory-scale vertical flow CWs were constructed: PIA, TIA and non-aerated (NA). PIA achieved a higher RE of total nitrogen than TIA and NA (mean RE 60.6 v. 45.2 and 37.4% respectively). In the PIA, the ammonia mono-oxygenase subunit A (amoA) gene was abundant in aerated areas, whereas the nitrate reductase gene narG and nitrite reductase genes nirK and nirS were abundant in anaerobic areas. The results of this study suggest that PIA is an effective strategy for nitrogen removal when applying aeration in CWs because it preserves a constant anaerobic area for denitrification.


2010 ◽  
Vol 37 (3) ◽  
pp. 496-501 ◽  
Author(s):  
K.N. Njau ◽  
M. Renalda

A horizontal subsurface flow constructed wetland (HSSFCW) was employed to remove tannins from the effluent of a tannins extracting company. Two HSSFCW cells with hydraulic retention time (HRT) of 9 d and packed with limestone were used. One cell without macrophytes was used as a control, while the second cell was planted with Phragmites mauritianus . Results indicated that HSSFCW was capable of treating tannin wastewater that has been seeded with primary facultative pond sludge. Tannins and chemical oxygen demand (COD) removal efficiency of 95.9% and 90.6% with outlet concentration of 27 mg/L and 86 mg/L, respectively, were obtained in the planted cell; while the tannins and COD removal efficiency of 91.1% and 89.5% with outlet concentration of 57 mg/L and 96 mg/L, respectively, were obtained in the control cell.


2010 ◽  
Vol 61 (12) ◽  
pp. 3017-3025 ◽  
Author(s):  
X. L. Shi ◽  
X. B. Hu ◽  
Z. Wang ◽  
L. L. Ding ◽  
H. Q. Ren

A laboratory-scale anaerobic-anoxic-aerobic-moving bed biofilm reactor (A1-A2-O-MBBR) system was undertaken to treat coke plant wastewaters from two different factories (wastewater A and B). Wastewater B had higher BOD5/COD ratio and COD/TN ratio than wastewater A. The effects of reflux ratios on COD, TN and NH3-N removals were studied. Results indicated that, with the reflux ratio increased from 2 to 5, COD removals of wastewater A and wastewater B increased from 57.4% to 72.6% and 78.2% to 88.6%, respectively. Meanwhile, TN removals were also increased accompanying reflux ratio rise, from 53.1% to 74.4% for wastewater A and 64.2% to 83.5% for wastewater B. At the same reflux ratio, compared with wastewater A, higher COD and TN removal efficiencies were observed in wastewater B, which had higher BOD5/COD and COD/TN ratio. Reflux ratio had no significant influence on NH3-N removal; 99.0% of the overall NH3-N removal efficiency was achieved by the system for both coke plant wastewaters at any tested reflux ratio. MBBR was effective in NH3-N removal, and about 95% of the NH3-N was removed in the MBBR.


Sign in / Sign up

Export Citation Format

Share Document