Numerical Investigation on the Effect of the Size and Number of Stages on the Tesla Microvalve Efficiency

2013 ◽  
Vol 29 (3) ◽  
pp. 527-534 ◽  
Author(s):  
K. Mohammadzadeh ◽  
E. M. Kolahdouz ◽  
E. Shirani ◽  
M. B. Shafii

AbstractIn the present study, the effect of the number of stages of Tesla Micro-Valve (TMV), as well as the dependency of Reynolds number, Re, on the valve performance has been analyzed. For this purpose, different layouts include one to four-stage with different sizes are investigated numerically. The main criterion for evaluation of valves performance is diodicity, Di. Unsteady and steady flow in valve have been simulated and compared. It is shown that although there are some difference but the trend is similar for both responses. Finally, 2-D and steady state computations of the fluid flow have been utilized that reveal a strong dependence of Di on Re and pressure drop, ΔP. The results showed that the maximum Di of the two-stage microvalve is approximately 1.45 times of that of one-stage. Additional stages increase the complexity, and they do not change Di appreciably. It is concluded that two-stage layout of Tesla type valve is the best option. Also, the two-stage valve performance for three different sizes is compared with Nozzle-Diffuser type Micro-Valve (NDMV). Comparisons, which are performed based on calculation Di in applicable range of Re, showed that Di as a function of Re is independent of the valve size. Also, the superiority of the Tesla type valve at higher Re and its weakness at lower Re is observed.

2018 ◽  
Vol 7 (4.35) ◽  
pp. 148 ◽  
Author(s):  
Nur Irmawati Om ◽  
Rozli Zulkifli ◽  
P. Gunnasegaran

The influence of utilizing different nanofluids types on the liquid cold plate (LCP) is numerically investigated. The thermal and fluid flow performance of LCP is examined by using pure ethylene glycol (EG), Al2O3-EG and CuO-EG. The volume fraction of the nanoparticle for both nanofluid is 2%. The finite volume method (FVM) has been used to solved 3-D steady state, laminar flow and heat transfer governing equations. The presented results indicate that Al2O3-EG able to provide the lowest surface temperature of the heater block followed by CuO-EG and EG, respectively. It is also found that the pressure drop and friction factor are higher for Al2O3-EG and CuO-EG compared to the pure EG.


2008 ◽  
Vol 10 (3) ◽  
pp. 35-37 ◽  
Author(s):  
Sylwia Peryt-Stawiarska ◽  
Zdzisław Jaworski

Fluctuations of the non-Newtonian fluid flow in a Kenics static mixer: An experimental study The measurements for a Kenics static mixer were carried out using Laser Doppler Anemometer (LDA). The test fluid was non-Newtonian solution of CMC, Blanose type 9H4. The velocity data inside the 5th Kenics insert were collected for the axial components at five levels of Reynolds number, Re = 20 ÷ 120. Velocity fluctuations were also analyzed in the frequency domain, after processing them with the help of the Fast Fourier Transform (FFT) procedure. The spectra of fluctuations provided information about level of the fluctuations in the observed range of Reynolds number. The obtained data were then also used to plot the velocity profiles for the fifth insert of the Kenics mixer. It was concluded that in the investigated range of Reynolds numbers (Re = 20 ÷ 120) a strong dependence of the velocity profiles and the flow fluctuations on Reynolds number was observed.


SPE Journal ◽  
2018 ◽  
Vol 23 (05) ◽  
pp. 1603-1614 ◽  
Author(s):  
Wanjing Luo ◽  
Changfu Tang ◽  
Yin Feng

Summary This study aims to develop a semianalytical model to calculate the productivity index (PI) of a horizontal well with pressure drop along the wellbore. It has been indicated that by introducing novel definitions of horizontal-well permeability and conductivity, the equation of fluid flow along a horizontal well with pressure drop has the same form as the one for fluid flow in a varying-conductivity fracture. Thus, the varying-conductivity-fracture model and PI model can be used to obtain the PI of a horizontal well. Results indicate that the PI of a horizontal well depends on the interaction between horizontal-well conductivity, penetration ratio, and Reynolds number. New type curves of the penetration ratios with various combinations of parameters have been presented. A complete-penetration zone and a partial-penetration zone can be identified on the type curves. Based on the type curves, two examples have also been presented to illustrate the advantages of this work in optimizing parameters of horizontal wells.


2020 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
S. Hoseinzadeh ◽  
Ali Sohani ◽  
Saman Samiezadeh ◽  
H. Kariman ◽  
M.H. Ghasemi

Purpose This study aim to use the finite volume method to solve differential equations related to three-dimensional simulation of a solar collector. Modeling is done using ANSYS-fluent software program. The investigation is done for a photovoltaic (PV) solar cell, with the dimension of 394 × 84 mm2, which is the aluminum type and receives the constant heat flux of 800 W.m−2. Water is also used as the working fluid, and the Reynolds number is 500. Design/methodology/approach In the present study, the effect of fluid flow path on the thermal, electrical and fluid flow characteristics of a PV thermal (PVT) collector is investigated. Three alternatives for flow paths, namely, direct, curved and spiral for coolant flow, are considered, and a numerical model to simulate the system performance is developed. Findings The results show that the highest efficiency is achieved by the solar cell with a curved fluid flow path. Additionally, it is found that the curved path’s efficiency is 0.8% and 0.5% higher than that of direct and spiral paths, respectively. Moreover, the highest pressure drop occurs in the curved microchannel route, with around 260 kPa, which is 2% and 5% more than the pressure drop of spiral and direct. Originality/value To the best of the authors’ knowledge, there has been no study that investigates numerically heat transfer, fluid flow and electrical performance of a PV solar thermal cell, simultaneously. Moreover, the effect of the microchannel routes which are considered for water flow has not been considered by researchers so far. Taking all the mentioned points into account, in this study, numerical analysis on the effect of different microchannel paths on the performance of a PVT solar collector is carried. The investigation is conducted for the Reynolds number of 500.


2021 ◽  
Vol 13 (8) ◽  
pp. 168781402110407
Author(s):  
Hosny Abou-Ziyan ◽  
Reda Ameen ◽  
Khairy Elsayed

This paper presents the results of fluid flow and convection heat transfer in concentric and eccentric annuli between two cylinders using a three-dimensional computational fluid dynamics model. Effects of rotational speed ( n = 0, 150, 300, and 400 rpm) and eccentricity (ε = 0, 0.15, 0.3, 0.45, and 0.6) on axial and tangential velocity distribution, pressure drop and forced convection heat transfer are investigated for radii ratios (η) of 0.2, 0.4, 0.6, and 0.8, Reynolds number 2.0 × 103–1.236 × 105, Taylor number 1.47 × 106–1.6 × 1010, and Prandtl number 3.71–6.94. The parameters cover many applications, including rotary heat exchangers, mixers, agitators, etc. Nusselt numbers and friction factors for stationary and rotated concentric and eccentric annuli are correlated with four dimensionless numbers. The results revealed that when the speed of the inner cylinder increases from 0 to 400 rpm, the friction factor increases by 7.7%–103% for concentric and 8.2%–148% for eccentric annuli, whereas Nusselt number enhances by 37%–333% for concentric and 44%–340% for eccentric annuli. The radius ratio has a substantial effect on the heat transfer and pressure drop in annuli. The eccentricity enhances the heat transfer up to 12%, whereas its effect on the friction factor is not monotonic as it depends on Reynolds number, radii ratios, and rotational speed.


Author(s):  
Shian Li ◽  
Gongnan Xie ◽  
Bengt Sunden

Purpose – The employment of continuous ribs in a passage involves a noticeable pressure drop penalty, while other studies have shown that truncated ribs may provide a potential to reduce the pressure drop while keeping a significant heat transfer enhancement. The purpose of this paper is to perform computer-aided simulations of turbulent flow and heat transfer of a rectangular cooling passage with continuous or truncated 45-deg V-shaped ribs on opposite walls. Design/methodology/approach – Computational fluid dynamics technique is used to study the fluid flow and heat transfer characteristics in a three-dimensional rectangular passage with continuous and truncated V-shaped ribs. Findings – The inlet Reynolds number, based on the hydraulic diameter, is ranged from 12,000 to 60,000 and a low-Re k-e model is selected for the turbulent computations. The local flow structure and heat transfer in the internal cooling passages are presented and the thermal performances of the ribbed passages are compared. It is found that the passage with truncated V-shaped ribs on opposite walls provides nearly equivalent heat transfer enhancement with a lower (about 17 percent at high Reynolds number of 60,000) pressure loss compared to a passage with continuous V-shaped ribs or continuous transversal ribs. Research limitations/implications – The fluid is incompressible with constant thermophysical properties and the flow is steady. The passage is stationary. Practical implications – New and additional data will be helpful in the design of ribbed passages to achieve a good thermal performance. Originality/value – The results imply that truncated V-shaped ribs are very effective in improving the thermal performance and thus are suggested to be applied in gas turbine blade internal cooling, especially at high velocity or Reynolds number.


2013 ◽  
Vol 315 ◽  
pp. 93-97 ◽  
Author(s):  
Bukhari Manshoor ◽  
N.F. Rosidee ◽  
Amir Khalid

Fractal flow conditioner is a flow conditioner with a fractal pattern and used to eliminate turbulence originating from pipe fittings in experimental fluid flow applications. In this paper, steady state, incompressible, swirling turbulent flow through circle grid space filling fractal plate (Fractal flow conditioner) has been studied. The solution and the analysis were carried out using finite volume CFD solver FLUENT 6.2. The turbulence model used in this investigation is the standardk-εmodel and the results were compared with the pressure drop correlation of BS EN ISO 5167-2:2003. The results showed that the standardk-εmodel gave a good agreement with the ISO pressure drop correlation. Therefore, the model was used further to predict the effects of circle grids space filling plate thickness on the flow characteristics.


2020 ◽  
Vol 15 (2) ◽  
Author(s):  
Ranjith Kumar Valaparla ◽  
Karthik Balasubramanian ◽  
Kupireddy Kiran Kumar

AbstractPurpose: Numerical investigation was carried out to study the hydro-thermal characteristics in circular wavy microchannels (CWMCs) with sidewall rib. Thermal resistance and pressure drop penalty were compared with sinusoidal wavy microchannels (SWMCs) design. Parametric study on sidewall rib was also carried to minimize the pressure drop penalty and to achieve lower thermal resistance. Introducing sidewall rib in the CWMCs leads to the formation of more Deans vortices. This leads to an effective fluid mixing and augments the convective heat transfer. Design methodology/approach: A computational solid domain was created in SOLIDWORKS and the fluid domain was produced by circular arc profile for the entire length of heat sink. 3-D numerical investigation was carried out using ANSYS FLUENT software. Created computational domain was imported into ANSYS WORKBENCH. Meshing was executed in ANSYS mesh module. The computational domains were meshed using hexahedral elements adopting match control on both sides of microchannel (MC). The numerical investigation was carried out in the Re range from 100 to 300 with constant heat flux (50 W/cm2) applied at the bottom of the channel. Heat transfer and fluid flow characteristics were explained with velocity vectors, velocity contours and temperature contours. Findings: From numerical studies, it is concluded that CWMC with sidewall rib width (0.15 mm) leads to 33.6 % lower thermal resistance than SWMC with pressure drop penalty. Originality/Value: Present study is useful to identify the optimum deign to augment the heat dissipation performance of microchannel heat sink.