scholarly journals Combined Focused Ion Beam-Ultramicrotomy Method for TEM Specimen Preparation of Porous Fine-Grained Materials

2019 ◽  
Vol 26 (1) ◽  
pp. 120-125 ◽  
Author(s):  
Kenta K. Ohtaki ◽  
Hope A. Ishii ◽  
John P. Bradley

AbstractA new transmission electron microscopy (TEM) specimen preparation method that utilizes a combination of focused ion beam (FIB) methods and ultramicrotomy is demonstrated. This combined method retains the benefit of site-specific sampling by FIB but eliminates ion beam-induced damage except at specimen edges and allows recovery of many consecutive sections. It is best applied to porous and/or fine-grained materials that are amenable to ultramicrotomy but are located in bulk samples that are not. The method is ideal for unique samples from which every specimen is precious, and we demonstrate its utility on fine-grained material from the one-of-a-kind Paris meteorite. Compared with a specimen prepared by conventional FIB methods, the final sections are uniformly thin and free from re-deposition and curtaining artifacts common in FIB specimens prepared from porous, heterogeneous samples.

1999 ◽  
Vol 7 (2) ◽  
pp. 12-15 ◽  
Author(s):  
Lucille A. Giannuzzi ◽  
Richard Young ◽  
Pete Carleson

AbstractDriven by the analytical needs of microelectronics, magnetic media and micro-fabrication industries, focused ion beam (FIB) systems are now capable of milling and manipulating samples for the analysis of microstructure features having dimensions of 180 nm or less, A technique for locating and extracting site specific specimens for examination by transmission electron microscopy (TEM) has been developed. An identified feature can be located and precisely milled with an FIB system from two sides to prepare an ultrathin sample, and then extracted from the region with a glass rod micromanipulator onto a grid for TEM analysis. This specimen preparation method has been applied to semiconductor failure analysis and to the study of metallic and ceramic microsiructures with irregular topographies and complex mufti-layered components.


2000 ◽  
Vol 6 (S2) ◽  
pp. 528-529
Author(s):  
C. Urbanik Shannon ◽  
L. A. Giannuzzi ◽  
E. M. Raz

Automated specimen preparation for transmission electron microscopy has the obvious advantage of saving personnel time. While some people may perform labor intensive specimen preparation techniques quickly, automated specimen preparation performed in a timely and reproducible fashion can significantly improve the throughput of specimens in an industrial laboratory. The advent of focused ion beam workstations for the preparation of electron transparent membranes has revolutionized TEM specimen preparation. The FIB lift-out technique is a powerful specimen preparation method. However, there are instances where the “traditional” FIB method of specimen preparation may be more suitable. The traditional FIB method requires that specimens must be prepared so that the area of interest is as thin as possible (preferably less than 50 μm) prior to FIB milling. Automating the initial specimen preparation for brittle materials (e.g., Si wafers) may be performed using the combination of cleaving and sawing techniques as described below.


2005 ◽  
Vol 12 (2) ◽  
pp. 156-159 ◽  
Author(s):  
Leslie E. Thompson ◽  
Philip M. Rice ◽  
Eugene Delenia ◽  
Victor Y. Lee ◽  
Phillip J. Brock ◽  
...  

Ultramicrotomy, the technique of cutting nanometers-thin slices of material using a diamond knife, was applied to prepare transmission electron microscope (TEM) specimens of nanoporous poly(methylsilsesquioxane) (PMSSQ) thin films. This technique was compared to focused ion beam (FIB) cross-section preparation to address possible artifacts resulting from deformation of nanoporous microstructure during the sample preparation. It was found that ultramicrotomy is a successful TEM specimen preparation method for nanoporous PMSSQ thin films when combined with low-energy ion milling as a final step. A thick, sacrificial carbon coating was identified as a method of reducing defects from the FIB process which included film shrinkage and pore deformation.


2018 ◽  
Author(s):  
C.S. Bonifacio ◽  
P. Nowakowski ◽  
M.J. Campin ◽  
M.L. Ray ◽  
P.E. Fischione

Abstract Transmission electron microscopy (TEM) specimens are typically prepared using the focused ion beam (FIB) due to its site specificity, and fast and accurate thinning capabilities. However, TEM and high-resolution TEM (HRTEM) analysis may be limited due to the resulting FIB-induced artifacts. This work identifies FIB artifacts and presents the use of argon ion milling for the removal of FIB-induced damage for reproducible TEM specimen preparation of current and future fin field effect transistor (FinFET) technologies. Subsequently, high-quality and electron-transparent TEM specimens of less than 20 nm are obtained.


Author(s):  
H. J. Bender ◽  
R. A. Donaton

Abstract The characteristics of an organic low-k dielectric during investigation by focused ion beam (FIB) are discussed for the different FIB application modes: cross-section imaging, specimen preparation for transmission electron microscopy, and via milling for device modification. It is shown that the material is more stable under the ion beam than under the electron beam in the scanning electron microscope (SEM) or in the transmission electron microscope (TEM). The milling of the material by H2O vapor assistance is strongly enhanced. Also by applying XeF2 etching an enhanced milling rate can be obtained so that both the polymer layer and the intermediate oxides can be etched in a single step.


Author(s):  
K. Doong ◽  
J.-M. Fu ◽  
Y.-C. Huang

Abstract The specimen preparation technique using focused ion beam (FIB) to generate cross-sectional transmission electron microscopy (XTEM) samples of chemical vapor deposition (CVD) of Tungsten-plug (W-plug) and Tungsten Silicides (WSix) was studied. Using the combination method including two axes tilting[l], gas enhanced focused ion beam milling[2] and sacrificial metal coating on both sides of electron transmission membrane[3], it was possible to prepare a sample with minimal thickness (less than 1000 A) to get high spatial resolution in TEM observation. Based on this novel thinning technique, some applications such as XTEM observation of W-plug with different aspect ratio (I - 6), and the grain structure of CVD W-plug and CVD WSix were done. Also the problems and artifacts of XTEM sample preparation of high Z-factor material such as CVD W-plug and CVD WSix were given and the ways to avoid or minimize them were suggested.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Chin Kai Liu ◽  
Chi Jen. Chen ◽  
Jeh Yan.Chiou ◽  
David Su

Abstract Focused ion beam (FIB) has become a useful tool in the Integrated Circuit (IC) industry, It is playing an important role in Failure Analysis (FA), circuit repair and Transmission Electron Microscopy (TEM) specimen preparation. In particular, preparation of TEM samples using FIB has become popular within the last ten years [1]; the progress in this field is well documented. Given the usefulness of FIB, “Artifact” however is a very sensitive issue in TEM inspections. The ability to identify those artifacts in TEM analysis is an important as to understanding the significance of pictures In this paper, we will describe how to measure the damages introduced by FIB sample preparation and introduce a better way to prevent such kind of artifacts.