scholarly journals Determination of an Intermediate Perturbed Orbit using Multiple Observations

2014 ◽  
Vol 9 (S310) ◽  
pp. 166-167
Author(s):  
Vladimir A. Shefer

AbstractTwo methods are briefly stated for finding the preliminary orbit of a small celestial body from its three or more pairs of angular measurements and the corresponding time instants. The methods are based on using the approach that we previously developed for constructing the intermediate orbit from a minimum number of observations. This intermediate orbit allows for most of the perturbations in the motion of the body under study. The methods proposed use the Herget's algorithmic scheme that makes it possible to involve additional observations as well. Using the determination of orbits of some asteroids as examples, we compare the results obtained by applying the Herget multiple-observation algorithm and the proposed methods. The comparison shows that the proposed methods are an efficient means for studying perturbed motion. They are especially advantageous if applied to high-precision observational data covering short orbital arcs.

Author(s):  
K. Z. Botros ◽  
S. S. Sheinin

The main features of weak beam images of dislocations were first described by Cockayne et al. using calculations of intensity profiles based on the kinematical and two beam dynamical theories. The feature of weak beam images which is of particular interest in this investigation is that intensity profiles exhibit a sharp peak located at a position very close to the position of the dislocation in the crystal. This property of weak beam images of dislocations has an important application in the determination of stacking fault energy of crystals. This can easily be done since the separation of the partial dislocations bounding a stacking fault ribbon can be measured with high precision, assuming of course that the weak beam relationship between the positions of the image and the dislocation is valid. In order to carry out measurements such as these in practice the specimen must be tilted to "good" weak beam diffraction conditions, which implies utilizing high values of the deviation parameter Sg.


Author(s):  
T.B. Ball ◽  
W.M. Hess

It has been demonstrated that cross sections of bundles of hair can be effectively studied using image analysis. These studies can help to elucidate morphological differences of hair from one region of the body to another. The purpose of the present investigation was to use image analysis to determine whether morphological differences could be demonstrated between male and female human Caucasian terminal scalp hair.Hair samples were taken from the back of the head from 18 caucasoid males and 13 caucasoid females (Figs. 1-2). Bundles of 50 hairs were processed for cross-sectional examination and then analyzed using Prism Image Analysis software on a Macintosh llci computer. Twenty morphological parameters of size and shape were evaluated for each hair cross-section. The size parameters evaluated were area, convex area, perimeter, convex perimeter, length, breadth, fiber length, width, equivalent diameter, and inscribed radius. The shape parameters considered were formfactor, roundness, convexity, solidity, compactness, aspect ratio, elongation, curl, and fractal dimension.


2018 ◽  
Vol 30 (3) ◽  
pp. 167-173

Red colored lipstick is the most widely used cosmetic product. Although lipstick gives a lot of social, psychological and therapeutic benefits, it may harm the consumers. Because some lipsticks contain a considerable amount of heavy metal especially lead. Lead is being used in lipstick mainly for the pigments required to obtain needed colors. Lead accumulates in the body over time and lead-containing lipstick applied several times a day, every day, combined with lead in water and other sources, could add up to significant exposure levels. Therefore, this study was aimed to determine lead content in red colored lipsticks from market. This study was laboratorybased, analytical study by using 25 lipstick samples. Red colored lipsticks were bought from Mandalay Market by random sampling procedure and they were completely coded to avoid the bias. Then, lead content in coded samples was determined by Flame AAS according to International Conference on Harmonization (ICH) guideline. Lead contents of 88% of the lipsticks samples were more than specified limit (20 ppm) of Food and Drug Administration, United States. All of them, lead content was highest in counterfeit lipsticks group. Among the tested lipstick samples, lipstick with lowest lead content was LE-RL 01 (15.74 ppm) and the lipstick with highest lead content was CF-RL 01(60.09 ppm). In conclusion, lead contents of red colored lipsticks (22 out of 25) from market samples were higher than allowable limit (20 ppm).


2020 ◽  
pp. 73-75
Author(s):  
B.M. Bazrov ◽  
T.M. Gaynutdinov

The selection of technological bases is considered before the choice of the type of billet and the development of the route of the technological process. A technique is proposed for selecting the minimum number of sets of technological bases according to the criterion of equality in the cost price of manufacturing the part according to the principle of unity and combination of bases at this stage. Keywords: part, surface, coordinating size, accuracy, design and technological base, labor input, cost price. [email protected]


2017 ◽  
Vol 68 (4) ◽  
pp. 666-670 ◽  
Author(s):  
Mirela Mihon ◽  
Catalin Stelian Tuta ◽  
Alina Catrinel Ion ◽  
Dana Niculae ◽  
Vasile Lavric

The aim of this work was the development and validation of a fast analytical method to determine the residual solvents content in radiopharmaceuticals such as: 18F-Fluorodeoxyglucose (18F-FDG), 18F-Fluoroestradiol (18F-FES), 18F-Fluorothymidine (18F-FLT),18F-Fluoromisonidazole (18F-FMISO). Radiopharmaceuticals are radioactive preparations for medical purposes used in nuclear medicine as tracers in diagnostic imaging and treatment of certain diseases. Positron Emission Tomography (PET) is a medical imaging technique that consists in introducing into the body of a small amount of a biologically active chemical compound labelled with a short lived positron-emitting radioisotope (18F, 11C, 68Ga). Residual solvents are critical impurities in radiopharmaceuticals that can affect labelling, stability and physicochemical properties of drugs. Therefore, the determination of these solvents is essential for quality control of radiopharmaceuticals. Validation of the control method for residual solvents by gas chromatography is referred by the European Pharmacopoeia using a special injection technique (head space). The parameters of the method, which comply with International Conference on Harmonization guidelines, are: accuracy, precision, linearity, limit of detection, limit of quantification and robustness. The proposed method (direct gas chromatography injection) proved to be linear, precise, accurate and robust. Good linearity was achieved for all the solvents and correlation coefficients (R2) for each residual solvent were found more than 0.99.


Author(s):  
E.A. Derkach , O.I. Guseva

Objectives: to compare the accuracy of equations F.P. Hadlock and computer programs by V.N. Demidov in determining gestational age and fetal weight in the third trimester of gestation. Materials: 328 patients in terms 36–42 weeks of gestation are examined. Ultrasonography was performed in 0–5 days prior to childbirth. Results: it is established that the average mistake in determination of term of pregnancy when using the equation of F.P. Hadlock made 12,5 days, the computer program of V.N. Demidov – 4,4 days (distinction 2,8 times). The mistake within 4 days, when using the equation of F.P. Hadlock has met on average in 23,1 % of observations, the computer program of V.N. Demidov — 65,9 % (difference in 2,9 times). The mistake more than 10 days, took place respectively in 51,7 and 8,2 % (distinction by 6,3 times). At a comparative assessment of size of a mistake in determination of fetal mass it is established that when using the equation of F.P. Hadlock it has averaged 281,0 g, at application of the computer program of V.N. Demidov — 182,5 g (distinction of 54 %). The small mistake in the mass of a fetus which isn't exceeding 200 g at application of the equation of F.P. Hadlock has met in 48,1 % of cases and the computer program of V.N. Demidov — 64,0 % (distinction of 33,1 %). The mistake exceeding 500 g has been stated in 18 % (F.P. Hadlock) and 4,3 % (V.N. Demidov) respectively (distinction 4,2 times). Conclusions: the computer program of V.N. Demidov has high precision in determination of term of a gestation and mass of a fetus in the III pregnancy.


2021 ◽  
Vol 26 ◽  
pp. 100862
Author(s):  
Abrar Hussain ◽  
Lihao Yang ◽  
Shifeng Mao ◽  
Bo Da ◽  
Károly Tőkési ◽  
...  

1920 ◽  
Vol 44 (2) ◽  
pp. 211-213
Author(s):  
W. Prentice ◽  
H.O. Lund ◽  
H.G. Harbo

Sign in / Sign up

Export Citation Format

Share Document