One-step synthesis of silver nanoshells with bumps for highly sensitive near-IR SERS nanoprobes

2014 ◽  
Vol 2 (28) ◽  
pp. 4415-4421 ◽  
Author(s):  
Homan Kang ◽  
Jin-Kyoung Yang ◽  
Mi Suk Noh ◽  
Ahla Jo ◽  
Sinyoung Jeong ◽  
...  

Based on AgNSs with bump-structures, the NIR active, ultrasensitive, and biocompatible SERS probes were developed and applied forin vivocell tracking in a live animal.

2020 ◽  
Vol 1 (1) ◽  
Author(s):  
Maya Al-Sid-Cheikh ◽  
Steven J. Rowland ◽  
Ralf Kaegi ◽  
Theodore B. Henry ◽  
Marc-André Cormier ◽  
...  

AbstractAvailable analytical methods cannot detect nanoplastics at environmentally realistic concentrations in complex matrices such as biological tissues. Here, we describe a one-step polymerization method, allowing direct radiolabeling of a sulfonate end-capped nano-sized polystyrene (nPS; proposed as a model nanoplastic particle representing negatively charged nanoplastics). The method, which produces nanoplastics trackable in simulated environmental settings which have already been used to investigate the behavior of a nanoplastic in vivo in a bivalve mollusc, was developed, optimized and successfully applied to synthesis of 14C-labeled nPS of different sizes. In addition to a description of the method of synthesis, we describe the details for quantification, mass balance and recovery of the labelled particles from complex matrices offered by the radiolabelling approach. The radiolabeling approach described here, coupled to use of a highly sensitive autoradiographic method for monitoring nanoplastic body burden and distributions, may provide a valuable procedure for investigating the environmental pathways followed by negatively charged nanoplastics at low predicted environmental concentrations. Whether the behaviour of the synthetic nPS manufactured here, synthesised using a very common inititator, represents that of manufactured nPS found in the environment, remains to be seen.


2002 ◽  
Vol 10 (5) ◽  
pp. 1451-1458 ◽  
Author(s):  
Sophie Martel ◽  
Jean-Louis Clément ◽  
Agnès Muller ◽  
Marcel Culcasi ◽  
Sylvia Pietri

2021 ◽  
Vol 358 ◽  
pp. 109192
Author(s):  
Yajie Liang ◽  
Liset M. de la Prida

Genetics ◽  
1998 ◽  
Vol 149 (4) ◽  
pp. 1649-1663
Author(s):  
Oliver Z Nanassy ◽  
Kelly T Hughes

Abstract The Hin recombinase catalyzes a site-specific recombination reaction that results in the reversible inversion of a 1-kbp segment of the Salmonella chromosome. The DNA inversion reaction catalyzed by the Salmonella Hin recombinase is a dynamic process proceeding through many intermediate stages, requiring multiple DNA sites and the Fis accessory protein. Biochemical analysis of this reaction has identified intermediate steps in the inversion reaction but has not yet revealed the process by which transition from one step to another occurs. Because transition from one reaction step to another proceeds through interactions between specific amino acids, and between amino acids and DNA bases, it is possible to study these transitions through mutational analysis of the proteins involved. We isolated a large number of mutants in the Hin recombinase that failed to carry out the DNA exchange reaction. We generated genetic tools that allowed the assignment of these mutants to specific transition steps in the recombination reaction. This genetic analysis, combined with further biochemical analysis, allowed us to define contributions by specific amino acids to individual steps in the DNA inversion reaction. Evidence is also presented in support of a model that Fis protein enhances the binding of Hin to the hixR recombination site. These studies identified regions within the Hin recombinase involved in specific transition steps of the reaction and provided new insights into the molecular details of the reaction mechanism.


2020 ◽  
Vol 17 (1) ◽  
Author(s):  
Yang Zhang ◽  
Chunyang Dai ◽  
Huiyan Wang ◽  
Yong Gao ◽  
Tuantuan Li ◽  
...  

Abstract Background Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2, is posing a serious threat to global public health. Reverse transcriptase real-time quantitative polymerase chain reaction (qRT-PCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. Due to technical limitations, the reported positive rates of qRT-PCR assay of throat swab samples vary from 30 to 60%. Therefore, the evaluation of alternative strategies to overcome the limitations of qRT-PCR is required. A previous study reported that one-step nested (OSN)-qRT-PCR revealed better suitability for detecting SARS-CoV-2. However, information on the analytical performance of OSN-qRT-PCR is insufficient. Method In this study, we aimed to analyze OSN-qRT-PCR by comparing it with droplet digital PCR (ddPCR) and qRT-PCR by using a dilution series of SARS-CoV-2 pseudoviral RNA and a quality assessment panel. The clinical performance of OSN-qRT-PCR was also validated and compared with ddPCR and qRT-PCR using specimens from COVID-19 patients. Result The limit of detection (copies/ml) of qRT-PCR, ddPCR, and OSN-qRT-PCR were 520.1 (95% CI: 363.23–1145.69) for ORF1ab and 528.1 (95% CI: 347.7–1248.7) for N, 401.8 (95% CI: 284.8–938.3) for ORF1ab and 336.8 (95% CI: 244.6–792.5) for N, and 194.74 (95% CI: 139.7–430.9) for ORF1ab and 189.1 (95% CI: 130.9–433.9) for N, respectively. Of the 34 clinical samples from COVID-19 patients, the positive rates of OSN-qRT-PCR, ddPCR, and qRT-PCR were 82.35% (28/34), 67.65% (23/34), and 58.82% (20/34), respectively. Conclusion In conclusion, the highly sensitive and specific OSN-qRT-PCR assay is superior to ddPCR and qRT-PCR assays, showing great potential as a technique for detection of SARS-CoV-2 in patients with low viral loads.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Łukasz Kiraga ◽  
Paulina Kucharzewska ◽  
Damian Strzemecki ◽  
Tomasz P. Rygiel ◽  
Magdalena Król

Abstract In vivo tracking of administered cells chosen for specific disease treatment may be conducted by diagnostic imaging techniques preceded by cell labeling with special contrast agents. The most commonly used agents are those with radioactive properties, however their use in research is often impossible. This review paper focuses on the essential aspect of cell tracking with the exclusion of radioisotope tracers, therefore we compare application of different types of non-radioactive contrast agents (cell tracers), methods of cell labeling and application of various techniques for cell tracking, which are commonly used in preclinical or clinical studies. We discuss diagnostic imaging methods belonging to three groups: (1) Contrast-enhanced X-ray imaging, (2) Magnetic resonance imaging, and (3) Optical imaging. In addition, we present some interesting data from our own research on tracking immune cell with the use of discussed methods. Finally, we introduce an algorithm which may be useful for researchers planning leukocyte targeting studies, which may help to choose the appropriate cell type, contrast agent and diagnostic technique for particular disease study.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Melissa E. Monterosso ◽  
Kathryn Futrega ◽  
William B. Lott ◽  
Ian Vela ◽  
Elizabeth D. Williams ◽  
...  

AbstractProstate cancer (PCa) patient-derived xenografts (PDXs) are commonly propagated by serial transplantation of “pieces” of tumour in mice, but the cellular composition of pieces is not standardised. Herein, we optimised a microwell platform, the Microwell-mesh, to aggregate precise numbers of cells into arrays of microtissues, and then implanted the Microwell-mesh into NOD-scid IL2γ−/− (NSG) mice to study microtissue growth. First, mesh pore size was optimised using microtissues assembled from bone marrow-derived stromal cells, with mesh opening dimensions of 100×100 μm achieving superior microtissue vascularisation relative to mesh with 36×36 μm mesh openings. The optimised Microwell-mesh was used to assemble and implant PCa cell microtissue arrays (hereafter microtissues formed from cancer cells are referred to as microtumours) into mice. PCa cells were enriched from three different PDX lines, LuCaP35, LuCaP141, and BM18. 3D microtumours showed greater in vitro viability than 2D cultures, but neither proliferated. Microtumours were successfully established in mice 81% (57 of 70), 67% (4 of 6), 76% (19 of 25) for LuCaP35, LuCaP141, and BM18 PCa cells, respectively. Microtumour growth was tracked using live animal imaging for size or bioluminescence signal. If augmented with further imaging advances and cell bar coding, this microtumour model could enable greater resolution of PCa PDX drug response, and lead to the more efficient use of animals. The concept of microtissue assembly in the Microwell-mesh, and implantation in vivo may also have utility in implantation of islets, hair follicles or other organ-specific cells that self-assemble into 3D structures, providing an important bridge between in vitro assembly of mini-organs and in vivo implantation.


2020 ◽  
Vol 9 (5) ◽  
pp. 247-251
Author(s):  
Tilmann Sander ◽  
Anna Jodko-Władzińska ◽  
Stefan Hartwig ◽  
Rüdiger Brühl ◽  
Thomas Middelmann

AbstractThe electrophysiological activities in the human body generate electric and magnetic fields that can be measured noninvasively by electrodes on the skin, or even, not requiring any contact, by magnetometers. This includes the measurement of electrical activity of brain, heart, muscles and nerves that can be measured in vivo and allows to analyze functional processes with high temporal resolution. To measure these extremely small magnetic biosignals, traditionally highly sensitive superconducting quantum-interference devices have been used, together with advanced magnetic shields. Recently, they have been complemented in usability by a new class of sensors, optically pumped magnetometers (OPMs). These quantum sensors offer a high sensitivity without requiring cryogenic temperatures, allowing the design of small and flexible sensors for clinical applications. In this letter, we describe the advantages of these upcoming OPMs in two exemplary applications that were recently carried out at Physikalisch-Technische Bundesanstalt (PTB): (1) magnetocardiography (MCG) recorded during exercise and (2) auditory-evoked fields registered by magnetoencephalography.


2005 ◽  
Vol 49 (1) ◽  
pp. 380-387 ◽  
Author(s):  
Yan Q. Xiong ◽  
Julie Willard ◽  
Jagath L. Kadurugamuwa ◽  
Jun Yu ◽  
Kevin P. Francis ◽  
...  

ABSTRACT Therapeutic options for invasive Staphylococcus aureus infections have become limited due to rising antimicrobial resistance, making relevant animal model testing of new candidate agents more crucial than ever. In the present studies, a rat model of aortic infective endocarditis (IE) caused by a bioluminescently engineered, biofilm-positive S. aureus strain was used to evaluate real-time antibiotic efficacy directly. This strain was vancomycin and cefazolin susceptible but gentamicin resistant. Bioluminescence was detected and quantified daily in antibiotic-treated and control animals with IE, using a highly sensitive in vivo imaging system (IVIS). Persistent and increasing cardiac bioluminescent signals (BLS) were observed in untreated animals. Three days of vancomycin therapy caused significant reductions in both cardiac BLS (>10-fold versus control) and S. aureus densities in cardiac vegetations (P < 0.005 versus control). However, 3 days after discontinuation of vancomycin therapy, a greater than threefold increase in cardiac BLS was observed, indicating relapsing IE (which was confirmed by quantitative culture). Cefazolin resulted in modest decreases in cardiac BLS and bacterial densities. These microbiologic and cardiac BLS differences during therapy correlated with a longer time-above-MIC for vancomycin (>12 h) than for cefazolin (∼4 h). Gentamicin caused neither a reduction in cardiac S. aureus densities nor a reduction in BLS. There were significant correlations between cardiac BLS and S. aureus densities in vegetations in all treatment groups. These data suggest that bioluminescent imaging provides a substantial advance in the real-time monitoring of the efficacy of therapy of invasive S. aureus infections in live animals.


Sign in / Sign up

Export Citation Format

Share Document