Colorimetric analysis of the decomposition of S-nitrosothiols on paper-based microfluidic devices

The Analyst ◽  
2016 ◽  
Vol 141 (22) ◽  
pp. 6314-6320 ◽  
Author(s):  
Abdulghani Ismail ◽  
Marillya O. Araújo ◽  
Cyro L. S. Chagas ◽  
Sophie Griveau ◽  
Fanny D'Orlyé ◽  
...  

A disposable paper microfluidic device was developed to analyse different S-nitrosothiols simultaneously decomposed by Hg2+ as well as UV, Vis and IR lamps.

2021 ◽  
Author(s):  
Samantha Richardson ◽  
Alexander Iles ◽  
Jeanette M. Rotchell ◽  
Tim Charlson ◽  
Annabel Hanson ◽  
...  

We demonstrate how a combination of paper microfluidic devices and handheld mobile technology can be used by citizen scientists to carry out a sustained water monitoring campaign. We have developed a paper-based analysis device and a 3 minute sampling workflow that requires no more than a container, a test device and a smartphone app. The contaminant measured in these pilots are phosphates, detectable down to 3 mg L<sup>-1</sup>. Together these allow volunteers to successfully carry out cost-effective, high frequency, phosphate monitoring over an extended geographies and periods.


2021 ◽  
Author(s):  
Samantha Richardson ◽  
Alexander Iles ◽  
Jeanette M. Rotchell ◽  
Tim Charlson ◽  
Annabel Hanson ◽  
...  

We demonstrate how a combination of paper microfluidic devices and handheld mobile technology can be used by citizen scientists to carry out a sustained water monitoring campaign. We have developed a paper-based analysis device and a 3 minute sampling workflow that requires no more than a container, a test device and a smartphone app. The contaminant measured in these pilots are phosphates, detectable down to 3 mg L<sup>-1</sup>. Together these allow volunteers to successfully carry out cost-effective, high frequency, phosphate monitoring over an extended geographies and periods.


Lab on a Chip ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 3337-3343 ◽  
Author(s):  
N. Raj ◽  
V. Breedveld ◽  
D. W. Hess

A fully enclosed paper microfluidic device has been fabricated using pentafluoroethane (PFE) plasma deposition followed by O2 plasma etching.


2015 ◽  
Vol 7 (19) ◽  
pp. 8025-8033 ◽  
Author(s):  
Giacomo Musile ◽  
Ling Wang ◽  
Jashaun Bottoms ◽  
Franco Tagliaro ◽  
Bruce McCord

Colorimetric detection of morphine on a 6 channel paper microfluidic device.


Micromachines ◽  
2018 ◽  
Vol 9 (8) ◽  
pp. 387
Author(s):  
Carlos Toshiyuki Matsumi ◽  
Wilson José da Silva ◽  
Fábio Kurt Schneider ◽  
Joaquim Miguel Maia ◽  
Rigoberto E. M. Morales ◽  
...  

Microbubbles have various applications including their use as carrier agents for localized delivery of genes and drugs and in medical diagnostic imagery. Various techniques are used for the production of monodisperse microbubbles including the Gyratory, the coaxial electro-hydrodynamic atomization (CEHDA), the sonication methods, and the use of microfluidic devices. Some of these techniques require safety procedures during the application of intense electric fields (e.g., CEHDA) or soft lithography equipment for the production of microfluidic devices. This study presents a hybrid manufacturing process using micropipettes and 3D printing for the construction of a T-Junction microfluidic device resulting in simple and low cost generation of monodisperse microbubbles. In this work, microbubbles with an average size of 16.6 to 57.7 μm and a polydispersity index (PDI) between 0.47% and 1.06% were generated. When the device is used at higher bubble production rate, the average diameter was 42.8 μm with increased PDI of 3.13%. In addition, a second-order polynomial characteristic curve useful to estimate micropipette internal diameter necessary to generate a desired microbubble size is presented and a linear relationship between the ratio of gaseous and liquid phases flows and the ratio of microbubble and micropipette diameters (i.e., Qg/Ql and Db/Dp) was found.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7493
Author(s):  
Krystian L. Wlodarczyk ◽  
William N. MacPherson ◽  
Duncan P. Hand ◽  
M. Mercedes Maroto-Valer

In situ measurements are highly desirable in many microfluidic applications because they enable real-time, local monitoring of physical and chemical parameters, providing valuable insight into microscopic events and processes that occur in microfluidic devices. Unfortunately, the manufacturing of microfluidic devices with integrated sensors can be time-consuming, expensive, and “know-how” demanding. In this article, we describe an easy-to-implement method developed to integrate various “off-the-shelf” fiber optic sensors within microfluidic devices. To demonstrate this, we used commercial pH and pressure sensors (“pH SensorPlugs” and “FOP-MIV”, respectively), which were “reversibly” attached to a glass microfluidic device using custom 3D-printed connectors. The microfluidic device, which serves here as a demonstrator, incorporates a uniform porous structure and was manufactured using a picosecond pulsed laser. The sensors were attached to the inlet and outlet channels of the microfluidic pattern to perform simple experiments, the aim of which was to evaluate the performance of both the connectors and the sensors in a practical microfluidic environment. The bespoke connectors ensured robust and watertight connection, allowing the sensors to be safely disconnected if necessary, without damaging the microfluidic device. The pH SensorPlugs were tested with a pH 7.01 buffer solution. They measured the correct pH values with an accuracy of ±0.05 pH once sufficient contact between the injected fluid and the measuring element (optode) was established. In turn, the FOP-MIV sensors were used to measure local pressure in the inlet and outlet channels during injection and the steady flow of deionized water at different rates. These sensors were calibrated up to 140 mbar and provided pressure measurements with an uncertainty that was less than ±1.5 mbar. Readouts at a rate of 4 Hz allowed us to observe dynamic pressure changes in the device during the displacement of air by water. In the case of steady flow of water, the pressure difference between the two measuring points increased linearly with increasing flow rate, complying with Darcy’s law for incompressible fluids. These data can be used to determine the permeability of the porous structure within the device.


Author(s):  
Ahmed Fadl ◽  
Stefanie Demming ◽  
Zongqin Zhang ◽  
Bjo¨rn Hoxhold ◽  
Stephanus Bu¨ttgenbach ◽  
...  

Developing multifunctional devices are essential to realize more efficient Microsystems. With miniaturization processes taking place in many different applications, the rooms for single function microfluidic devices are limited. In this study, we introduce a multifunctional micro fluidic device based on bifurcation geometry which is capable of performing pumping and mixing at the same time. Optical lithography is used to fabricate the designed microfluidic device. The microfluidic device is tested at low actuator frequencies, and ethanol is employed as a working fluid. The operational principles are based on rectifying the oscillatory flows by using bifurcation structures for flow rectification. The results prove the feasibility of the novel design, and results are presented in terms of flow rates and maximum back pressures.


Sign in / Sign up

Export Citation Format

Share Document