scholarly journals Autonomous and complex flow control involving multistep injection and liquid replacement in a reaction chamber on steadily rotating centrifugal microfluidic devices

RSC Advances ◽  
2017 ◽  
Vol 7 (57) ◽  
pp. 35869-35874 ◽  
Author(s):  
Shunya Okamoto ◽  
Yoshiaki Ukita

This study demonstrates a novel autonomous flow-control technique using siphon-shaped microchannels on a steadily rotating centrifugal microfluidic device.

TECHNOLOGY ◽  
2017 ◽  
Vol 05 (01) ◽  
pp. 21-30 ◽  
Author(s):  
Brian M. Cummins ◽  
Rukesh Chinthapatla ◽  
Balaji Lenin ◽  
Frances S. Ligler ◽  
Glenn M. Walker

Simple fluid pumps have been developed to improve microfluidic device portability, but they cannot be easily programmed, produce repeatable pumping performance, or generate complex flow profiles — key requirements for increasing the functionality of portable microdevices. We present a detachable, paper-based, “hydraulic battery” that can be connected to the outlet of a microfluidic channel to pump fluid at varying flow rates over time, including step changes, ramping flows, and oscillating flows.


The Analyst ◽  
2021 ◽  
Author(s):  
Ilhoon Jang ◽  
Hyunwoong Kang ◽  
Simon Song ◽  
David S. Dandy ◽  
Brian J. Geiss ◽  
...  

We present novel flow control methods including valve, mixing control, and flow rate control applicable to the laminate capillary-driven microfluidic devices.


Sensors ◽  
2019 ◽  
Vol 19 (5) ◽  
pp. 1178 ◽  
Author(s):  
Jorge Prada ◽  
Christina Cordes ◽  
Carsten Harms ◽  
Walter Lang

This contribution outlines the design and manufacturing of a microfluidic device implemented as a biosensor for retrieval and detection of bacteria RNA. The device is fully made of Cyclo-Olefin Copolymer (COC), which features low auto-fluorescence, biocompatibility and manufacturability by hot-embossing. The RNA retrieval was carried on after bacteria heat-lysis by an on-chip micro-heater, whose function was characterized at different working parameters. Carbon resistive temperature sensors were tested, characterized and printed on the biochip sealing film to monitor the heating process. Off-chip and on-chip processed RNA were hybridized with capture probes on the reaction chamber surface and identification was achieved by detection of fluorescence tags. The application of the mentioned techniques and materials proved to allow the development of low-cost, disposable albeit multi-functional microfluidic system, performing heating, temperature sensing and chemical reaction processes in the same device. By proving its effectiveness, this device contributes a reference to show the integration potential of fully thermoplastic devices in biosensor systems.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1781
Author(s):  
Weiyu Lu ◽  
Xin Fu ◽  
Jinchun Wang ◽  
Yuanchi Zou

Vibration wall control is an important active flow control technique studied by many researchers. Although current researches have shown that the control performance is greatly affected by the frequency and amplitude of the vibration wall, the mechanism hiding behind the phenomena is still not clear, due to the complex interaction between the vibration wall and flow separation. To reveal the control mechanism of vibration walls, we propose a simplified model to help us understand the interaction between the forced excitation (from the vibration wall) and self-excitation (from flow instability). The simplified model can explain vibration wall flow control behaviors obtained by numerical simulation, which show that the control performance will be optimized at a certain reduced vibration frequency or amplitude. Also, it is shown by the analysis of maximal Lyapunov exponents that the vibration wall is able to change the flow field from a disordered one into an ordered one. Consistent with these phenomena and bringing more physical insight, the simplified model implies that the tuned vibration frequency and amplitude will lock in the unsteady flow separation, promote momentum transfer from the main stream to the separation zone, and make the flow field more orderly and less chaotic, resulting in a reduction of flow loss.


Micromachines ◽  
2018 ◽  
Vol 9 (8) ◽  
pp. 387
Author(s):  
Carlos Toshiyuki Matsumi ◽  
Wilson José da Silva ◽  
Fábio Kurt Schneider ◽  
Joaquim Miguel Maia ◽  
Rigoberto E. M. Morales ◽  
...  

Microbubbles have various applications including their use as carrier agents for localized delivery of genes and drugs and in medical diagnostic imagery. Various techniques are used for the production of monodisperse microbubbles including the Gyratory, the coaxial electro-hydrodynamic atomization (CEHDA), the sonication methods, and the use of microfluidic devices. Some of these techniques require safety procedures during the application of intense electric fields (e.g., CEHDA) or soft lithography equipment for the production of microfluidic devices. This study presents a hybrid manufacturing process using micropipettes and 3D printing for the construction of a T-Junction microfluidic device resulting in simple and low cost generation of monodisperse microbubbles. In this work, microbubbles with an average size of 16.6 to 57.7 μm and a polydispersity index (PDI) between 0.47% and 1.06% were generated. When the device is used at higher bubble production rate, the average diameter was 42.8 μm with increased PDI of 3.13%. In addition, a second-order polynomial characteristic curve useful to estimate micropipette internal diameter necessary to generate a desired microbubble size is presented and a linear relationship between the ratio of gaseous and liquid phases flows and the ratio of microbubble and micropipette diameters (i.e., Qg/Ql and Db/Dp) was found.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
C. Ahamed Saleel ◽  
Saad Ayed Alshahrani ◽  
Asif Afzal ◽  
Maughal Ahmed Ali Baig ◽  
Sarfaraz Kamangar ◽  
...  

PurposeJoule heating effect is a pervasive phenomenon in electro-osmotic flow because of the applied electric field and fluid electrical resistivity across the microchannels. Its effect in electro-osmotic flow field is an important mechanism to control the flow inside the microchannels and it includes numerous applications.Design/methodology/approachThis research article details the numerical investigation on alterations in the profile of stream wise velocity of simple Couette-electroosmotic flow and pressure driven electro-osmotic Couette flow by the dynamic viscosity variations happened due to the Joule heating effect throughout the dielectric fluid usually observed in various microfluidic devices.FindingsThe advantages of the Joule heating effect are not only to control the velocity in microchannels but also to act as an active method to enhance the mixing efficiency. The results of numerical investigations reveal that the thermal field due to Joule heating effect causes considerable variation of dynamic viscosity across the microchannel to initiate a shear flow when EDL (Electrical Double Layer) thickness is increased and is being varied across the channel.Originality/valueThis research work suggest how joule heating can be used as en effective mechanism for flow control in microfluidic devices.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7493
Author(s):  
Krystian L. Wlodarczyk ◽  
William N. MacPherson ◽  
Duncan P. Hand ◽  
M. Mercedes Maroto-Valer

In situ measurements are highly desirable in many microfluidic applications because they enable real-time, local monitoring of physical and chemical parameters, providing valuable insight into microscopic events and processes that occur in microfluidic devices. Unfortunately, the manufacturing of microfluidic devices with integrated sensors can be time-consuming, expensive, and “know-how” demanding. In this article, we describe an easy-to-implement method developed to integrate various “off-the-shelf” fiber optic sensors within microfluidic devices. To demonstrate this, we used commercial pH and pressure sensors (“pH SensorPlugs” and “FOP-MIV”, respectively), which were “reversibly” attached to a glass microfluidic device using custom 3D-printed connectors. The microfluidic device, which serves here as a demonstrator, incorporates a uniform porous structure and was manufactured using a picosecond pulsed laser. The sensors were attached to the inlet and outlet channels of the microfluidic pattern to perform simple experiments, the aim of which was to evaluate the performance of both the connectors and the sensors in a practical microfluidic environment. The bespoke connectors ensured robust and watertight connection, allowing the sensors to be safely disconnected if necessary, without damaging the microfluidic device. The pH SensorPlugs were tested with a pH 7.01 buffer solution. They measured the correct pH values with an accuracy of ±0.05 pH once sufficient contact between the injected fluid and the measuring element (optode) was established. In turn, the FOP-MIV sensors were used to measure local pressure in the inlet and outlet channels during injection and the steady flow of deionized water at different rates. These sensors were calibrated up to 140 mbar and provided pressure measurements with an uncertainty that was less than ±1.5 mbar. Readouts at a rate of 4 Hz allowed us to observe dynamic pressure changes in the device during the displacement of air by water. In the case of steady flow of water, the pressure difference between the two measuring points increased linearly with increasing flow rate, complying with Darcy’s law for incompressible fluids. These data can be used to determine the permeability of the porous structure within the device.


1971 ◽  
Vol 93 (3) ◽  
pp. 200-205
Author(s):  
Seth R. Goldstein ◽  
Andrew C. Harvey

Two passive gas flow controllers are presented which provide compensation for variations in ambient temperature and supply pressure. One technique, which provides first-order error compensation, utilizes a choked orifice having its area linearily varied in proportion to a diaphragm deflection. Compensation is achieved by applying upstream pressure to one side of the diaphragm, and by applying a trapped gas pressure proportional to absolute temperature on the other side of the diaphragm. General design relationships are presented, and a prototype unit constructed to control a minute flow rate of high-pressure oxygen is described. A second flow control technique is presented which provides the required nonlinear temperature compensation for flow supplied through a constant-area choked orifice. This is achieved by utilizing a compliant volume of trapped gas to generate a pressure proportional to the square root of absolute temperature. This pressure is used to control the pressure upstream of the choked orifice, thus providing constant flow.


Author(s):  
Ahmed Fadl ◽  
Stefanie Demming ◽  
Zongqin Zhang ◽  
Bjo¨rn Hoxhold ◽  
Stephanus Bu¨ttgenbach ◽  
...  

Developing multifunctional devices are essential to realize more efficient Microsystems. With miniaturization processes taking place in many different applications, the rooms for single function microfluidic devices are limited. In this study, we introduce a multifunctional micro fluidic device based on bifurcation geometry which is capable of performing pumping and mixing at the same time. Optical lithography is used to fabricate the designed microfluidic device. The microfluidic device is tested at low actuator frequencies, and ethanol is employed as a working fluid. The operational principles are based on rectifying the oscillatory flows by using bifurcation structures for flow rectification. The results prove the feasibility of the novel design, and results are presented in terms of flow rates and maximum back pressures.