scholarly journals Determination of substrate composition, light, and temperature for interior plant growth

2021 ◽  
Vol 284 ◽  
pp. 03015
Author(s):  
Shahzod Egamberdiev ◽  
Mansurbek Kholmurotov ◽  
Erkin Berdiev ◽  
Temurmalik Ochilov ◽  
Rustam Oymatov ◽  
...  

This article presents the experimental results for determining the composition of the substrate, light and temperature for growing houseplants. Substrates were prepared in 8 different variants. The properties of the substrates were evaluated on the basis of 3 types: high, medium, and low. The amount of light required for the growth of houseplants is the result of a seasonal study. The effects of daily light fall and outdoor ambient temperature in the interior environment was studied for one year, and the results obtained were tabulated. According to the attitude of plants to light, they were divided into light-loving, semi-shade, shade-loving species.

1970 ◽  
Vol 11 (1) ◽  
Author(s):  
A. Bista ◽  
G. B. Khattri ◽  
B. D. Acharya ◽  
S. C. Srivastava

To find out the ability of Orobanche seeds to germinate immediately after seed set, seeds were germinated periodically at an interval of three months for one year in GR24. Some Orobanche seeds were capable of germination immediately after seed set but most required about nine months as after ripening or incubation period to be able to germinate. The phenomenon of after ripening in Orobanche seeds could be taken as an ecological measure to dormant over following unfavorable wet summer season. The growth hormone studies on Orobanche seed germination have shown that GA3 at a concentration of 100 ppm substantially enhanced seed germination when applied during pre-conditioning period. NAA showed some stimulatory effect at 0.5 - 1.0 ppm when applied during post-conditioning period but the hormone if applied during pre-conditioning period inhibited the germination. Kinetin failed to stimulate the germination at all the concentrations tested. Key words: Germination, root-parasite, hormone. Ecoprint Vol.11(1) 2004.


1999 ◽  
Vol 64 (11) ◽  
pp. 1770-1779 ◽  
Author(s):  
Herbert Mayr ◽  
Karl-Heinz Müller

The kinetics of the electrophilic additions of four diarylcarbenium ions (4a-4d) to tricarbonyl(η4-cyclohepta-1,3,5-triene)iron (1) have been studied photometrically. The second-order rate constants match the linear Gibbs energy relationship log k20 °C = s(E + N) and yield the nucleophilicity parameter N(1) = 3.69. It is concluded that electrophiles with E ≥ -9 will react with complex 1 at ambient temperature.


2020 ◽  
Vol 835 ◽  
pp. 229-242
Author(s):  
Oboso P. Bernard ◽  
Nagih M. Shaalan ◽  
Mohab Hossam ◽  
Mohsen A. Hassan

Accurate determination of piezoelectric properties such as piezoelectric charge coefficients (d33) is an essential step in the design process of sensors and actuators using piezoelectric effect. In this study, a cost-effective and accurate method based on dynamic loading technique was proposed to determine the piezoelectric charge coefficient d33. Finite element analysis (FEA) model was developed in order to estimate d33 and validate the obtained values with experimental results. The experiment was conducted on a piezoelectric disc with a known d33 value. The effect of measuring boundary conditions, substrate material properties and specimen geometry on measured d33 value were conducted. The experimental results reveal that the determined d33 coefficient by this technique is accurate as it falls within the manufactures tolerance specifications of PZT-5A piezoelectric film d33. Further, obtained simulation results on fibre reinforced and particle reinforced piezoelectric composite were found to be similar to those that have been obtained using more advanced techniques. FE-results showed that the measured d33 coefficients depend on measuring boundary condition, piezoelectric film thickness, and substrate material properties. This method was proved to be suitable for determination of d33 coefficient effectively for piezoelectric samples of any arbitrary geometry without compromising on the accuracy of measured d33.


Sign in / Sign up

Export Citation Format

Share Document