scholarly journals Numerical investigation on the cooling performance of a novel jet cooler design for a supercritical CO2 turbine rotor shaft cooling

2021 ◽  
Vol 22 ◽  
pp. 51
Author(s):  
Jun Li ◽  
Hal Gurgenci ◽  
Jishun Li ◽  
Zhiqiang Guan ◽  
Lun Li ◽  
...  

Numerical investigation was carried out to study the heat transfer performance for a high-speed rotating cylindrical surface subjected to single row array round jets impingement, under a very small gap spacing. Various parameters that affect heat transfer, such as the fluid density, flow velocity and Nusselt number distributions of the radius clearance were studied based on varied nozzle to target surface spacing H and mass flow rate. It has been found that the fluid density was a dominant factor and the velocity was the secondary factor for the gas jet heat transfer performances. The overall heat transfer was improved with a reduction in the number of nozzles, for given inlet mass flow rate boundary conditions. The decrease of H/di (di, nozzle diameter) may have positive or negative effects on the heat transfer performance from the impingement surface. Reducing the radius gap H, for a certainty, increases the average density of the fluid in the clearance, which is desirable in applications that enhance heat transfer performance. But when the radius gap (H) is small enough, increasing di may have a negative impact on heat transfer.

2019 ◽  
Vol 256 ◽  
pp. 03001
Author(s):  
Zhou Ying ◽  
He Chao ◽  
Bing Bai ◽  
Juan Ning

Extensive numerical study on the heat transfer performance of the gaseous nitrogen (GN) thermoregulation shroud surface was conducted in this work. The average heat transfer coefficient was investigated under different shroud length and nitrogen parameters (such as velocity, temperature and mass flow rate). The result shows that the heat transfer performance is affected less by shroud length but largely by mass flow rate. When the mass flow rate is constant, the inlet temperature increases heat transfer coefficient. Finally, dimensionless correlation of the average Nusselt number over shroud surface with Reynolds number and Prandtl number was obtained.


Energies ◽  
2019 ◽  
Vol 12 (11) ◽  
pp. 2085 ◽  
Author(s):  
Zhongchao Zhao ◽  
Yimeng Zhou ◽  
Xiaolong Ma ◽  
Xudong Chen ◽  
Shilin Li ◽  
...  

The channels of a printed circuit heat exchanger (PCHE) can have different shapes, and the zigzag channel shape is one of the most widely used because of the relatively simple manufacturing process and low cost. However, the heat transfer enhancement of a zigzag channel is at the expense of increasing the pressure drop. In this paper, new channel shapes of a PCHE, i.e., a zigzag with an inserted straight channel and a zigzag channel with radian, were numerically investigated, with the aim of improving the heat transfer and reducing the pressure drop of supercritical LNG using the SST κ-ω model. The local and total pressure drop and heat transfer performance of supercritical LNG in a zigzag channel, zigzags with 1–5 mm inserted straight channels, and a zigzag channel with radian were analyzed by varying the mass flow rate from 1.83 × 10−4 to 5.49 × 10−4 kg/s. Performance evaluation criteria (PEC) were applied to compare the overall heat transfer performance of the zigzags with 1–5 mm inserted straight channels and a zigzag channel with radian to the zigzag channel of a PCHE. The maximum pressure drop for the zigzag channel was twice the minimum pressure drop for the zigzag channel with radian, while the convective heat transfer coefficient of the zigzag with a 4 mm inserted straight channel was higher, which was 1.2 times that of the zigzag channel with radian with the smallest convective heat transfer coefficient. The maximum value of the PEC with 1.099 occurred at a mass flow rate of 1.83 × 10−4 kg/s for the zigzag with a 4 mm inserted straight channel, while the minimum value of the PEC with 1.021 occurred at a mass flow rate of 5.49 × 10−4 kg/s for the zigzag with a 1 mm inserted straight channel. The zigzag with a 4 mm inserted straight channel had the best performance, as it had a higher PEC value at lower mass flow rates.


Author(s):  
Geng Xu ◽  
Hua Chen ◽  
Songtian Zhao ◽  
Shusong Ren ◽  
Wei Zhao

Background: The flow rate distribution in the flat tubes of a micro-channel evaporator is essential for its heat transfer performance. Due to a large number of flat tubes in a micro-channel evaporator, the flow rate distribution is often difficult to determine. Objective: An evaporator test rig was constructed to study the quantification of the refrigerant mass flow rate distribution in a two-pass evaporator without de-stroying its structure. Methods: A heat transfer performance test rig for a two-pass evaporator was es-tablished. Subcooled refrigerant R134a was pumped into the inlet header, and infrared thermography was used to obtain the cloud map of the wall tempera-ture distribution on the surface of the evaporator. The flow rate distribution in each flat tube was calculated based on an analysis that combines the heat bal-ance between the airside and the refrigerant side with the effectiveness-Number of Transfer Units (ε-NTU) method. Results: The flow rate distribution was found to be in good agreement with the evaporator wall temperature distribution. The difference between the calculated and measured total mass flow rates was less than 15.9%, which proves that the method is simple and effective. The unevenness of flowrate distribution in the 1st and 2nd pass is 0.13 and 0.32, respectively. Conclusion: This method is simple and effective and does not destroy the structure of the micro-channel evaporator. However, it is only suitable for cases in which subcooled zone exists in a pass and is not applicable to a pass in which the refrigerant is only in a single-phase or a two-phase state.


Author(s):  
Gaowen Liu ◽  
Zhao Lei ◽  
Aqiang Lin ◽  
Qing Feng ◽  
Yan Chen

The pre-swirl system is of great importance for temperature drop and cooling air supply. This study aims to investigate the influencing mechanism of heat transfer, nonuniform thermodynamic characteristics, and cooling air supply sensitivity in a pre-swirl system by the application of the flow control method of the pre-swirl nozzle. A novel test rig was proposed to actively control the supplied cooling air mass flow rate by three adjustable pre-swirl nozzles. Then, the transient problem of the pre-swirl system was numerically conducted by comparison with 60°, 120°, and 180° rotating disk cavity cases, which were verified with the experiment results. Results show that the partial nozzle closure will aggravate the fluctuation of air supply mass flow rate and temperature. When three parts of nozzles are closed evenly at 120° in the circumferential direction, the maximum value of the nonuniformity coefficient of air supply mass flow rate changes to 3.1% and that of temperature changes to 0.25%. When six parts of nozzles are closed evenly at 60° in the circumferential direction, the maximum nonuniformity coefficient of air supply mass flow rate changes to 1.4% and that of temperature changes to 0.20%. However, different partial nozzle closure modes have little effect on the average air supply parameters. Closing 14.3% of the nozzle area will reduce the air supply mass flow rate by 9.9% and the average air supply temperature by about 1 K.


Author(s):  
Liang-Han Chien ◽  
S.-Y. Pei ◽  
T.-Y. Wu

This study investigates the influence of the heat flux and mass velocity on convective heat transfer performance of FC-72 in a rectangular channel of 20mm in width and 2 mm in height. The heated side has either a smooth surface or a pin-finned surface. The inlet fluid temperature is maintained at 30°C. The total length of the test channel is 113 mm, with a heated length of 25mm. The flow rate varies between 80 and 960 ml/min, and the heat flux sets between 18 and 50 W/cm2. The experimental results show that the controlling variable is heat flux instead of flow rate because of the boiling activities in FC-72. At a fixed flow rate, the pin-finned surface yields up to 20% higher heat transfer coefficient and greater critical heat flux than those of a smooth surface.


2003 ◽  
Vol 125 (1) ◽  
pp. 104-113 ◽  
Author(s):  
Chang-Yuan Liu ◽  
Ying-Huei Hung

Both experimental and theoretical investigations on the heat transfer and flow friction characteristics of compact cold plates have been performed. From the results, the local and average temperature rises on the cold plate surface increase with increasing chip heat flux or decreasing air mass flow rate. Besides, the effect of chip heat flux on the thermal resistance of cold plate is insignificant; while the thermal resistance of cold plate decreases with increasing air mass flow rate. Three empirical correlations of thermal resistance in terms of air mass flow rate with a power of −0.228 are presented. As for average Nusselt number, the effect of chip heat flux on the average Nusselt number is insignificant; while the average Nusselt number of the cold plate increases with increasing Reynolds number. An empirical relationship between Nu¯cp and Re can be correlated. In the flow frictional aspect, the overall pressure drop of the cold plate increases with increasing air mass flow rate; while it is insignificantly affected by chip heat flux. An empirical correlation of the overall pressure drop in terms of air mass flow rate with a power of 1.265 is presented. Finally, both heat transfer performance factor “j” and pumping power factor “f” decrease with increasing Reynolds number in a power of 0.805; while they are independent of chip heat flux. The Colburn analogy can be adequately employed in the study.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.