The Effect of Aberrant Rotation on Radiographic Patellar Height Measurement Using Canton-Deschamps Index: A Cadaveric Analysis

Author(s):  
Hailey P. Huddleston ◽  
Michael L. Redondo ◽  
William M. Cregar ◽  
David R. Christian ◽  
Charles P. Hannon ◽  
...  

AbstractThe Caton-Deschamps Index (CDI) is a measurement used to evaluate patella alta based on true lateral radiographs; however, no prior study has investigated how altering the degree of radiograph aberrancy affects CDI measurement. The primary and secondary purpose of this study was to evaluate effects of rotational radiographic changes on patella height measurements and compare these findings to MRI measurements, respectively. Five cadaver knees (n = 5) were utilized in this study. True lateral radiographs were obtained for each specimen by using a fluoroscopic C-arm machine. The C-arm was then altered in two planes (axial and coronal) in both the clockwise and counterclockwise direction and radiographs were taken at 5, 10, and 15 degrees of error from the true lateral position. A CDI measurement of each specimen was performed based on sagittal magnetic resonance imaging (MRI) slices and compared with radiographic CDI measurements. Three orthopedic surgeons measured the CDI for each radiograph and MRI performed. Interrater reliability and changes in CDI were analyzed. Clinically significant difference in CDI was set to 0.1. Mean intraclass correlation coefficient was high (≥0.7) at true lateral and at all varying degrees of error. When performing a pairwise comparison of mean CDI from the true lateral position to increasing degrees of error, statistically significant differences were observed in the axial plane. The largest change in CDI measurements was seen with rotational malposition in the axial plane and counterclockwise direction. No statistically significant differences in mean CDI were observed in the coronal plane. The change in CDI from the true lateral position reached an absolute maximum of at least 0.1 in all four scenarios at each tested degree of error. This study found that aberrant radiographic rotation in the axial plane resulted in a significantly different mean CDI measurement when compared with true lateral radiographs. All degrees of error in both directions and in both planes could have a clinically significant effect on CDI (≥0.1). Our findings confirm the importance of a perfect true lateral radiograph when measuring patella height.

1989 ◽  
Vol 20 (2) ◽  
pp. 149-152 ◽  
Author(s):  
Kenneth W. Berger

Hearing aid gain usage by two groups of children was examined. No appreciable difference was noted between the groups, nor was there a clinically significant difference between gain usage by these children as compared with a sample of adult hearing aid wearers.


Author(s):  
Anders Batman Mjelle ◽  
Anesa Mulabecirovic ◽  
Roald Flesland Havre ◽  
Edda Jonina Olafsdottir ◽  
Odd Helge Gilja ◽  
...  

Abstract Purpose Liver elastography is increasingly being applied in screening for and follow-up of pediatric liver disease, and has been shown to correlate well with fibrosis staging through liver biopsy. Because time is of the essence when examining children, we wanted to evaluate if a reliable result can be achieved with fewer acquisitions. Materials and Methods 243 healthy children aged 4–17 years were examined after three hours of fasting. Participants were divided into four age groups: 4–7 years; 8–11 years; 12–14 years and 15–17 years. Both two-dimensional shear wave elastography (2D-SWE; GE Logiq E9) and point shear wave elastography (pSWE; Samsung RS80A with Prestige) were performed in all participants, while transient elastography (TE, Fibroscan) was performed in a subset of 87 children aged 8–17 years. Median liver stiffness measurement (LSM) values of 3, 4, 5, 6, 7, and 8 acquisitions were compared with the median value of 10 acquisitions (reference standard). Comparison was performed for all participants together as well as within every specific age group. We investigated both the intraclass correlation coefficient (ICC) with absolute agreement and all outliers more than 10 %, 20 % or ≥ 0.5 or 1.0 kPa from the median of 10 acquisitions. Results For all three systems there was no significant difference between three and ten acquisitions, with ICCs ≥ 0.97. All systems needed 4 acquisitions to achieve no LSM deviating ≥ 1.0 kPa of a median of ten. To achieve no LSM deviating ≥ 20 % of a median of ten acquisitions, pSWE and TE needed 4 acquisitions, while 2D-SWE required 6 acquisitions. Conclusion Our results contradict recommendations of 10 acquisitions for pSWE and TE and only 3 for 2D-SWE.


Animals ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1979
Author(s):  
Jurhamid Columbres Imlan ◽  
Ubedullah Kaka ◽  
Yong-Meng Goh ◽  
Zulkifli Idrus ◽  
Elmutaz Atta Awad ◽  
...  

The proper slaughter positioning of animals is among the most crucial factors in animal welfare. The lateral position in Halal slaughter is a technique used around the world by Muslims, with a few practicing the upright position. The literature on the effects of slaughter in upright versus lateral positions on pain and stress is scarce. Thus, this study was designed to evaluate the effects of slaughter positions on blood biochemical parameters, plasma catecholamines, and electroencephalographic (EEG) responses. Twenty Brahman crossbred steers were subjected to slaughter in either lateral recumbency (LP) (n = 10) or an upright position (UP) (n = 10). There was a significant increase in adrenaline (p < 0.0001) and noradrenaline (p < 0.05) at T2 compared to T1 in the animals of both groups. A significant difference (p < 0.0001) was observed in the median frequency (MF) and total power (Ptot) of EEG, parameters for pain and stress, between the animals slaughtered in the upright and the lateral position. However, MF and delta waves were significantly higher (p < 0.05) after slaughter in the UP group than in the LP group. The results demonstrate a lesser amount of stress and pain responses among the LP group.


2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S163-S164
Author(s):  
K G Manjee ◽  
W G Watkin

Abstract Introduction/Objective Cervical biopsy is performed following an abnormal pap smear or positive HPV testing in an attempt to uncover clinically significant lesions [HSIL/invasive carcinoma (HSIL+)]. An excisional procedure is considered if biopsy confirms HSIL+. When preceded by pap smear of LSIL, ASCUS, NILM/HPV+ or persistent HPV, continued surveillance is recommended for biopsies showing no SIL or LSIL. In our laboratory, cervical biopsies are routinely sectioned at 3 levels. Deeper levels are often ordered when initial sections are non-diagnostic. p16 immunohistochemistry, with or without deeper levels, is often ordered to confirm HSIL, or to differentiate HSIL from mimics. In this study, we examine whether and in what clinical situations does obtaining additional levels uncover clinically significant lesions. Methods 430 cervical biopsies between January-May 2018, with recent cytology of LSIL, ASCUS or NILM/HPV+ were identified in the pathology database. HPV status (if known), final biopsy diagnosis and past history of LSIL/HSIL were recorded. For each biopsy, orders for additional levels and/or p16 immunohistochemistry were recorded resulting in 4 categories: C1-no additional levels or p16, C2-deeper only, C3-deeper+p16 and C4-p16 only. Final diagnoses were divided into HSIL+, LSIL and no SIL. Results There was no significant difference in prior history of LSIL/HSIL and HPV status between all categories. Biopsy results were as follows: HSIL+: 11/222 (5%) C1; 1/78 (1%) C2; 7/43 (16%) C3; 15/87 (17%) C4 LSIL: 91/222 (41%) C1; 7/78 (9%) C2; 16/43 (37%) C3; 35/87 (40%) C4 No SIL: 120/222 (54%) C1; 70/78 (90%) C2; 20/43 (46%) C3; 37/87 (42%) C4 The average number of additional levels in C2 and C3 was 3.8 and 1.8, respectively. Conclusion Deeper levels alone did not enhance the detection of HSIL+. Almost all LSIL/HSIL were detected when initial levels were diagnostic or suspicious and supported by p16 immunohistochemistry. 3 levels are adequate to detect clinically significant lesions.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Kempny ◽  
K Dimopoulos ◽  
A E Fraisse ◽  
G P Diller ◽  
L C Price ◽  
...  

Abstract Background Pulmonary vascular resistance (PVR) is an essential parameter assessed during cardiac catheterization. It is used to confirm pulmonary vascular disease, to assess response to targeted pulmonary hypertension (PH) therapy and to determine the possibility of surgery, such as closure of intra-cardiac shunt or transplantation. While PVR is believed to mainly reflect the properties of the pulmonary vasculature, it is also related to blood viscosity (BV). Objectives We aimed to assess the relationship between measured (mPVR) and viscosity-corrected PVR (cPVR) and its impact on clinical decision-making. Methods We assessed consecutive PH patients undergoing cardiac catheterization. BV was assessed using the Hutton method. Results We included 465 patients (56.6% female, median age 63y). The difference between mPVR and cPVR was highest in patients with abnormal Hb levels (anemic patients: 5.6 [3.4–8.0] vs 7.8Wood Units (WU) [5.1–11.9], P<0.001; patients with raised Hb: 10.8 [6.9–15.4] vs. 7.6WU [4.6–10.8], P<0.001, respectively). Overall, 33.3% patients had a clinically significant (>2.0WU) difference between mPVR and cPVR, and this was more pronounced in those with anemia (52.9%) or raised Hb (77.6%). In patients in the upper quartile for this difference, mPVR and cPVR differed by 4.0WU [3.4–5.2]. Adjustment of PVR required Conclusions We report, herewith, a clinically significant difference between mPVR and cPVR in a third of contemporary patients assessed for PH. This difference is most pronounced in patients with anemia, in whom mPVR significantly underestimates PVR, whereas in most patients with raised Hb, mPVR overestimates it. Our data suggest that routine adjustment for BV is necessary.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1328
Author(s):  
Jorge Martin-Gutierrez ◽  
Marta Sylvia Del Rio Guerra

There has been a conscious shift towards developing increasingly inclusive applications. However, despite this fact, most research has focused on supporting those with visual or hearing impairments and less attention has been paid to cognitive impairments. The purpose of this study is to analyse touch gestures used for touchscreens and identify which gestures are suitable for individuals living with Down syndrome (DS) or other forms of physical or cognitive impairments. With this information, app developers can satisfy Design for All (DfA) requirements by selecting adequate gestures from existing lists of gesture sets. Twenty touch gestures were defined for this study and a sample group containing eighteen individuals with Down syndrome was used. A tool was developed to measure the performance of touch gestures and participants were asked to perform simple tasks that involved the repeated use of these twenty gestures. Three variables are analysed to establish whether they influence the success rates or completion times of gestures, as they could have a collateral effect on the skill with which gestures are performed. These variables are Gender, Type of Down syndrome, and Socioeconomic Status. Analysis reveals that significant difference is present when a pairwise comparison is performed, meaning individuals with DS cannot perform all gestures with the same ease. The variables Gender and Socioeconomic Status do not influence success rates or completion times, but Type of DS does.


2021 ◽  
pp. 1-8
Author(s):  
Yasemin Eskigülek ◽  
Sultan Kav

Abstract Objective The aim of this study was to investigate the validity and reliability of the Patient Dignity Inventory (PDI) in the Turkish society, which was developed to evaluate dignity-related distress in palliative care patients. Methods One hundred and twenty-seven adults with advanced cancer hospitalized in several clinics of two university hospitals were included in the study. The patients whose Palliative Performance Scale score was at least 40% were recruited to study. The data were collected with a patient demographic form, the Turkish version of Hospital Anxiety and Depression Scale (HADS-TR), and the Turkish version of the PDI (PDI-TR). The PDI-TR was finalized and back-translated after translating into Turkish and obtaining 10 expert opinions. Exploratory and confirmatory factor analysis, internal consistency, concurrent validity, and test–retest reliability analysis were performed. Results The Cronbach's α coefficient of PDI-TR was 0.94. Factor analysis resulted in a five-factor solution, and all items were loaded on factors. Factors were labeled as symptom distress, existential distress, self-confidence, dependency, and supportive care needs and accounted for 68.70% of the overall variance. The model's normed fit index, comparative fit index, and X2/SD were found between acceptable range (0.90, 0.93, and 2.64, respectively). A positive and strong correlation was found between subdimension scores of HADS-TR and the total score of PDI-TR (r = 0.70 for anxiety subdimension; r = 0.73 for depression subdimension). The test–retest reliability was conducted with 32 patients within the sample two weeks after the first application, and no significant difference was found between the two application scores as the result of paired-sample t-test (p > 0.05). An intraclass correlation coefficient of test–retest reliability was r = 0.855. Significance of results PDI-TR was found to be a valid and reliable tool in palliative care patients in Turkish society.


2020 ◽  
Vol 57 (6) ◽  
pp. 341-347
Author(s):  
Jaeyeon Chung ◽  
Sang-Hwan Ji ◽  
Young-Eun Jang ◽  
Eun-Hee Kim ◽  
Ji-Hyun Lee ◽  
...  

Near-infrared spectroscopy devices can measure peripheral tissue oxygen saturation (StO<sub>2</sub>). This study aims to compare StO<sub>2</sub> using INVOS® and different O3™ settings (O3<sup>25:75</sup> and O3<sup>30:70</sup>). Twenty adults were recruited. INVOS® and O3™ probes were placed simultaneously on 1 side of forearm. After baseline measurement, the vascular occlusion test was initiated. The baseline value, rate of deoxygenation and reoxygenation, minimum and peak StO<sub>2</sub>, and time from cuff release to peak value were measured. The parameters were compared using ANOVA and Kruskal-Wallis tests. Bonferroni’s correction and Mann-Whitney pairwise comparison were used for post hoc analysis. The agreement between StO<sub>2</sub> of devices was evaluated using Bland-Altman plots. INVOS® baseline value was higher (79.7 ± 6.4%) than that of O3<sup>25:75</sup> and O3<sup>30:70</sup> (62.4 ± 6.0% and 63.7 ± 5.5%, respectively, <i>p</i> &#x3c; 0.001). The deoxygenation rate was higher with INVOS® (10.6 ± 2.1%/min) than with O3<sup>25:75</sup> and O3<sup>30:70</sup> (8.4 ± 2.2%/min, <i>p</i> = 0.006 and 7.5 ± 2.1%/min, <i>p</i> &#x3c; 0.001). The minimum and peak StO<sub>2</sub> were higher with INVOS®. No significant difference in the reoxygenation rate was found between the devices and settings. The time to reach peak after cuff deflation was faster with INVOS® (both <i>p</i> &#x3c; 0.001). Other parameters were similar. There were no differences between the different O3™ settings. There were differences in StO<sub>2</sub> measurements between the devices, and these devices should not be interchanged. Differences were not observed between O3™ device settings.


2016 ◽  
Vol 96 (5) ◽  
pp. 687-695 ◽  
Author(s):  
Andreanne K. Blanchette ◽  
Aditi A. Mullick ◽  
Karina Moïn-Darbari ◽  
Mindy F. Levin

Background Commonly used spasticity scales assess the resistance felt by the evaluator during passive stretching. These scales, however, have questionable validity and reliability. The tonic stretch reflex threshold (TSRT), or the angle at which motoneuronal recruitment begins in the resting state, is a promising alternative for spasticity measurement. Previous studies showed that spasticity and voluntary motor deficits after stroke may be characterized by a limitation in the ability of the central nervous system to regulate the range of the TSRT. Objective The study objective was to assess interevaluator reliability for TSRT plantar-flexor spasticity measurement. Design This was an interevaluator reliability study. Methods In 28 people after stroke, plantar-flexor spasticity was evaluated twice on the same day. Plantar-flexor muscles were stretched 20 times at different velocities assigned by a portable device. Plantar-flexor electromyographic signals and ankle angles were used to determine dynamic velocity-dependent thresholds. The TSRT was computed by extrapolating a regression line through dynamic velocity-dependent thresholds to the angular axis. Results Mean TSRTs in evaluations 1 and 2 were 66.0 degrees (SD=13.1°) and 65.8 degrees (SD=14.1°), respectively, with no significant difference between them. The intraclass correlation coefficient (2,1) was .851 (95% confidence interval=.703, .928). Limitations The notion of dynamic stretch reflex threshold does not exclude the possibility that spasticity is dependent on acceleration, as well as on velocity; future work will study both possibilities. Conclusions Tonic stretch reflex threshold interevaluator reliability for evaluating stroke-related plantar-flexor spasticity was very good. The TSRT is a reliable measure of spasticity. More information may be gained by combining the TSRT measurement with a measure of velocity-dependent resistance.


Sign in / Sign up

Export Citation Format

Share Document