scholarly journals Thermal Relaxation of Very Small Solar Magnetic Structures in Intergranules: A Process That Produces Kilogauss Magnetic Field Strengths

2001 ◽  
Vol 556 (2) ◽  
pp. 928-936 ◽  
Author(s):  
J. Sanchez Almeida
1967 ◽  
Vol 31 ◽  
pp. 381-383
Author(s):  
J. M. Greenberg

Van de Hulst (Paper 64, Table 1) has marked optical polarization as a questionable or marginal source of information concerning magnetic field strengths. Rather than arguing about this–I should rate this method asq+-, or quarrelling about the term ‘model-sensitive results’, I wish to stress the historical point that as recently as two years ago there were still some who questioned that optical polarization was definitely due to magnetically-oriented interstellar particles.


Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1459
Author(s):  
Tatiana N. Zamay ◽  
Vladimir S. Prokopenko ◽  
Sergey S. Zamay ◽  
Kirill A. Lukyanenko ◽  
Olga S. Kolovskaya ◽  
...  

Magnetomechanical therapy is one of the most perspective directions in tumor microsurgery. According to the analysis of recent publications, it can be concluded that a nanoscalpel could become an instrument sufficient for cancer microsurgery. It should possess the following properties: (1) nano- or microsized; (2) affinity and specificity to the targets on tumor cells; (3) remote control. This nano- or microscalpel should include at least two components: (1) a physical nanostructure (particle, disc, plates) with the ability to transform the magnetic moment to mechanical torque; (2) a ligand—a molecule (antibody, aptamer, etc.) allowing the scalpel precisely target tumor cells. Literature analysis revealed that the most suitable nanoscalpel structures are anisotropic, magnetic micro- or nanodiscs with high-saturation magnetization and the absence of remanence, facilitating scalpel remote control via the magnetic field. Additionally, anisotropy enhances the transmigration of the discs to the tumor. To date, four types of magnetic microdiscs have been used for tumor destruction: synthetic antiferromagnetic P-SAF (perpendicular) and SAF (in-plane), vortex Py, and three-layer non-magnetic–ferromagnet–non-magnetic systems with flat quasi-dipole magnetic structures. In the current review, we discuss the biological effects of magnetic discs, the mechanisms of action, and the toxicity in alternating or rotating magnetic fields in vitro and in vivo. Based on the experimental data presented in the literature, we conclude that the targeted and remotely controlled magnetic field nanoscalpel is an effective and safe instrument for cancer therapy or theranostics.


Author(s):  
Jean-Francois Lestrade ◽  
Robert L. Mutel ◽  
Robert A. Preston ◽  
Robert B. Phillips

2014 ◽  
Vol 1 (1) ◽  
Author(s):  
G. Tosolini ◽  
J. M. Michalik ◽  
R. Córdoba ◽  
J. M. de Teresa ◽  
F. Pérez-Murano ◽  
...  

AbstractWe present the magnetic characterization of cobalt wires grown by focused electron beam-induced deposition (FEBID) and studied using static piezoresistive cantilever magnetometry. We have used previously developed high force sensitive submicron-thick silicon piezoresistive cantilevers. High quality polycrystalline cobalt microwires have been grown by FEBID onto the free end of the cantilevers using dual beam equipment. In the presence of an external magnetic field, the magnetic cobalt wires become magnetized, which leads to the magnetic field dependent static deflection of the cantilevers. We show that the piezoresistive signal from the cantilevers, corresponding to a maximum force of about 1 nN, can be measured as a function of the applied magnetic field with a good signal to noise ratio at room temperature. The results highlight the flexibility of the FEBID technique for the growth of magnetic structures on specific substrates, in this case piezoresistive cantilevers.


Author(s):  
K. Mendelssohn ◽  
J. D. Babbitt ◽  
Frederick Alexander Lindemann

Until a year ago it was generally accepted that if a body is made supraconducting while in a magnetic field the lines of magnetic force were "frozen in," i. e ., whatever lines of force passed through the body at the time when it became supraconducting remained there afterwards, unaffected by any change in the external field, so long as the body was supraconducting. Meissner and Ochsenfeld, however, showed that this supposition was not true. They measured field strengths in the immediate neighbourhood of cylinders which had been cooled to supraconductivity in an external magnetic field, and found that the field of force was then of the same nature as that to be expected in the neighbourhood of perfectly diamagnetic bodies. Thus it appeared that when a body becomes supraconducting in a magnetic field the lines of force are all pressed out of the body, and the induction inside the body falls to zero. At the same time, however, these authors report on another experiment, the result of which appears to us not entirely in accordance with the assumption that the induction in the whole body became zero. They measured the field strengths inside and outside a hollow cylinder, after it had become supraconducting in a field perpendicular to its axis, and found again that the field strength outside was as if the cylinder were almost perfectly diamagnetic, but the field inside was appreciably the same as if the cylinder were non-supraconducting. We therefore made a number of experiments, hoping to find out more exactly the nature of the phenomenon.


2018 ◽  
Vol 19 (2) ◽  
pp. 495 ◽  
Author(s):  
Irina Paun ◽  
Roxana Popescu ◽  
Bogdan Calin ◽  
Cosmin Mustaciosu ◽  
Maria Dinescu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document