scholarly journals Towards climate resilient residential buildings: learning from traditional typologies

2021 ◽  
Vol 2042 (1) ◽  
pp. 012146
Author(s):  
D Mohaibesh ◽  
S Monna ◽  
H Qadi ◽  
R Sokkar

Abstract Climate-resilient buildings in Palestine can play an important role in a more sustainable residential building sector. This paper aims at evaluating the effects of adopting architectural design strategies and material technologies from vernacular architecture to create a new climate-resilient building. The paper targets single houses as these represent the majority of residential buildings in suburban and rural areas, and are similar to the vernacular architecture in size and functionality. The EDSL Tas simulation tool was used to assess the thermal performance and energy savings in the proposed model compared with traditional houses and modern typical houses, in two different climatic zones. The proposed climate-resilient house has materials and design strategies derived from vernacular architecture, in addition to the use of thermal insulation. The results show that the proposed house is more climate-resilient compared to modern houses. In cold winter and hot summer climates, the proposed model presents a total annual heating and cooling energy consumption of 59% less than typical modern houses, and 5% more than old buildings. In hot arid summer and warm winter climates, the proposed house presents a total annual heating and cooling energy consumption of 58% less than a modern typical house and 8% more than the traditional house.

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3876
Author(s):  
Sameh Monna ◽  
Adel Juaidi ◽  
Ramez Abdallah ◽  
Aiman Albatayneh ◽  
Patrick Dutournie ◽  
...  

Since buildings are one of the major contributors to global warming, efforts should be intensified to make them more energy-efficient, particularly existing buildings. This research intends to analyze the energy savings from a suggested retrofitting program using energy simulation for typical existing residential buildings. For the assessment of the energy retrofitting program using computer simulation, the most commonly utilized residential building types were selected. The energy consumption of those selected residential buildings was assessed, and a baseline for evaluating energy retrofitting was established. Three levels of retrofitting programs were implemented. These levels were ordered by cost, with the first level being the least costly and the third level is the most expensive. The simulation models were created for two different types of buildings in three different climatic zones in Palestine. The findings suggest that water heating, space heating, space cooling, and electric lighting are the highest energy consumers in ordinary houses. Level one measures resulted in a 19–24 percent decrease in energy consumption due to reduced heating and cooling loads. The use of a combination of levels one and two resulted in a decrease of energy consumption for heating, cooling, and lighting by 50–57%. The use of the three levels resulted in a decrease of 71–80% in total energy usage for heating, cooling, lighting, water heating, and air conditioning.


Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

A humidity-sensitive demand-controlled ventilation system is known for many years. It has been developed and commonly applied in regions with an oceanic climate. Some attempts were made to introduce this solution in Poland in a much severe continental climate. The article evaluates this system's performance and energy consumption applied in an 8-floor multi-unit residential building, virtual reference building described by the National Energy Conservation Agency NAPE, Poland. The simulations using the computer program CONTAM were performed for the whole hating season for Warsaw's climate. Besides passive stack ventilation that worked as a reference, two versions of humidity-sensitive demand-controlled ventilation were checked. The difference between them lies in applying the additional roof fans that convert the system to hybrid. The study confirmed that the application of demand-controlled ventilation in multi-unit residential buildings in a continental climate with warm summer (Dfb) leads to significant energy savings. However, the efforts to ensure acceptable indoor air quality require hybrid ventilation, which reduces the energy benefits. It is especially visible when primary energy use is analyzed.


Author(s):  
Hua Chen ◽  
Qianqian Di

To improve the applicability of water-cooled air-conditioners in the domestic sector, the development of a prediction model for energy performance analysis is needed. This paper addressed the development of an empirical model for predicting the operation performance and the annual energy consumption for the use of water-cooled air-conditioners. An experimental prototype was set up and tested in an environmental chamber in validating the empirical model. The predictions compared well with the experimental results. Furthermore, a high-rise residential building whole-year energy consumption simulation on applications of water-cooled air conditioners in South china was also analyzed. The results show 20.4% energy savings over air-cooled units while the increase in water-side consumption is 31.1%. The overall energy savings were estimated at 16.2% when including the additional water costs.


Energies ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 6669
Author(s):  
Jerzy Sowa ◽  
Maciej Mijakowski

Humidity-sensitive, demand-controlled ventilation systems have been in use for many years in regions with oceanic climates. Some attempts have been made to apply this technology in Poland, which has a continental climate. This article evaluates the performance and energy consumption of such a system when applied in an eight-floor, multiunit, residential building, i.e., the virtual reference building described by the National Energy Conservation Agency (NAPE), Poland. Simulations using the computer program CONTAM were performed for the whole heating season based upon the climate in Warsaw. Besides passive stack ventilation, that served as a reference, two ventilation systems were studied: one standard and one “hybrid” system with additional roof fans. This study confirmed that the application of humidity-sensitive, demand-controlled ventilation in multiunit residential buildings in a continental climate (Dfb) led to significant energy savings (up to 11.64 kWh/m2 of primary energy). However, the operation of the system on higher floors was found to be ineffective. Ensuring consistent operation of the system on all floors required supplementary fans. The introduction of a hybrid mode reduced carbon dioxide concentrations by approximately 32% in the units located in the upper part of the building. The energetic effect in such cases depends strongly on the electricity source. In the case of the national energy grid, savings of primary energy would be relatively low, i.e., 1.07 kWh/m2, but in the case of locally produced renewable energy, the energy savings would be equal to 5.18 kWh/m2.


Energies ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 1912 ◽  
Author(s):  
Vasco Granadeiro ◽  
Margarida Almeida ◽  
Tiago Souto ◽  
Vítor Leal ◽  
João Machado ◽  
...  

This work addresses the effect of using thermochromic paints in residential buildings. Two different thermochromic paint types were considered: One that changes properties through a step transition at a certain temperature, and another that changes properties in a gradual/linear manner throughout a temperature range. The studied building was a two-floor villa, virtually simulated through a digital model with and without thermal insulation, and considering thermochromic paints applied both on external walls and on the roof. The performance assessment was done through the energy use for heating and cooling (in conditioned mode), as well as in terms of the indoor temperature (in free-floating mode). Three different cities/climates were considered: Porto, Madrid, and Abu Dhabi. Results showed that energy savings up to 50.6% could be reached if the building is operated in conditioned mode. Conversely, when operated in free-floating mode, optimally selected thermochromic paints enable reductions up to 11.0 °C, during summertime, and an increase up to 2.7 °C, during wintertime. These results point out the great benefits of using optimally selected thermochromic paints for obtaining thermal comfort, and also the need to further develop stable and cost-effective thermochromic pigments for outdoor applications, as well as to test physical models in a real environment.


Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4749
Author(s):  
Taesub Lim ◽  
Woong Seog Yim ◽  
Daeung Danny Kim

Accounting for more than half of buildings in South Korea, the energy consumed by residential buildings has become a main concern and the cooing demand has rapidly increased. To reduce energy consumption, several passive and active design strategies have generally been applied. However, there has been an increasing demand for high window-to-wall ratios in residential buildings, it is imperative to block sunlight into a building effectively. Focusing on the reduction of cooling energy consumption in a residential building, the present study assessed the daylight and energy performance of shading devices. Among various types of shading devices, the Venetian blind, horizontal louver, light shelf, and egg-crate were selected. The illuminance levels in three different areas in a building were measured. In addition, the annual cooling energy consumption by these shading devices was investigated. As a result, both daylight and energy performance varied with different design options of these shading devices. Because of the slight performance difference among shading devices, the artificial loads of two best shading devices were compared. In sum, the egg-crate shading was the most proper shading device to block sunlight as well as reduce the cooling energy consumption effectively.


Author(s):  
E.V. Vitvitskaya ◽  
◽  
D.V. Tarasevich ◽  

Abstract. State regulations on the design of lighting in residential buildings in recent years have undergone significant changes, which in turn will significantly affect the architecture and energy efficiency of modern buildings of this type. This can be observed from the authors' analysis of the change in only one regulatory document given in this article – SCS (State Construction Standards) V.2.5-28: «Natural and artificial lighting» and only one lighting indicator: permissible deviation of the calculated value of CNL (coefficient of natural lighting) from the standardized value when choosing translucent structures of buildings. This article presents an analysis of this normative document in two versions – in the old one from 2012 and new from 2018. Based on the results of the analysis, the authors of this article found that, at the request of the architect, the area of translucent structures on the facades of two identical modern residential buildings can differ significantly: from the minimum with piece (separate) windows on the facades – where glazing occupies from 14.3% to 18.3% of the area of the facades; up to maximum with continuous glazing of facades – where glazing occupies up to 100% of the area of the facades of a residential building. These two facade glazing options are not only architecturally perceived differently, but they must also have different energy efficiency in order to provide different minimum allowable values of heat transfer resistance: for piece (individual) windows on the facade, this is R∑ ≥ Rq min = 0.6 m2•K/W and ordinary silicate glasses are suitable for their glazing, and for continuous glazing of the facade this should already be R∑ ≥ Rq min = 2.8 m2•K/W, that is, they must have the same heat-shielding properties as the outer walls, and their minimum allowable value of the heat transfer resistance must be 4.66 times more than for piece (separate) windows. For this option, ordinary silicate glass is no longer suitable, but modern glass-transparent structures with high heat-shielding properties should be used, for example Qbiss_Air, Pilkington, Heat Mirror Glass and others. They provide excellent protection against hypothermia in winter and overheating in summer, and have good sun protection properties. Their use in modern buildings contributes to energy savings for heating and cooling rooms throughout the year and creates increased comfort, but such translucent structures are much more expensive and better suited for elite housing construction than for social.


2019 ◽  
pp. 728-755
Author(s):  
M. Mustafa Erdoğdu ◽  
Coşkun Karaca ◽  
Ali Kurultay

The amount of energy consumption in the residential buildings has a very significant share with nearly 30 percent in the total amount of energy consumption. Therefore, residential sector is identified in this chapter as being one of the areas with a large potential for energy savings. Inefficient dwelling construction and design methods are widely used in Turkey and only about five percent of residential buildings are insulated. Concerning the importance and immediate need in Turkey for energy-efficient residential building retrofitting, this chapter identifies economic benefits of such retrofitting by particularly focusing on heat transfers by conductivity, where the rate can be determined by surface size, thermal resistance of the building materials and their thickness.


Author(s):  
M. Mustafa Erdoğdu ◽  
Coşkun Karaca ◽  
Ali Kurultay

The amount of energy consumption in the residential buildings has a very significant share with nearly 30 percent in the total amount of energy consumption. Therefore, residential sector is identified in this chapter as being one of the areas with a large potential for energy savings. Inefficient dwelling construction and design methods are widely used in Turkey and only about five percent of residential buildings are insulated. Concerning the importance and immediate need in Turkey for energy-efficient residential building retrofitting, this chapter identifies economic benefits of such retrofitting by particularly focusing on heat transfers by conductivity, where the rate can be determined by surface size, thermal resistance of the building materials and their thickness.


2019 ◽  
Vol 11 (18) ◽  
pp. 4816 ◽  
Author(s):  
Maria-Mar Fernandez-Antolin ◽  
José del Río ◽  
Vincenzo Costanzo ◽  
Francesco Nocera ◽  
Roberto-Alonso Gonzalez-Lezcano

The Passive House (PH) concept is considered an efficient strategy to reduce energy consumption in the building sector, where most of the energy is used for heating and cooling applications. For this reason, energy efficiency measures are increasingly implemented in the residential sector, which is the main responsible for such a consumption. The need for professionals dealing with energy issues, and particularly for architects during the early stages of their architectural design, is crucial when considering energy efficient buildings. Therefore, architects involved in the design and construction stages have key roles in the process of enhancing energy efficiency in buildings. This research work explores the energy efficiency and optimized architectural design for residential buildings located in different climate zones in Spain, with an emphasis on Building Performance Simulation (BPS) as the key tool for architects and other professionals. According to a parametric analysis performed using Design Builder, the following optimal configurations are found for typical residential building projects: North-to-South orientation in all the five climate zones, a maximum shape factor of 0.48, external walls complying with the maximum U-value prescribed by Spanish Building Technical Code (0.35 Wm−2K−1) and a Window-to-Wall Ratio of no more than 20%. In terms of solar reflectance, it is found that the use of light colors is better in hotter climate zones A4, B4, and C4, whereas the best option is using darker colors in the colder climate zones D3 and E1. These measures help reaching the energy demand thresholds set by the Passivhaus Standard in all climate zones except for those located in climates C4, D3 and E1, for which further passive design measures are needed.