scholarly journals Discriminating complicated from uncomplicated appendicitis by ultrasound imaging, computed tomography or magnetic resonance imaging: systematic review and meta-analysis of diagnostic accuracy

BJS Open ◽  
2020 ◽  
Vol 5 (2) ◽  
Author(s):  
W J Bom ◽  
M D Bolmers ◽  
S L Gans ◽  
C C van Rossem ◽  
A A W van Geloven ◽  
...  

Abstract Background Discriminating complicated from uncomplicated appendicitis is crucial. Patients with suspected complicated appendicitis are best treated by emergency surgery, whereas those with uncomplicated appendicitis may be treated with antibiotics alone. This study aimed to obtain summary estimates of the accuracy of ultrasound imaging, CT and MRI in discriminating complicated from uncomplicated appendicitis Methods A systematic literature review was conducted by an electronic search in PubMed, Embase and the Cochrane Library for studies describing the diagnostic accuracy of complicated versus uncomplicated appendicitis. Studies were included if the population comprised adults, and surgery or pathology was used as a reference standard. Risk of bias and applicability were assessed with QUADAS-2. Bivariable logitnormal random-effect models were used to estimate mean sensitivity and specificity. Results Two studies reporting on ultrasound imaging, 11 studies on CT, one on MRI, and one on ultrasonography with conditional CT were included. Summary estimates for sensitivity and specificity in detecting complicated appendicitis could be calculated only for CT, because of lack of data for the other imaging modalities. For CT, mean sensitivity was 78 (95 per cent c.i. 64 to 88) per cent, and mean specificity was 91 (85 to 99) per cent. At a median prevalence of 25 per cent, the positive predictive value of CT for complicated appendicitis would be 74 per cent and its negative predictive value 93 per cent. Conclusion Ultrasound imaging, CT and MRI have limitations in discriminating between complicated and uncomplicated appendicitis. Although CT has far from perfect sensitivity, its negative predictive value for complicated appendicitis is high.

2008 ◽  
Vol 123 (5) ◽  
pp. 535-540 ◽  
Author(s):  
W-H Luk ◽  
W C Fan ◽  
R Y Y Chan ◽  
S W W Chan ◽  
K H Tse ◽  
...  

AbstractPurpose:To investigate and compare the sensitivity and specificity of computed tomography and of endoscopy, as diagnostic tests for foreign body ingestion.Materials and methods:Over a two-year period, Asian patients with suspected foreign body ingestion were studied. The clinical findings, computed tomography images, endoscopic results, treatment and outcomes were prospectively analysed.Results:Over the study period, 193 patients were admitted for foreign body ingestion, complaining of a persistent foreign body sensation in the neck. The sensitivity and specificity of computed tomography were 78 and 96 per cent, respectively; the positive predictive value was 75 per cent and the negative predictive value 97 per cent. The diagnostic accuracy of computed tomography was 94 per cent.Conclusion:Our study showed that computed tomography had high negative predictive value and accuracy in the diagnosis of foreign body ingestion. It was useful if endoscopy showed negative findings but the patient still had persistent symptoms of foreign body ingestion.


Author(s):  
Jolanta Nawrocka-Rutkowska ◽  
Iwona Szydłowska ◽  
Aleksandra Rył ◽  
Sylwester Ciećwież ◽  
Magdalena Ptak ◽  
...  

Background: Chronic pelvic pain affects approximately 15% of reproductive age women. It is mainly caused by adhesions (20–40%). Despite CPP being the main symptom of endometriosis, the disease is confirmed by laparoscopy only in 12–18% of cases. The aim of this study was to evaluate the results of laparoscopy in women with CCP and to assess the sensitivity and specificity of elements of an interview and clinical examination. Materials and methods: The study included 148 women with CPP. Each patient underwent laparoscopy. In laparoscopy, the presence of endometriosis and/or peritoneal adhesions was confirmed. Then, the sensitivity and specificity and the positive and negative predictive value of endometriosis symptoms or abnormalities in the gynecological examination were statistically calculated. Results: After previous surgery, adhesions were found in almost half (47%) of patients. In patients without a history of surgery, adhesions were diagnosed in 6.34% of patients. Endometriosis without coexisting adhesions was more often diagnosed in women without previous surgery (34.9%), compared to 10.58% in the group with a history of surgery (p < 0.05). Conclusions: Intraperitoneal adhesions are most common in women after pelvic surgery and with chronic ailments. The best results for sensitivity, specificity, positive predictive value, and negative predictive value in the diagnosis of endometriosis are found in women with irregular menstruations during which the pain increases. Laparoscopy still remains the primary diagnostic and therapeutic method for these women.


2020 ◽  
Vol 12 (1) ◽  
Author(s):  
J. W. Brakel ◽  
T. A. Berendsen ◽  
P. M. C. Callenbach ◽  
J. van der Burgh ◽  
R. J. Hissink ◽  
...  

Abstract Introduction Several countries advocate screening for aneurysms of the abdominal aorta (AAA) in selected patients. In the Netherlands, routine screening is currently under review by the National Health Council. In any screening programme, cost-efficiency and accuracy are key. In this study, we evaluate the Aorta Scan (Verathon, Amsterdam, Netherlands), a cost-effective and easy-to-use screening device based on bladder scan technology, which enables untrained personnel to screen for AAA. Methods We subjected 117 patients to an Aorta Scan and compared the results to the gold standard (abdominal ultrasound). We used statistical analysis to determine sensitivity and specificity of the Aorta Scan, as well as the positive and negative predictive values, accuracy, and inter-test agreement (Kappa). Results Sensitivity and specificity were 0.86 and 0.98, respectively. Positive predictive value was 0.98 and negative predictive value was 0.88. Accuracy was determined at 0.92 and the Kappa value was 0.85. When waist–hip circumferences (WHC) of > 115 cm were excluded, sensitivity raised to 0.96, specificity stayed 0.98, positive and negative predictive value were 0.98 and 0.96, respectively, accuracy to 0.97, and Kappa to 0.94. Conclusion Herein, we show that the Aorta Scan is a cost-effective and very accurate screening tool, especially in patients with WHC below 115 cm, which makes it a suitable candidate for implementation into clinical practice, specifically in the setting of screening selected populations for the presence of AAA.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Moshage ◽  
S Smolka ◽  
S Achenbach ◽  
F Ammon ◽  
P Ferstl ◽  
...  

Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (proximal vs. distal vessel segments) compared to invasively measured FFR in patients with suspected CAD. Methods A total of 136 vessels in which “Dual-Source”-CT coronary angiography had been performed due to suspected CAD and who were further referred for invasive coronary angiography with invasive FFR measurement within three months of the index CT examination were retrospectively identified and screened for inclusion in this analysis. Patients with either left main coronary artery stenoses, bifurcation or ostial stenoses were excluded. Invasive FFR was measured using a pressure wire (CERTUS®, St. Jude Medical, Minnesota, USA or Verrata®, Volcano, San Diego, USA). FFRCT was calculated using an on-site prototype (cFFR Version 3.0, Siemens Healthineers, Forchheim, Germany). All vessels were analyzed by an experienced observer blinded to the results of invasive FFR. Stenoses with invasively measured FFR ≤0.80 were classified as hemodynamically significant. We evaluated the diagnostic accuracy of FFRCT in proximal vs. non-proximal vessel segments. Proximal lesions included stenoses located in segment one, six, eleven and twelve. All other stenoses were categorized as distal lesions. Results Out of 136 coronary stenoses, 47 (35%) were located in proximal segments and 89 (65%) lesions were located in distal segments. Compared to invasive FFR, the sensitivity of FFRCT to correctly identify/exclude hemodynamically significant stenoses in proximal vessel segments was 93% (95% CI: 68–99.8%) and the specificity was 100% (95% CI: 89–100%), compared to a sensitivity of 72% (95% CI: 46.5–90%) and a specificity of 87% (95% CI: 77–94%) for FFRCT in distal lesions. The positive predictive value was 100% and the negative predictive value was 97% (95% CI: 82.8–99.5%) compared to a positive predictive value of 59% (95% CI: 42–93.9%) and a negative predictive value of 93% (95% CI: 85.4–96.3%) for proximal vs. distal vessel segment, respectively. This corresponds to an accuracy of 98% vs. 84%, respectively (p=0.02). ROC-Curve analysis showed a slightly higher – albeit non-significant – area under the curve for FFRCT to detect hemodynamic relevance in proximal lesions compared to distal lesions (AUC 0.95, p&lt;0.001 vs. AUC: 0.86, p&lt;0.001, respectively, p=0.2). Conclusion FFRCT obtained using an on-site prototype shows overall a high diagnostic accuracy for detecting lesions causing ischemia as compared to invasive FFR with a trend towards better diagnostic performance in proximal vessel segments. Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 10 (1) ◽  
pp. 20-25
Author(s):  
Sujan Shrestha ◽  
Mamen Prasad Gorhaly ◽  
Manil Ratna Bajracharya

Background Diabetic peripheral neuropathy (DPN) is a significant independent risk factor for diabetic foot, and an effective screening instrument is required to diagnose DPN early to prevent future ulceration and amputation. This study aims to determine the diagnostic accuracy of monofilament test to detect diabetic peripheral neuropathy. Methods This cross-sectional study was conducted in National Academy of Medical Sciences, Bir hospital, Mahabouddha, Kathmandu from February 2016 to January 2017. A total of 96 diabetic patients attending inpatient and outpatient Department were selected. Diabetic peripheral neuropathy was assessed by measurement of loss of protective sensation (LOPS) by monofilament test and compared with vibration perception threshold by standard biothesiometer. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were calculated. Results The prevalence of diabetic peripheral neuropathy was 26%. The sensitivity, specificity, positive predictive value and negative predictive value of monofilament test were found to be 92.0%, 95.8%, 88.5% and 97.1% respectively. There was strong association between LOPS by monofilament and vibration perception threshold by biothesiometer. Conclusion This study showed a strong diagnostic accuracy of monofilament test to detect DPN when compared with biothesiometer. As monofilament test is a cheap, easily available, and portable, it can be used in the periphery where biothesiometer is not available.  


2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Tahir Iqbal ◽  
Muhammad Usman Shahid ◽  
Ishfaq Ahmad Shad ◽  
Shahzad Karim Bhatti ◽  
Syed Amir Gilani ◽  
...  

ABSTRACT: BACKGROUND: A common surgical emergency is acute appendicitis. Various diagnostic tools are available to diagnosis acute appendicitis. Radiological investigations play an important role in making accurate and early diagnosis and thus preventing morbidity associated with the disease. OBJECTIVE: To determine the diagnostic accuracy of gray scale ultrasonography versus color Doppler in suspected cases of acute appendicitis. MATERIALS AND METHODS: The study was carried in the department of Radiology of Mayo Hospital, Lahore. A total of 75 patients were enrolled of age 18-40 years, both genders who were suspected cases of acute appendicitis. All patients underwent baseline investigations along with gray scale ultrasonography and color Doppler. All patients were subjected to surgery to confirm the diagnosis and findings were subjected to statistical analysis. RESULTS: The mean age of the patients was 23.25 ±10.55 and mean transverse diameter of appendix was 8.37 ±3.39. There were 62.7% males and 37.3%females. Findings of gray scale ultrasonography and color Doppler were then correlated with surgical findings to calculate the diagnostic accuracy of these modalities. The results revealed that gray scale ultrasonography sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 92.7%, 94.32%, 95%, 91.4% and 93.3% respectively, whereas color Doppler had sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 97.7%, 93.9%, 95.3%, 97% and 96% respectively. Diagnostic accuracy of both modalities together was 98.6%. CONCLUSION: Color Doppler has better diagnostic accuracy than gray scale ultrasonography for diagnosis of acute appendicitis and the combination of both modalities yields diagnostic accuracy that is similar to gold standard.


2020 ◽  
Vol 7 (3) ◽  
pp. 125-128
Author(s):  
Rida Salman ◽  
Mira Alsheikh ◽  
Rim Ismail

Background and aims: The diagnostic workup for pulmonary embolism (PE) includes D-dimer assay and computed tomographic angiography. Several D-dimer assays have been approved for PE diagnosis with different sensitivity and specificity. We aimed to study the sensitivity and specificity of the quantitative latex agglutination D-dimer assay used in a referral teaching hospital in Lebanon for the diagnosis of acute PE. Methods: Using a retrospective chart review, we studied 300 patients who had D-dimer test at Rafik Hariri University Hospital in the period between January 1, 2012 and December 31, 2013. Accordingly, 93 patients had a CT angiography after being suspected to have acute PE. A statistical table 2*2 was used to compare the results of CT angiography and D-dimer test. Results: Thirteen patients (13.97%) had PE and 60 patients (64.51%) had positive D-dimer test. Quantitative latex agglutination D-dimer assay had a sensitivity of 69%, specificity of 36%, and negative predictive value of 88%. False positive ratio was also 64%. Moreover, the receiver operating characteristic (ROC) curve was obtained with an area under the curve measuring 0.527. Conclusion: Quantitative latex agglutination D-dimer assay has a high negative predictive value; thus, it can exclude a PE diagnosis if it is associated with low clinical pretest probability.


Author(s):  
Firoozeh Ahmadi ◽  
Farnaz Akhbari ◽  
Fatemeh Niknejad ◽  
Hadieh Haghighi ◽  
Zahra Ghahremani ◽  
...  

ABSTRACT Introduction Two of the most frequent procedures performed on infertile women are two-dimensional ultrasound (2DUS) and three-dimensional ultrasound (3DUS). Hysteroscopy is considered as the gold standard for evaluation of acquired endometrial lesions in infertile women; however, 3DUS is used as a noninvasive, less expensive, and reliable assessment method for evaluation of the intrauterine lesions in infertile women. We aimed to compare the diagnostic efficiency between 3DUS and hysteroscopy in the detection of lesions (polyps, submucous leiomyoma, and synechiae) in infertile women. Materials and methods In this prospective observational study, infertile women (n = 155) with indication of hysteroscopy were scheduled to undergo 3DUS prior to hysteroscopy from September 2010 to 2011. Women with suspected congenital uterine anomalies were excluded. The sensitivity and specificity values of 3DUS were compared with those of hysteroscopy. Hysteroscopy was used as the gold standard for diagnosis of intrauterine lesions in infertile women. Results Of the 155 women, 50 were found to have an intracavitary abnormality, 36 had polyps, 12 had myomas, and 7 had synechiae on hysteroscopic findings. Examination with 3DUS in the diagnosis of intrauterine lesions reached an accuracy of 94%, and 92.15 and 96.9% of sensitivity and specificity respectively. Positive predictive value (PPV) was 83.9%, and a negative predictive value (NPV) was 91.3% (LR+ = 10.75, LR+ = 0.065). Conclusion According to our results, 3DUS has a reliable diagnostic accuracy for intrauterine lesions, and it may limit unnecessary hysteroscopy in patients with normal results. How to cite this article Ahmadi F, Haghighi H, Ghahremani Z, Niknejad F, Akhbari F, Ramezanali F, Chehrazi M. Diagnostic Accuracy of Three-dimensional Ultrasonography in Detection of Endometrial Lesions compared with Hysteroscopy in Infertile Women. Donald School J Ultrasound Obstet Gynecol 2016;10(4):393-397.


2021 ◽  
Author(s):  
Andrew Phillip Maurice ◽  
Benjamin David Swinson ◽  
Eduardo Miguel Apellaniz ◽  
Sarah Emily King ◽  
Thomas Grant Mackay ◽  
...  

Abstract BACKGROUNDEven with modern diagnostics, appendicitis can be difficult to diagnose accurately. Negative appendicectomies (NA) and delayed diagnosis of complicated appendicitis (CA, i.e. perforation or abscess) remain common. Serum bilirubin has been proposed as an additional biomarker to assist with the diagnosis of appendicitis. In this large series, we assessed the value of bilirubin in the diagnosis of appendicitis.METHODS A retrospective review of patients with suspected appendicitis at three hospitals over a three year period was performed. All consecutive patients with appendicectomy were included. In addition, a “discharged” sub-group of consecutive patients who were admitted with suspected appendicitis but discharged without an operation was also identified.Demographic data, presence of fever, tachycardia, total white cell count (WCC), neutrophil count, total serum bilirubin, operative findings and final histology were recorded. Multivariate logistic regression was performed to determine independent predictors of appendicitis and CA. Receiver-operator analysis was performed to compare bilirubin to WCC and neutrophil count.RESULTS There were 2024 patients: 1167 had uncomplicated appendicitis, 355 had CA and 303 underwent NA. 200 non-surgical "discharged" patients were included for comparison. Compared to those without appendicitis (NA and discharged groups), increased serum bilirubin was associated with an increased likelihood of appendicitis (OR 1.030 (1.013, 1.048), p<0.0001) and increased likelihood of CA (OR 1.035, 95% CI (1.021, 1.050), p<0.001). These results remained significant when the discharged group, NA group and uncomplicated appendicitis groups were analyzed separately.The sensitivity and specificity of bilirubin was inferior to neutrophil count for the diagnosis of appendicitis (AUC 0.657 versus 0.725, p<0.0001). Bilirubin, WCC and neutrophils each were all relatively insensitive and non-specific over a variety of cut-off values and combinations did not improve their accuracy.CONCLUSION Hyperbilirubinaemia was independently associated with an increased likelihood of both uncomplicated and complicated appendicitis, however had similar sensitivity and specificity when compared to WCC or neutrophils. Bilirubin, neutrophil count and WCC alone are not discriminatory enough to be used in isolation but may be incrementally useful adjuncts in pre-operative assessment of patients with suspected appendicitis.


Sign in / Sign up

Export Citation Format

Share Document