scholarly journals Technical performance evaluation of BM/Hitachi 747-200 serum fructosamine assay

1996 ◽  
Vol 42 (2) ◽  
pp. 244-248 ◽  
Author(s):  
M J Lin ◽  
C Hoke ◽  
B Ettinger ◽  
R V Coyne

Abstract The technical performance of serum fructosamine assay as a short-term index of diabetic control was evaluated by using the BM/Hitachi 747-200 Automatic Analyzer (Boehringer Mannheim Corp). Intra- and interassay precisions (CV) were <2%. Linearity was confirmed up to 1000 micromol/L. Lipemia, produced artificially or from hypertriglyceridemia in vivo, did not interfere with measurement of serum fructosamine concentration. However, hemoglobin (Hb) interfered with measurement substantially at concentrations >15.5 micromol/L, and bilirubin interfered substantially at concentrations >68.4 micromol/L. A normal reference range of up to 282 micromol/L (mean +/- 2SD = 242 +/- 40) was derived from results obtained from 228 nondiabetic subjects. In 222 diabetic subjects, serum fructosamine concentration correlated well with fasting glucose concentration (r = 0.74) and with Hb A1c concentration (r = 0.80). This automated fructosamine assay has the advantages of technical simplicity, low cost, and reduced analytical time compared with the Hb A1c method.

1987 ◽  
Vol 33 (1) ◽  
pp. 158-161 ◽  
Author(s):  
D R Jury ◽  
P J Dunn

Abstract We have evaluated the laboratory performance and clinical usefulness of the Roche fructosamine kit. As used with an Abbott ABA 100 bichromatic analyzer, the kit response varied linearly with fructosamine concentration to 5.0 mmol/L (deoxymorpholinofructose equivalents). Interbatch precision was 4.1% and 3.6% for respective fructosamine concentrations of 3.2 and 5.0 mmol/L; intrabatch precision was 3.2% and 3.0% (fructosamine = 3.0 and 4.0 mmol/L). In 55 nondiabetic subjects all fructosamine values were less than 3.0 mmol/L, 95% were less than 2.7 mmol/L. For both fructosamine and glycated hemoglobin (Hb A1c) the 95th percentile of the reference range corresponded to approximately the 10th percentile of values observed in 108 diabetic subjects. In the latter subjects fructosamine concentrations correlated somewhat (r = 0.6504) with the Hb A1c value and for eight diabetic subjects indicated a similar degree of diabetic control over a 10-week period. From assessments of sensitivity and specificity for predicting abnormal glucose tolerance in 145 subjects, we conclude that this assay of serum fructosamine reflects diabetic control about as well as Hb A1c estimation, but neither can replace the glucose tolerance test for the diagnosis of diabetes.


Author(s):  
R.J. Mount ◽  
R.V. Harrison

The sensory end organ of the ear, the organ of Corti, rests on a thin basilar membrane which lies between the bone of the central modiolus and the bony wall of the cochlea. In vivo, the organ of Corti is protected by the bony wall which totally surrounds it. In order to examine the sensory epithelium by scanning electron microscopy it is necessary to dissect away the protective bone and expose the region of interest (Fig. 1). This leaves the fragile organ of Corti susceptible to physical damage during subsequent handling. In our laboratory cochlear specimens, after dissection, are routinely prepared by the O-T- O-T-O technique, critical point dried and then lightly sputter coated with gold. This processing involves considerable specimen handling including several hours on a rotator during which the organ of Corti is at risk of being physically damaged. The following procedure uses low cost, readily available materials to hold the specimen during processing ,preventing physical damage while allowing an unhindered exchange of fluids.Following fixation, the cochlea is dehydrated to 70% ethanol then dissected under ethanol to prevent air drying. The holder is prepared by punching a hole in the flexible snap cap of a Wheaton vial with a paper hole punch. A small amount of two component epoxy putty is well mixed then pushed through the hole in the cap. The putty on the inner cap is formed into a “cup” to hold the specimen (Fig. 2), the putty on the outside is smoothed into a “button” to give good attachment even when the cap is flexed during handling (Fig. 3). The cap is submerged in the 70% ethanol, the bone at the base of the cochlea is seated into the cup and the sides of the cup squeezed with forceps to grip it (Fig.4). Several types of epoxy putty have been tried, most are either soluble in ethanol to some degree or do not set in ethanol. The only putty we find successful is “DUROtm MASTERMENDtm Epoxy Extra Strength Ribbon” (Loctite Corp., Cleveland, Ohio), this is a blue and yellow ribbon which is kneaded to form a green putty, it is available at many hardware stores.


2019 ◽  
Vol 130 ◽  
pp. 32-43 ◽  
Author(s):  
Elias Begas ◽  
Maria Bounitsi ◽  
Thomas Kilindris ◽  
Evangelos Kouvaras ◽  
Konstantinos Makaritsis ◽  
...  

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Robert Christie

Abstract This paper presents an overview of the general chemical principles underlying the structures, synthesis and technical performance of azo pigments, the dominant chemical class of industrial organic pigments in the yellow, orange, and red shade areas, both numerically and in terms of tonnage manufactured. A description of the most significant historical features in this group of pigments is provided, starting from the discovery of the chemistry on which azo colorants are based by Griess in the mid-nineteenth century, through the commercial introduction of the most important classical azo pigments in the early twentieth century, including products known as the Hansa Yellows, β-naphthol reds, including metal salt pigments, and the diarylide yellows and oranges, to the development in the 1950s and 1960s of two classes of azo pigments that exhibit high performance, disazo condensation pigments and benzimidazolone-based azo pigments. A feature that complicates the description of the chemical structures of azo pigments is that they exist in the solid state as the ketohydrazone rather than the hydroxyazo form, in which they have been traditionally been illustrated. Numerous structural studies conducted over the years on an extensive range of azo pigments have demonstrated this feature. In this text, they are referred to throughout as azo (hydrazone) pigments. Since a common synthetic procedure is used in the manufacture of virtually all azo (hydrazone) pigments, this is discussed in some detail, including practical aspects. The procedure brings together two organic components as the fundamental starting materials, a diazo component and a coupling component. An important reason for the dominance of azo (hydrazone) pigments is that they are highly cost-effective. The syntheses generally involve low cost, commodity organic starting materials and are carried out in water as the reaction solvent, which offers obvious economic and environmental advantages. The versatility of the approach means that an immense number of products may be prepared, so that they have been adapted structurally to meet the requirements of many applications. On an industrial scale, the processes are straightforward, making use of simple, multi-purpose chemical plant. Azo pigments may be produced in virtually quantitative yields and the processes are carried out at or below ambient temperatures, thus presenting low energy requirements. Finally, provided that careful control of the reaction conditions is maintained, azo pigments may be prepared directly by an aqueous precipitation process that can optimise physical form, with control of particle size distribution, crystalline structure, and surface character. The applications of azo pigments are outlined, with more detail reserved for subsequent papers on individual products.


Author(s):  
Daniel L. Villeneuve ◽  
Brett R. Blackwell ◽  
Jenna E. Cavallin ◽  
Wan‐Yun Cheng ◽  
David J. Feifarek ◽  
...  

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Woo Seok Kim ◽  
Sungcheol Hong ◽  
Milenka Gamero ◽  
Vivekanand Jeevakumar ◽  
Clay M. Smithhart ◽  
...  

AbstractThe vagus nerve supports diverse autonomic functions and behaviors important for health and survival. To understand how specific components of the vagus contribute to behaviors and long-term physiological effects, it is critical to modulate their activity with anatomical specificity in awake, freely behaving conditions using reliable methods. Here, we introduce an organ-specific scalable, multimodal, wireless optoelectronic device for precise and chronic optogenetic manipulations in vivo. When combined with an advanced, coil-antenna system and a multiplexing strategy for powering 8 individual homecages using a single RF transmitter, the proposed wireless telemetry enables low cost, high-throughput, and precise functional mapping of peripheral neural circuits, including long-term behavioral and physiological measurements. Deployment of these technologies reveals an unexpected role for stomach, non-stretch vagal sensory fibers in suppressing appetite and demonstrates the durability of the miniature wireless device inside harsh gastric conditions.


Author(s):  
Laura Wienands ◽  
Franziska Theiß ◽  
James Eills ◽  
Lorenz Rösler ◽  
Stephan Knecht ◽  
...  

AbstractParahydrogen-induced polarization is a hyperpolarization method for enhancing nuclear magnetic resonance signals by chemical reactions/interactions involving the para spin isomer of hydrogen gas. This method has allowed for biomolecules to be hyperpolarized to such a level that they can be used for real time in vivo metabolic imaging. One particularly promising example is fumarate, which can be rapidly and efficiently hyperpolarized at low cost by hydrogenating an acetylene dicarboxylate precursor molecule using parahydrogen. The reaction is relatively slow compared to the timescale on which the hyperpolarization relaxes back to thermal equilibrium, and an undesirable 2nd hydrogenation step can convert the fumarate into succinate. To date, the hydrogenation chemistry has not been thoroughly investigated, so previous work has been inconsistent in the chosen reaction conditions in the search for ever-higher reaction rate and yield. In this work we investigate the solution preparation protocols and the reaction conditions on the rate and yield of fumarate formation. We report conditions to reproducibly yield over 100 mM fumarate on a short timescale, and discuss aspects of the protocol that hinder the formation of fumarate or lead to irreproducible results. We also provide experimental procedures and recommendations for performing reproducible kinetics experiments in which hydrogen gas is repeatedly bubbled into an aqueous solution, overcoming challenges related to the viscosity and surface tension of the water.


2020 ◽  
Author(s):  
Joost van Haasteren ◽  
Altar M Munis ◽  
Deborah R Gill ◽  
Stephen C Hyde

Abstract The gene and cell therapy fields are advancing rapidly, with a potential to treat and cure a wide range of diseases, and lentivirus-based gene transfer agents are the vector of choice for many investigators. Early cases of insertional mutagenesis caused by gammaretroviral vectors highlighted that integration site (IS) analysis was a major safety and quality control checkpoint for lentiviral applications. The methods established to detect lentiviral integrations using next-generation sequencing (NGS) are limited by short read length, inadvertent PCR bias, low yield, or lengthy protocols. Here, we describe a new method to sequence IS using Amplification-free Integration Site sequencing (AFIS-Seq). AFIS-Seq is based on amplification-free, Cas9-mediated enrichment of high-molecular-weight chromosomal DNA suitable for long-range Nanopore MinION sequencing. This accessible and low-cost approach generates long reads enabling IS mapping with high certainty within a single day. We demonstrate proof-of-concept by mapping IS of lentiviral vectors in a variety of cell models and report up to 1600-fold enrichment of the signal. This method can be further extended to sequencing of Cas9-mediated integration of genes and to in vivo analysis of IS. AFIS-Seq uses long-read sequencing to facilitate safety evaluation of preclinical lentiviral vector gene therapies by providing IS analysis with improved confidence.


2020 ◽  
Vol 18 ◽  
pp. 228080002097517
Author(s):  
Yuan-ming Geng ◽  
Dong-ni Ren ◽  
Shu-yi Li ◽  
Zong-yi Li ◽  
Xiao-qing Shen ◽  
...  

Background: Poly Ether Ether Ketone (PEEK) has been considered as a potential alternative material for endosseous dental implants, for its low elastic modulus, biocompatibility, and low cost in customized device manufacture. Hydroxyapatite-incorporation is supposed to improve the poor osseointegration of PEEK. Methods: In the present study we analyzed the in vivo response of hydroxyapatite-incorporated PEEK (PEEK-HA) implants in canine tibia. PEEK-HA and PEEK implants were implanted and were examined 4 weeks and 12 weeks after implantation with radiology and histology. Commercial titanium dental implants served as controls. Results: The ratio of bone volume to tissue volume of PEEK-HA implants was higher than that of PEEK implants 4 weeks after implantation in the μ-CT analysis. The bone implant contact of PEEK and PEEK-HA implants showed no statistical difference in the histological examination, but newly-formed bone around PEEK-HA implants showed more signs of mineralization than that around PEEK implants. Conclusion: The study suggested that bone formation was improved with hydroxyapatite-incorporation in PEEK. Hydroxyapatite-incorporated PEEK implants may represent a potential material for endosseous dental implant.


Author(s):  
Xiu‐Shi Zhang ◽  
En‐Hui Liu ◽  
Xin‐Yu Wang ◽  
Xin‐Xiang Zhou ◽  
Hong‐Xia Zhang ◽  
...  

Sign in / Sign up

Export Citation Format