scholarly journals Immunoassay as an Analytical Tool in Agricultural Biotechnology

2006 ◽  
Vol 89 (4) ◽  
pp. 913-928 ◽  
Author(s):  
G David Grothaus ◽  
Murali Bandla ◽  
Thomas Currier ◽  
Randal Giroux ◽  
G Ronald Jenkins ◽  
...  

Abstract Immunoassays for biotechnology engineered proteins are used by AgBiotech companies at numerous points in product development and by feed and food suppliers for compliance and contractual purposes. Although AgBiotech companies use the technology during product development and seed production, other stakeholders from the food and feed supply chains, such as commodity, food, and feed companies, as well as third-party diagnostic testing companies, also rely on immunoassays for a number of purposes. The primary use of immunoassays is to verify the presence or absence of genetically modified (GM) material in a product or to quantify the amount of GM material present in a product. This article describes the fundamental elements of GM analysis using immunoassays and especially its application to the testing of grains. The 2 most commonly used formats are lateral flow devices (LFD) and plate-based enzyme-linked immunosorbent assays (ELISA). The main applications of both formats are discussed in general, and the benefits and drawbacks are discussed in detail. The document highlights the many areas to which attention must be paid in order to produce reliable test results. These include sample preparation, method validation, choice of appropriate reference materials, and biological and instrumental sources of error. The article also discusses issues related to the analysis of different matrixes and the effects they may have on the accuracy of the immunoassays.

2013 ◽  
Vol 548 ◽  
pp. 247-252 ◽  
Author(s):  
Hüseyin Ankara ◽  
Mehmet Aksoy ◽  
Suheyla Yerel ◽  
Yasar Keser

In this study, the preparation method of the equivalent sized spherical samples which is called as Pasha Method is applied to slake durability index test. In order to apply this sample preparation method, white and pink tuff samples were collected at the tuff quarries located at the Eskisehir region in Turkey. After sample preparation stage, these tuff samples were subjected to the Slake Durability Index test in the laboratory. According to the test results presented in this paper, the highest slake durability index values were obtained from equal-sized spherical test samples that are prepared according to the new method, Pasha Method, when compared to the other two types of samples.


2005 ◽  
Vol 88 (1) ◽  
pp. 136-155 ◽  
Author(s):  
Markus Lipp ◽  
Raymond Shillito ◽  
Randal Giroux ◽  
Frank Spiegelhalter ◽  
Stacy Charlton ◽  
...  

Abstract The agricultural biotechnology industry applies polymerase chain reaction (PCR) technology at numerous points in product development. Commodity and food companies as well as third-party diagnostic testing companies also rely on PCR technology for a number of purposes. The primary use of the technology is to verify the presence or absence of genetically modified (GM) material in a product or to quantify the amount of GM material present in a product. This article describes the fundamental elements of PCR analysis and its application to the testing of grains. The document highlights the many areas to which attention must be paid in order to produce reliable test results. These include sample preparation, method validation, choice of appropriate reference materials, and biological and instrumental sources of error. The article also discusses issues related to the analysis of different matrixes and the effect they may have on the accuracy of the PCR analytical results.


2020 ◽  
Vol 43 ◽  
Author(s):  
Michael Tomasello

Abstract My response to the commentaries focuses on four issues: (1) the diversity both within and between cultures of the many different faces of obligation; (2) the possible evolutionary roots of the sense of obligation, including possible sources that I did not consider; (3) the possible ontogenetic roots of the sense of obligation, including especially children's understanding of groups from a third-party perspective (rather than through participation, as in my account); and (4) the relation between philosophical accounts of normative phenomena in general – which are pitched as not totally empirical – and empirical accounts such as my own. I have tried to distinguish comments that argue for extensions of the theory from those that represent genuine disagreement.


Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


Author(s):  
Chuan Zhang ◽  
Jane Y. Li ◽  
John Aguada ◽  
Howard Marks

Abstract This paper introduces a novel sample preparation method using plasma focused ion-beam (pFIB) milling at low grazing angle. Efficient and high precision preparation of site-specific cross-sectional samples with minimal alternation of device parameters can be achieved with this method. It offers the capability of acquiring a range of electrical characteristic signals from specific sites on the cross-section of devices, including imaging of junctions, Fins in the FinFETs and electrical probing of interconnect metal traces.


Author(s):  
Swaminathan Subramanian ◽  
Khiem Ly ◽  
Tony Chrastecky

Abstract Visualization of dopant related anomalies in integrated circuits is extremely challenging. Cleaving of the die may not be possible in practical failure analysis situations that require extensive electrical fault isolation, where the failing die can be submitted of scanning probe microscopy analysis in various states such as partially depackaged die, backside thinned die, and so on. In advanced technologies, the circuit orientation in the wafer may not align with preferred crystallographic direction for cleaving the silicon or other substrates. In order to overcome these issues, a focused ion beam lift-out based approach for site-specific cross-section sample preparation is developed in this work. A directional mechanical polishing procedure to produce smooth damage-free surface for junction profiling is also implemented. Two failure analysis applications of the sample preparation method to visualize junction anomalies using scanning microwave microscopy are also discussed.


Molecules ◽  
2021 ◽  
Vol 26 (8) ◽  
pp. 2277
Author(s):  
Piotr M. Kuś ◽  
Igor Jerković

Recently, we proposed a new sample preparation method involving reduced solvent and sample usage, based on dehydration homogeneous liquid–liquid extraction (DHLLE) for the screening of volatiles and semi-volatiles from honey. In the present research, the method was applied to a wide range of honeys (21 different representative unifloral samples) to determine its suitability for detecting characteristic honey compounds from different chemical classes. GC-FID/MS disclosed 130 compounds from different structural and chemical groups. The DHLLE method allowed the extraction and identification of a wide range of previously reported specific and nonspecific marker compounds belonging to different chemical groups (including monoterpenes, norisoprenoids, benzene derivatives, or nitrogen compounds). For example, DHLLE allowed the detection of cornflower honey chemical markers: 3-oxo-retro-α-ionols, 3,4-dihydro-3-oxoedulan, phenyllactic acid; coffee honey markers: theobromine and caffeine; linden honey markers: 4-isopropenylcyclohexa-1,3-diene-1-carboxylic acid and 4-(2-hydroxy-2-propanyl)cyclohexa-1,3-diene-1-carboxylic acid, as well as furan derivatives from buckwheat honey. The obtained results were comparable with the previously reported data on markers of various honey varieties. Considering the application of much lower volumes of very common reagents, DHLLE may provide economical and ecological advantages as an alternative sample preparation method for routine purposes.


Sign in / Sign up

Export Citation Format

Share Document