scholarly journals Characteristics of children and antigen test performance at a SARS-CoV-2 community testing site

Author(s):  
Laura Ford ◽  
Melissa J. Whaley ◽  
Melisa M. Shah ◽  
Phillip P. Salvatore ◽  
Hannah E. Segaloff ◽  
...  

Background: Performance characteristics of SARS-CoV-2 antigen tests among children are limited despite the need for point-of-care testing in school and childcare settings. We describe children seeking SARS-CoV-2 testing at a community site and compare antigen test performance to real-time reverse transcription-polymerase chain reaction (RT-PCR) and viral culture. Methods: Two anterior nasal specimens were self-collected for BinaxNOW antigen and RT-PCR testing, along with demographics, symptoms, and exposure information from individuals ≥5 years at a community testing site. Viral culture was attempted on residual antigen or RT-PCR positive specimens. Demographic and clinical characteristics, and the performance of SARS-CoV-2 antigen tests, were compared among children (<18 years) and adults. Results: About one in ten included specimens were from children (225/2110); 16.4% (37/225) were RT-PCR positive. Cycle threshold values were similar among RT-PCR positive specimens from children and adults (22.5 vs 21.3, p=0.46) and among specimens from symptomatic and asymptomatic children (22.5 vs 23.2, p=0.39). Sensitivity of antigen test compared to RT-PCR was 73.0% (27/37) among specimens from children and 80.8% (240/297) among specimens from adults; among specimens from children, specificity was 100% (188/188), positive and negative predictive value were 100% (27/27) and 94.9% (188/198) respectively. Virus was isolated from 51.4% (19/37) of RT-PCR positive pediatric specimens; all 19 had positive antigen test results. Conclusions : With lower sensitivity relative to RT-PCR, antigen tests may not diagnose all positive COVID-19 cases; however, antigen testing identified children with live SARS-CoV-2 virus.

PLoS ONE ◽  
2021 ◽  
Vol 16 (4) ◽  
pp. e0249710
Author(s):  
Neeraj Sood ◽  
Rashmi Shetgiri ◽  
Anna Rodriguez ◽  
Dianna Jimenez ◽  
Sonia Treminino ◽  
...  

Background Rapid antigen tests hold much promise for use in the school environment. However, the performance of these tests in non-clinical settings and among one of the main target populations in schools—asymptomatic children—is unclear. To address this gap, we examined the positive and negative concordance between the BinaxNOW™ rapid SARS-CoV-2 antigen assay and an RT-PCR test among children at a community-based Covid-19 testing site. Methods We conducted rapid antigen (BinaxNOW™) and oral fluid RT-PCR (Curative Labs) tests on children presenting at a walk-up testing site in Los Angeles County from November 25, 2020 to December 9, 2020. Positive concordance was determined as the fraction of RT-PCR positive participants that were also antigen positive. Negative concordance was determined as the fraction of RT-PCR negative participants that were also antigen negative. Multivariate logistic regression models were used to examine the association between positive or negative concordance and participant age, race-ethnicity, sex at birth, symptoms and Ct values. Results 226 children tested positive on RT-PCR; 127 children or 56.2% (95% CI: 49.5% to 62.8%) of these also tested positive on the rapid antigen test. Positive concordance was higher among symptomatic children (64.4%; 95% CI: 53.4% to 74.4%) compared to asymptomatic children (51.1%; 95% CI: 42.5% to 59.7%). Positive concordance was negatively associated with Ct values and was 93.8% (95% CI: 69.8% to 99.8%) for children with Ct values less than or equal to 25. 548 children tested negative on RT-PCR; 539 or 98.4% (95% CI: 96.9% to 99.2%) of these also tested negative on the rapid antigen test. Negative concordance was higher among asymptomatic children. Conclusions Rapid antigen testing can successfully identify most COVID infections in children with viral load levels likely to be infectious. Serial rapid testing may help compensate for limited sensitivity in early infection.


2021 ◽  
Author(s):  
Nira R. Pollock ◽  
Kristine Tran ◽  
Jesica R. Jacobs ◽  
Amber E. Cranston ◽  
Sita Smith ◽  
...  

AbstractBackgroundTo facilitate deployment of point-of-care testing for SARS-CoV-2, we evaluated the Access Bio CareStart COVID-19 Antigen test in a high-throughput, drive-through, free community testing site using anterior nasal (AN) swab RT-PCR for clinical testing.MethodsConsenting symptomatic and asymptomatic children (≤18 years) and adults received dual AN swabs. CareStart testing was performed with temperature/humidity monitoring. All tests had two independent reads to assess inter-operator agreement. Patients with positive CareStart results were called and instructed to isolate pending RT-PCR results. The paired RT-PCR result was the reference for sensitivity and specificity calculations.ResultsOf 1603 participants, 1245 adults and 253 children had paired RT-PCR/CareStart results and complete symptom data. 83% of adults and 87% of children were asymptomatic. CareStart sensitivity/specificity were 84.8% (95% confidence interval [CI] 71.1-93.7)/97.2% (92.0-99.4) and 85.7% (42.1-99.6)/89.5% (66.9-98.7) in adults and children, respectively, within 5 days of symptoms. Sensitivity/specificity were 50.0% (41.0-59.0)/99.1% (98.3-99.6) in asymptomatic adults and 51.4% (34.4-68.1)/97.8% (94.5-99.4) in asymptomatic children. Sensitivity in all 234 RT-PCR-positive people was 96.3% with cycle threshold (Ct) ≤25, 79.6% with Ct ≤30, and 61.4% with Ct ≤35. All 21 false positive CareStart tests had faint but normal bands. Inter-operator agreement was 99.5%. Operational challenges included identification of faint test bands and inconsistent swab elution volumes.ConclusionsCareStart had high sensitivity in people with Ct ≤25 and moderate sensitivity in symptomatic people overall. Specificity was unexpectedly lower in symptomatic versus asymptomatic people. Excellent inter-operator agreement was observed, but operational challenges indicate that operator training is warranted.


Author(s):  
Nira R Pollock ◽  
Kristine Tran ◽  
Jesica R Jacobs ◽  
Amber E Cranston ◽  
Sita Smith ◽  
...  

Abstract Background To facilitate deployment of point-of-care testing for SARS-CoV-2, we evaluated the Access Bio CareStart COVID-19 Antigen test in a high-throughput, drive-through, free community testing site using anterior nasal (AN) swab RT-PCR for clinical testing. Methods Consenting symptomatic and asymptomatic children (≤18 years) and adults received dual AN swabs. CareStart testing was performed with temperature/humidity monitoring. All tests had two independent reads to assess inter-operator agreement. Patients with positive CareStart results were called and instructed to isolate pending RT-PCR results. The paired RT-PCR result was the reference for sensitivity and specificity calculations. Results Of 1603 participants, 1245 adults and 253 children had paired RT-PCR/CareStart results and complete symptom data. 83% of adults and 87% of children were asymptomatic. CareStart sensitivity/specificity were 84.8% (95% confidence interval [CI] 71.1-93.7)/97.2% (92.0-99.4) and 85.7% (42.1-99.6)/89.5% (66.9-98.7) in adults and children, respectively, within 5 days of symptoms. Sensitivity/specificity were 50.0% (41.0-59.0)/99.1% (98.3-99.6) in asymptomatic adults and 51.4% (34.4-68.1)/97.8% (94.5-99.4) in asymptomatic children. Sensitivity in all 234 RT-PCR-positive people was 96.3% with cycle threshold (Ct) ≤25, 79.6% with Ct ≤30, and 61.4% with Ct ≤35. All 21 false positive CareStart tests had faint but normal bands. Inter-operator agreement was 99.5%. Operational challenges included identification of faint test bands and inconsistent swab elution volumes. Conclusions CareStart had high sensitivity in people with Ct ≤25 and moderate sensitivity in symptomatic people overall. Specificity was unexpectedly lower in symptomatic versus asymptomatic people. Excellent inter-operator agreement was observed, but operational challenges indicate that operator training is warranted.


2021 ◽  
Author(s):  
Jesse Gitaka ◽  
Eva Muthamia ◽  
Samuel Mbugua ◽  
Mary Mungai ◽  
Gama Bandawe ◽  
...  

Abstract Background: The COVID-19 pandemic has resulted in a need for rapid identification of infectious cases. Testing barriers have prohibited adequate screening for SARS COV2, resulting in significant delays in treatment provision and commencement of outbreak control measures. This study aimed to generate evidence on the performance and implementation characteristics of the BD Veritor rapid antigen test as compared to the gold standard test for diagnosis of SARS COV2 in Kenya. Methods: This was a field test performance evaluation in symptomatic and asymptomatic adults undergoing testing for SARS COV2. Recruited participants were classified as SARS-CoV2-positive based on the locally implemented gold standard reverse transcription polymerase chain reaction (RT-PCR) test performed on nasopharyngeal swabs. 272 antigen tests were performed with simultaneous gold standard testing, allowing us to estimate sensitivity, specificity, positive and negative predictive values for the BD Veritor rapid antigen test platform. Implementation characteristics were assessed using the Consolidated Framework for Implementation Research for feasibility, acceptability, turn-around time, and ease-of-use metrics. Results and Discussion: We enrolled 97 PCR negative symptomatic and 128 PCR negative asymptomatic, and 28 PCR positive symptomatic and 19 PCR positive asymptomatic participants. Compared to the gold standard, the sensitivity of the BD Veritor antigen test was 94% (95% confidence interval [CI] 86.6 to 100.0) while the specificity was 98% (95% confidence interval [CI] 96 to 100). The sensitivity of BD Veritor antigen test was higher among symptomatic (100%) compared to asymptomatic (84%) participants, although this difference was not statistically significant. There was also a lack of association between cycle threshold value and sensitivity of BD Veritor test. The BD Veritor test had quick turnaround time and minimal resource requirements, and laboratory personnel conducting testing felt that it was easier to use than the gold standard RT-PCR. Conclusion: The BD Veritor rapid antigen test exhibited excellent sensitivity and specificity when used to detect SARS-CoV-2 infection among both symptomatic and asymptomatic individuals in varied population settings in Kenya. It was feasible to implement and easy to use, with rapid turnaround time.


Author(s):  
Mar Masiá ◽  
Marta Fernández-González ◽  
Manuel Sánchez ◽  
Mar Carvajal ◽  
José Alberto García ◽  
...  

Abstract Background Performance of point-of-care tests in different clinical scenarios and on different samples remains undetermined. We comprehensively evaluated the performance of the nasopharyngeal Panbio COVID-19 antigen Rapid-Test-Device. Method Prospective study including consecutive patients attending three primary care centers (PCC) and an emergency department. The antigen test was performed at point-of-care in nasopharyngeal and nasal swabs, and in saliva. Positive and negative percent agreement (PPA, NPA) were calculated with the RT-PCR assay as reference standard. Results Of 913 patients included, 296 (32.3%) were asymptomatic and 690 (75.6%) came from the PCC. Nasopharyngeal swabs were collected from 913, nasal swabs from 659, and saliva from 611 patients. RT-PCR was positive in 196 (21.5%) nasopharyngeal samples (NPS). Overall PPA (95% CI) in NPS was 60.5% (53.3-67.4), and it was lower in nasal swabs (44.7%) and saliva (23.1%). Test performance in NPS was largely dependent on the cycle threshold (Ct) in RT-PCR, with PPA of 94% for Ct≤25 and 80% for Ct&lt;30. In symptomatic patients, the PPA was 95% for Ct≤25; 85% for Ct&lt;30, and 89% for the symptom triad of fever, cough and malaise. Performance was also dependent on age, with PPA of 100% in symptomatic patients &gt;50 years with Ct&lt;25. In asymptomatic patients, the PPA was 86% for Ct&lt;25. In all cases, NPA was 100%. Conclusion The nasopharyngeal Panbio COVID-19 antigen test performed at point-of-care has a good sensitivity in symptomatic patients with Ct&lt;30 and older age. The test was useful to identify asymptomatic patients with lower Ct values.


2021 ◽  
Vol 8 ◽  
Author(s):  
Mohammad Alghounaim ◽  
Hamad Bastaki ◽  
Farah Bin Essa ◽  
Hoda Motlagh ◽  
Salman Al-Sabah

Background: SARS-CoV-2 antigen assays offer a rapid mean to diagnose and isolate infected individuals. However, their utility in population-level screening is unknown.Objectives: The performance of two antigen tests in detecting SARS-CoV-2 was assessed among individuals randomly selected in the community.Study Design: A prospective study that performed head-to-head comparison of two SARS-CoV-2 antigen assays. Individuals were recruited during community SARS-CoV-2 screening over 10 working days. Demographic and clinical data were collected. Standard Q COVID-19 Ag test, a point-of-care chromatographic assay, was conducted immediately, and then the sample was transported to the virology laboratory to perform PCR and the LIAISON SARS-CoV-2 Ag chemiluminesence immunoassay.Results: respiratory samples from 991 individuals were collected, and 62 were positive by PCR. Inconclusive PCR results were observed in 19 samples and were excluded. The median age of participants was 40.2 years (IQR 32.3–47.8), and 932 (94%) were males. Most (77.4%) of infections were asymptomatic. The sensitivity and the specificity of the LIAISON assay were 43.3% (95%CI 30.6–56.8) and 99.9% (95%CI 99.3–100). The Standard Q assay had lower sensitivity (30.6%, 95%CI 19.6–43.7) but similar specificity (98.8%, 95%CI, 97.8–99.4). Similarly, the LIAISON assay had higher positive predictive value (96.3%, 95%CI 81–99.9% vs. 63.3%, 95%CI, 43.9–80.1%). Both assays performed better in symptomatic patients and among samples with a low-cycle threshold (Ct &lt; 25).Conclusion: In our setting of random community surveillance, rapid antigen testing of nasopharyngeal swabs by either LIAISON SARS-CoV-2 Ag (DiaSorin) or Standard Q COVID-19 Ag (SD Biosensor) was less sensitive to detecting SARS-CoV-2 than the TaqPath COVID-19 RT-PCR.


2022 ◽  
Author(s):  
Kristie J Sun ◽  
Mary Jane E Vaeth ◽  
Matthew L Robinson ◽  
Maryam Elhabashy ◽  
Ishaan Gupta ◽  
...  

SARS-CoV-2 continues to develop new, increasingly infectious variants, such as delta and omicron. Here, we evaluate the efficacy of the Abbott BinaxNOW Rapid Antigen Test against the gold standard of Reverse Transcription Polymerase Chain Reaction (RT-PCR) in 1054 pediatric participants presenting to a state-owned high-volume Coronavirus Disease 2019 (COVID-19) testing site. During the testing period, the delta variant was predominant. Prior to sample collection, symptomatic and exposure status was collected for all participants based on Centers for Disease Control (CDC) criteria. RT-PCR results demonstrated an overall prevalence rate of 5.2%. For all participants, the sensitivity of the rapid antigen tests was 92.7% (95% CI 82.4% - 98.0%) and specificity was 98.0% (95% CI 97.0%-98.8%). For symptomatic participants, the sensitivity was 92.3% (95% CI 74.9% - 99.1%), specificity was 96.6% (95% CI 93.6%- 98.4%), positive predictive value (PPV) was 72.7% (95% CI 54.5% - 86.7%) and negative predictive value (NPV) was 99.2% (95% CI 98.2% - 100%). Among asymptomatic participants, the sensitivity was 92.6% (95% CI 75.7% - 99.1%), specificity was 98.6% (95% CI 97.5% - 99.3%) the PPV was 71.4% (95% CI 53.7% - 85.4%) and the NPV was 99.7% (95% CI 99.0% - 100%). Our reported sensitivity and NPV are higher than other pediatric studies, but specificity and PPV are lower. Importance Children are especially impacted by the disease and its ability to disrupt educational opportunities. Although vaccinations have been approved for children 5 years and older, many children remain unvaccinated. Widespread testing may improve the ability for children to remain in in-person activities, minimizing absences from school and extracurriculars. Highly accurate rapid antigen tests may be vital to containing future COVID-19 waves while mitigating detrimental effects.


2021 ◽  
Author(s):  
Nira R. Pollock ◽  
Jesica R. Jacobs ◽  
Kristine Tran ◽  
Amber Cranston ◽  
Sita Smith ◽  
...  

AbstractBackgroundRapid diagnostic tests (RDTs) for SARS-CoV-2 antigens (Ag) that can be performed at point-of-care (POC) can supplement molecular testing and help mitigate the COVID-19 pandemic. Deployment of an Ag RDT requires an understanding of its operational and performance characteristics under real-world conditions and in relevant subpopulations. We evaluated the Abbott BinaxNOW™ COVID-19 Ag Card in a high-throughput, drive-through, free community testing site in Massachusetts (MA) using anterior nasal (AN) swab RT-PCR for clinical testing.MethodsIndividuals presenting for molecular testing in two of seven lanes were offered the opportunity to also receive BinaxNOW testing. Dual AN swabs were collected from symptomatic and asymptomatic children (≤ 18 years) and adults. BinaxNOW testing was performed in a testing pod with temperature/humidity monitoring. One individual performed testing and official result reporting for each test, but most tests had a second independent reading to assess inter-operator agreement. Positive BinaxNOW results were scored as faint, medium, or strong. Positive BinaxNOW results were reported to patients by phone and they were instructed to isolate pending RT-PCR results. The paired RT-PCR result was the reference for sensitivity and specificity calculations.ResultsOf 2482 participants, 1380 adults and 928 children had paired RT-PCR/BinaxNOW results and complete symptom data. 974/1380 (71%) adults and 829/928 (89%) children were asymptomatic. BinaxNOW had 96.5% (95% confidence interval [CI] 90.0-99.3) sensitivity and 100% (98.6-100.0) specificity in adults within 7 days of symptoms, and 84.6% (65.1-95.6) sensitivity and 100% (94.5-100.0) specificity in children within 7 days of symptoms. Sensitivity and specificity in asymptomatic adults were 70.2% (56.6-81.6) and 99.6% (98.9-99.9), respectively, and in asymptomatic children were 65.4% (55.6-74.4) and 99.0% (98.0-99.6), respectively. By cycle threshold (Ct) value cutoff, sensitivity in all subgroups combined (n=292 RT-PCR-positive individuals) was 99.3% with Ct ≤25, 95.8% with ≤30, and 81.2% with ≤35. Twelve false positive BinaxNOW results (out of 2308 tests) were observed; in all twelve, the test bands were faint but otherwise normal, and were noted by both readers. One invalid BinaxNOW result was identified. Inter-operator agreement (positive versus negative BinaxNOW result) was 100% (n = 2230/2230 double reads). Each operator was able to process 20 RDTs per hour. In a separate set of 30 specimens (from individuals with symptoms ≤7 days) run at temperatures below the manufacturer’s recommended range (46-58.5°F), sensitivity was 66.7% and specificity 95.2%.ConclusionsBinaxNOW had very high specificity in both adults and children and very high sensitivity in newly symptomatic adults. Overall, 95.8% sensitivity was observed with Ct ≤ 30. These data support public health recommendations for use of the BinaxNOW test in adults with symptoms for ≤7 days without RT-PCR confirmation. Excellent inter-operator agreement indicates that an individual can perform and read the BinaxNOW test alone. A skilled laboratorian can perform and read 20 tests per hour. Careful attention to temperature is critical.


2020 ◽  
Author(s):  
Sebastian Hoehl ◽  
Barbara Schenk ◽  
Olga Rudych ◽  
Stephan Göttig ◽  
Ivo Foppa ◽  
...  

AbstractBackgroundRapid antigen tests for SARS-CoV-2 became available recently, offering an opportunity to vastly increase testing capacities. Antigen tests offer lower sensitivity than the gold standard, RT-PCR, but rapid sample-to-answer time. High-frequency testing with an antigen test may offset the lower sensitivity, and testing can be done with at-home collection of samples, offering potential benefit in screening efforts. In this study, we set out to evaluate the practical application of self-performed high-frequency antigen test in a school setting.MethodA total of 711 teachers from 86 schools were enrolled in a seven-week study. After instruction, participants tested themselves every 48 hours at home with a rapid antigen test for SARS-CoV-2 (target: nucleocapsid protein) in a self-collected anterior nasal swab. Positive results in the antigen test were confirmed via RT-PCR from the same sample that had been determined to be positive by the study participant. A questionnaire was given to all participants to evaluate whether the test failed to detect infection.Findings10 836 tests from 602 teachers were recorded and analyzed. A total of five confirmed cases of viral shedding of SARS-CoV-2 was detected by use of the antigen test. One study participant with a SARS-CoV-2 infection was presymptomatic and four were mildly symptomatic at the time of the antigen test. Sixteen false positive antigen tests (0.15% of all tests) were reported, predominantly when the local incidence in the general population was low. In four cases, the study participant reported that a PCR had detected a SARS-CoV-2 infection, but the antigen test was negative, indicating a false negative result.InterpretationHigh-frequency, self-performed rapid antigen tests can detect individuals with a SARS-CoV-2 infection, and therefore potentially reduce transmissions. Testing may be most beneficial when applied during high local incidence of SARS-CoV-2 infections and when mild or atypical symptoms are present. To avoid a high rate of false positive results, a test with optimized specificity should be used.FundingThe study was commissioned and funded by the Hessian Ministry of Education and the Hessian Ministry of Integration and Social Affairs.


Author(s):  
Olivia Almendares ◽  
Jessica L. Prince-Guerra ◽  
Leisha D. Nolen ◽  
Jayleen K.L. Gunn ◽  
Ariella P. Dale ◽  
...  

Point-of-care antigen tests are an important tool for SARS-CoV-2 detection. Antigen tests are less sensitive than real-time reverse-transcriptase PCR (rRT-PCR). Data on the performance of the BinaxNOW antigen test compared to rRT-PCR and viral culture by symptom and known exposure status, timing during disease or exposure period and demographic variables are limited. During November 3 rd -17 th , 2020, we collected paired upper respiratory swab specimens to test for SARS-CoV-2 by rRT-PCR and Abbott BinaxNOW (BinaxNOW) antigen test at two community testing sites in Pima County, Arizona. We administered a questionnaire to capture symptoms, known exposure status and previous SARS-CoV-2 test results. Specimens positive by either test were analyzed by viral culture. Previously we showed overall BinaxNOW sensitivity was 52.5%. Here we showed BinaxNOW sensitivity increased to 65.7% among currently symptomatic individuals reporting a known exposure. BinaxNOW sensitivity was lower among participants with a known exposure and previously symptomatic (32.4%) or never symptomatic (47.1%) within 14 days of testing. Sensitivity was 71.1% in participants within a week of symptom onset. In participants with a known exposure, sensitivity was highest 8-10 days post-exposure (75%). The positive predictive value for recovery of virus in cell culture was 56.7% for BinaxNOW-positive and 35.4% for rRT-PCR-positive specimens. Result reporting time was 2.5 hours for BinaxNOW and 26 hours for rRT-PCR. Point-of-care antigen tests have a shorter turn-around time compared to laboratory-based nucleic acid amplification tests, which allows for more rapid identification of infected individuals. Antigen test sensitivity limitations are important to consider when developing a testing program.


Sign in / Sign up

Export Citation Format

Share Document