Uniform field breakdown of fluorocarbons and other gases

Author(s):  
G. Olivier ◽  
G. Daigneault ◽  
Y. Gervais
Keyword(s):  
Author(s):  
A. V. Crewe ◽  
M. Isaacson ◽  
D. Johnson

A double focusing magnetic spectrometer has been constructed for use with a field emission electron gun scanning microscope in order to study the electron energy loss mechanism in thin specimens. It is of the uniform field sector type with curved pole pieces. The shape of the pole pieces is determined by requiring that all particles be focused to a point at the image slit (point 1). The resultant shape gives perfect focusing in the median plane (Fig. 1) and first order focusing in the vertical plane (Fig. 2).


Author(s):  
G. F. Rempfer

In photoelectron microscopy (PEM), also called photoemission electron microscopy (PEEM), the image is formed by electrons which have been liberated from the specimen by ultraviolet light. The electrons are accelerated by an electric field before being imaged by an electron lens system. The specimen is supported on a planar electrode (or the electrode itself may be the specimen), and the accelerating field is applied between the specimen, which serves as the cathode, and an anode. The accelerating field is essentially uniform except for microfields near the surface of the specimen and a diverging field near the anode aperture. The uniform field forms a virtual image of the specimen (virtual specimen) at unit lateral magnification, approximately twice as far from the anode as is the specimen. The diverging field at the anode aperture in turn forms a virtual image of the virtual specimen at magnification 2/3, at a distance from the anode of 4/3 the specimen distance. This demagnified virtual image is the object for the objective stage of the lens system.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 19-29
Author(s):  
Shuting Ren ◽  
Yong Li ◽  
Bei Yan ◽  
Jinhua Hu ◽  
Ilham Mukriz Zainal Abidin ◽  
...  

Structures of nonmagnetic materials are broadly used in engineering fields such as aerospace, energy, etc. Due to corrosive and hostile environments, they are vulnerable to the Subsurface Pitting Corrosion (SPC) leading to structural failure. Therefore, it is imperative to conduct periodical inspection and comprehensive evaluation of SPC using reliable nondestructive evaluation techniques. Extended from the conventional Pulsed eddy current method (PEC), Gradient-field Pulsed Eddy Current technique (GPEC) has been proposed and found to be advantageous over PEC in terms of enhanced inspection sensitivity and accuracy in evaluation and imaging of subsurface defects in nonmagnetic conductors. In this paper two GPEC probes for uniform field excitation are intensively analyzed and compared. Their capabilities in SPC evaluation and imaging are explored through simulations and experiments. The optimal position for deployment of the magnetic field sensor is determined by scrutinizing the field uniformity and inspection sensitivity to SPC based on finite element simulations. After the optimal probe structure is chosen, quantitative evaluation and imaging of SPC are investigated. Signal/image processing algorithms for SPC evaluation are proposed. Through simulations and experiments, it has been found that the T-shaped probe together with the proposed processing algorithms is advantageous and preferable for profile recognition and depth evaluation of SPC.


Author(s):  
Б. Дивинский ◽  
B. Divinskiy ◽  
И. Грюне ◽  
I. Gryune ◽  
Р. Косьян ◽  
...  

Acoustic methods belong to contactless measurement means, possess high spatial and time resolution. Thus, the use of multifrequency allows directly profile both concentration and granulometric structure of the suspended substances. In 2008 in the Big Wave Flume (Hanover, Germany) by efforts of the Russian and German scientists there have been carried out the experiment on studying the bottom material suspension laws under the influence of irregular waves. The Aquascat 1000 acoustic back scattering sensor (ABS) manufactured by British company Aquatec (www.aquatecsubsea.com), equipped by a three-frequency transmitter with frequencies 1,0, 2,0 and 3,84 MHz, has been set on distance of 0,75 m from the bottom and 111 m from wave generator at the total depth of 3,2 m. Several dozen series of measurements at various parameters of surface waves have been carried out. The general picture of suspension is so that the external dynamic influence (currents, wave movements, turbulence, gravitation forces) creates a non-uniform field (gradient) of the suspended particles and in most cases due to this the average size of particles undergoes to the spatial-time variations. For this reason while defining the mass concentration of suspended sediment, using the single frequency transmitter there is necessity for numerous definition of the suspension granulometric structure what by isn’t always possible. If two and more frequencies are used the observed results comparison can give the information on average diameters of particles and on that basis the calculation of suspended sediment concentration is possibleLet's emphasize the basic advantages of back scattering acoustic gauges usage: – Obtaining the particles sizes and concentration distribution profiles is possible; – The initial granulometric structure of bottom sediments can be unknown (at use of several frequencies). The following can be referred to some lacks of the device: – The system should be calibrated in laboratory conditions; – In a positive feedback conditions the iterative computing process can converge to zero or to infinity. In this case experiments with a variation of carrier frequencies chosen for the analysis allow partially solve the problem (say experiments with different frequencies pairs, as 2/1 of MHz or 4/2 MHz).


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Tatiana I. Becker ◽  
Yuriy L. Raikher ◽  
Oleg V. Stolbov ◽  
Valter Böhm ◽  
Klaus Zimmermann

Abstract Magnetoactive elastomers (MAEs) are a special type of smart materials consisting of an elastic matrix with embedded microsized particles that are made of ferromagnetic materials with high or low coercivity. Due to their composition, such elastomers possess unique magnetic field-dependent material properties. The present paper compiles the results of investigations on MAEs towards an approach of their potential application as vibrating sensor elements with adaptable sensitivity. Starting with the model-based and experimental studies of the free vibrational behavior displayed by cantilevers made of MAEs, it is shown that the first bending eigenfrequency of the cantilevers depends strongly on the strength of an applied uniform magnetic field. The investigations of the forced vibration response of MAE beams subjected to in-plane kinematic excitation confirm the possibility of active magnetic control of the amplitude-frequency characteristics. With change of the uniform field strength, the MAE beam reveals different steady-state responses for the same excitation, and the resonance may occur at various ranges of the excitation frequency. Nonlinear dependencies of the amplification ratio on the excitation frequency are obtained for different magnitudes of the applied field. Furthermore, it is shown that the steady-state vibrations of MAE beams can be detected based on the magnetic field distortion. The field difference, which is measured simultaneously on the sides of a vibrating MAE beam, provides a signal with the same frequency as the excitation and an amplitude proportional to the amplitude of resulting vibrations. The presented prototype of the MAE-based vibrating unit with the field-controlled “configuration” can be implemented for realization of acceleration sensor systems with adaptable sensitivity. The ongoing research on MAEs is oriented to the use of other geometrical forms along with beams, e.g. two-dimensional structures such as membranes.


Sign in / Sign up

Export Citation Format

Share Document