Study on the Influence Law of Friction-Thermal Interaction on Coated Surface

Author(s):  
Zhihua Sha ◽  
Shangnan Sun ◽  
Qiang Hao ◽  
Jian Yin ◽  
Yu Liu ◽  
...  
1995 ◽  
Vol 73 (05) ◽  
pp. 850-856 ◽  
Author(s):  
F D Rubens ◽  
D W Perry ◽  
M W C Hatton ◽  
P D Bishop ◽  
M A Packham ◽  
...  

SummaryPlatelet accumulation on small- and medium-calibre vascular grafts plays a significant role in graft occlusion. We examined platelet accumulation on the surface of fibrin-coated polyethylene tubing (internal diameter 0.17 cm) during 10 min of flow (l0ml/min) at high wall shear rate (764 s-1). Washed platelets labelled with 51Cr were resuspended in Tyrode solution containing albumin, apyrase and red blood cells (hematocrit 40%). When the thrombin that was used to form the fibrin-coated surface was inactivated with FPRCH2C1 before perfusion of the tubes with the platelet:red blood cell suspension, the accumulation of platelets was 59,840 ± 27,960 platelets per mm2, whereas accumulation on fibrin with residual active thrombin was 316,750 ± 32,560 platelets per mm2 (n = 4). When the fibrin on the surface was cross-linked by including recombinant factor XIII (rFXIII) in the fibrinogen solution used to prepare the fibrin-coated surface, platelet accumulation, after thrombin neutralization, was reduced by the cross-linking from 46,974 ± 9702 to 36,818 ± 7964 platelets per mm2 (n = 12, p <0.01). Platelet accumulation on tubes coated with D-dimer was ten times less than on tubes coated with D-domain; this finding also supports the observation that cross-linking of fibrin with the formation of γ-γ dimers reduces platelet accumulation on the fibrin-coated surface. Thrombin-activated platelets themselves were shown to cross-link fibrin when they had adhered to it during perfusion, or in a static system in which thrombin was used to form clots from FXIII-free fibrinogen in the presence of platelets. Thus, cross-linking of fibrin by FXIII in plasma or from platelets probably decreases the reactivity of the fibrin-containing thrombi to platelets by altering the lysine residue at or near the platelet-binding site of each of the γ-chains of the fibrinogen which was converted into the fibrin of these thrombi.


2006 ◽  
Vol 37 (5) ◽  
pp. 459-466
Author(s):  
B. I. Zyskin ◽  
S. S. Skachkova ◽  
K. V. Zaitsev ◽  
B. V. Berg ◽  
T. F. Bogatova ◽  
...  
Keyword(s):  

2020 ◽  
Vol 20 (6) ◽  
pp. 1-11
Author(s):  
P. V. Bogorodskiy ◽  
N. E. Demidov ◽  
K. V. Filchuk ◽  
A. V. Marchenko ◽  
E. G. Morozov ◽  
...  

Pharmaceutics ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 724
Author(s):  
Amilton Iatecola ◽  
Guilherme Arthur Longhitano ◽  
Luiz Henrique Martinez Antunes ◽  
André Luiz Jardini ◽  
Emilio de Castro Miguel ◽  
...  

Cobalt-base alloys (Co-Cr-Mo) are widely employed in dentistry and orthopedic implants due to their biocompatibility, high mechanical strength and wear resistance. The osseointegration of implants can be improved by surface modification techniques. However, complex geometries obtained by additive manufacturing (AM) limits the efficiency of mechanical-based surface modification techniques. Therefore, plasma immersion ion implantation (PIII) is the best alternative, creating nanotopography even in complex structures. In the present study, we report the osseointegration results in three conditions of the additively manufactured Co-Cr-Mo alloy: (i) as-built, (ii) after PIII, and (iii) coated with titanium (Ti) followed by PIII. The metallic samples were designed with a solid half and a porous half to observe the bone ingrowth in different surfaces. Our results revealed that all conditions presented cortical bone formation. The titanium-coated sample exhibited the best biomechanical results, which was attributed to the higher bone ingrowth percentage with almost all medullary canals filled with neoformed bone and the pores of the implant filled and surrounded by bone ingrowth. It was concluded that the metal alloys produced for AM are biocompatible and stimulate bone neoformation, especially when the Co-28Cr-6Mo alloy with a Ti-coated surface, nanostructured and anodized by PIII is used, whose technology has been shown to increase the osseointegration capacity of this implant.


Processes ◽  
2021 ◽  
Vol 9 (1) ◽  
pp. 99
Author(s):  
Sun-Woo Yi ◽  
In-Keun Yu ◽  
Woon-Jung Kim ◽  
Seong-Ho Choi

In this study, we coated the surface of glass slides with nanoprotrusion, nanoparticles, and nanofilm structures by one-step plasma deposition of three vinyl monomers. Three functional vinyl monomers with symmetrical polarity sites were used: methyl methacrylate (MMA), trifluoro methylmethacrylate (TFMA), and trimethylsilyl methyl methacrylate (TSMA). The TSMA/MMA (80/20, mol-%) nanoprotrusion-coated surface of slide glass was superhydrophobic, with a 153° contact angle. We also evaluated the transmittance (%) of the slide glass with nanoprotrusions in the infrared (IR) (940 nm), ultraviolet (365 nm) and visible light (380–700 nm) regions. The obtained nanoprotrusion structure surface of slide glass created by plasma deposition transmits more than 90% of visible light.


1998 ◽  
Vol 4 (S2) ◽  
pp. 860-861 ◽  
Author(s):  
A. Ramirez de Arellano López ◽  
W.-A. Chiou ◽  
K. T. Faber

The results of TEM analyses of materials are critically dependent on the quality of the sample prepared. Although numerous techniques have been developed in the last two decades, differential thinning of inhomogeneous materials remains a serious problem. Recently, focused ion beam (FIB) technique has been introduced for cross-sectional sample preparation for TEM and SEM.A novel system for depositing a fine-grain (∼ 200 nm) ceramic coating on a metal surface via a patent pending Small-Particle Plasma Spray (SPPS) technique has been developed at the Basic Industry Research Laboratory of Northwestern University. To understand the properties of the coated surface, the ceramic/metal interface and the microstructure of the ceramic coating must be investigated. This paper presents a comparison of the microstructure of an A12O3 coating on a mild steel substrate prepared using conventional and FEB techniques.


1988 ◽  
Vol 110 (2) ◽  
pp. 222-227 ◽  
Author(s):  
F. D. Ju ◽  
J. C. Liu

This investigation considers the thermo-mechanical effects of an asperity traversing at a high speed over a semi-infinite medium with a thin, hard coated surface. The general analytical solution of the temperature field and the thermal stress state are obtained and expressed in Fourier transform space. The analysis emphasizes the heating effect of the friction force, which leads to the initiation of the thermo-mechanical cracking or “heat-checking,” in the coating layer, the substrate, or their interface. For hard coated layers, the initiation of a crack will occur either in the coating layer, the substrate or the interface depending on the relative properties of the coating and the substrate and their bonding strength.


Sign in / Sign up

Export Citation Format

Share Document