Influence of the 50 Hz magnetic field on the body color and the amount of urine of goldfish

Author(s):  
Y. Sawaguchi ◽  
K. Kimura ◽  
K. Misawa ◽  
J. Arisawa
Keyword(s):  
The Body ◽  
Author(s):  
Zulkarnay Zakaria ◽  
Mohd Fahajumi Jumaah ◽  
Mohd Saiful Badri Mansor ◽  
Khairi Mat Daud ◽  
Mohd Hafiz Fazalul Rahiman ◽  
...  

Terapi merupakan antara teknik perubatan tertua dalam mengekalkan kesihatan badan terutama daripada aliran darah yang tidak baik, strok dan beberapa penyakit yang lain. Teknik ini termasuklah akupuntur, guasa dan juga urutan. Terdapat juga teknik terapi moden seperti terapi warna, terapi ozon, terapi dadah dan banyak lagi. Kertas kajian ini akan mengetengahkan penjana terapi elektromagnet, satu alat yang mempunyai potensi aplikasi terapi dalam bidang perubatan. Alat ini menghasilkan medan magnet berfrekuensi sederhana sebagai sumber terapi. Perkakasan yang berskala kecil berfrekuensi sederhana dan berkos rendah ini telah dibangunkan dan telah diuji pada tisu biologi bagi mengukur tahap ketembusan medan magnet. Ujian ini telah membuktikan bahawa medan magnet yang telah dihasilkan mampu menembusi tisu lembut bersaiz sehingga 2 cm dengan jarak 7 cm daripada sumber. Kebolehan penembusan sistem ini terhadap tisu lembut memberikan peluang yang cerah kepada kajian ini memandangkan medan magnet telah menunjukkan potensi sebagai sebahagian daripada terapi untuk memulihkan migraine, strok, kekejangan dan beberapa yang lain selain boleh diaplikasikan dalam pengimejan tomografi induksi magnet. Kata kunci: Terapi elektromagnet, medan magnet, penembusan, tisu lembut, aplikasi perubatan Therapy is among the oldest medication technique in maintaining the health of the body especially from bad blood circulation, stroke and several others. This technique includes acupuncture, guasa and also massage. There are also modern therapy techniques like colour therapy, water therapy, ozone therapy, drug therapy and others. This paper will highlight electromagnetic therapy generator, a device which has the potential of therapy application in medical field. This device produce medium frequency magnetic field as a therapy source. This small scale medium frequency and low cost hardware that has been developed was tested on the biological tissue for the purpose of measuring the magnetic field penetration. The testing has proven that the generated magnetic field is able to penetrate the soft tissue up to 2 cm with distance from the source up to 7 cm. The capability of the system penetrations through the soft tissues provide the bright future of this research since magnetic field have shown the potential as being part of the therapy for curing migraine, stroke, cramp and several others besides the application in the magnetic induction tomography imaging. Key words: Electromagnetic therapy, magnetic field, penetration, soft tissue; medical applications


2003 ◽  
Vol 13 (12) ◽  
pp. 3783-3789 ◽  
Author(s):  
F. E. SMITH ◽  
P. LANGLEY ◽  
L. TRAHMS ◽  
U. STEINHOFF ◽  
J. P. BOURKE ◽  
...  

Multichannel magnetocardiography measures the magnetic field distribution of the human heart noninvasively from many sites over the body surface. Multichannel magnetocardiogram (MCG) analysis enables regional temporal differences in the distribution of cardiac magnetic field strength during depolarization and repolarization to be identified, allowing estimation of the global and local inhomogeneity of the cardiac activation process. The aim of this study was to compare the spatial distribution of cardiac magnetic field strength during ventricular depolarization and repolarization in both normal subjects and patients with cardiac abnormalities, obtaining amplitude measurements by magnetocardiography. MCGs were recorded at 49 sites over the heart from three normal subjects and two patients with inverted T-wave conditions. The magnetic field intensity during depolarization and repolarization was measured automatically for each channel and displayed spatially as contour maps. A Pearson correlation was used to determine the spatial relationship between the variables. For normal subjects, magnetic field strength maps during depolarization (R-wave) showed two asymmetric regions of magnetic field strength with a high positive value in the lower half of the chest and a high negative value above this. The regions of high R-wave amplitude corresponded spatially to concentrated asymmetric regions of high magnetic field strength during repolarization (T-wave). Pearson-r correlation coefficients of 0.7 (p<0.01), 0.8 (p<0.01) and 0.9 (p<0.01) were obtained from this analysis for the three normal subjects. A negative correlation coefficient of -0.7 (p<0.01) was obtained for one of the subjects with inverted T-wave abnormalities, suggesting similar but inverted magnetic field and current distributions to normal subjects. Even with the high correlation values in these four subjects, the MCG was able to identify differences in the distribution of magnetic field strength, with a shift in the T-wave relative to the R-wave. The measurement of cardiac magnetic field distribution during depolarization and repolarization of normal subjects and patients with clinical abnormalities should enable the improvement of theoretical models for the explanation of the cardiac depolarization and repolarization processes.


Author(s):  
K. Mendelssohn ◽  
J. D. Babbitt ◽  
Frederick Alexander Lindemann

Until a year ago it was generally accepted that if a body is made supraconducting while in a magnetic field the lines of magnetic force were "frozen in," i. e ., whatever lines of force passed through the body at the time when it became supraconducting remained there afterwards, unaffected by any change in the external field, so long as the body was supraconducting. Meissner and Ochsenfeld, however, showed that this supposition was not true. They measured field strengths in the immediate neighbourhood of cylinders which had been cooled to supraconductivity in an external magnetic field, and found that the field of force was then of the same nature as that to be expected in the neighbourhood of perfectly diamagnetic bodies. Thus it appeared that when a body becomes supraconducting in a magnetic field the lines of force are all pressed out of the body, and the induction inside the body falls to zero. At the same time, however, these authors report on another experiment, the result of which appears to us not entirely in accordance with the assumption that the induction in the whole body became zero. They measured the field strengths inside and outside a hollow cylinder, after it had become supraconducting in a field perpendicular to its axis, and found again that the field strength outside was as if the cylinder were almost perfectly diamagnetic, but the field inside was appreciably the same as if the cylinder were non-supraconducting. We therefore made a number of experiments, hoping to find out more exactly the nature of the phenomenon.


Sociobiology ◽  
2021 ◽  
Vol 68 (1) ◽  
pp. 5188
Author(s):  
Márlon César Pereira ◽  
Maria da Graça Cardoso Pereira-Bomfim ◽  
Ingrid De Carvaho Guimarães ◽  
Candida Anitta Pereira Rodrigues ◽  
Jilder Peña Serna ◽  
...  

The aim of the present paper is to study magnetosensibility and to seek for magnetic nanoparticles in ants. The social insects, by living in colonies, developed very efficient methods of nestmate recognition, being less tolerant towards individuals from other colonies. Therefore, any kind of strange behavior between nestmates and/or conspecifics, besides those present in their own behavioral repertoire, is not expected. The behavior study in the present paper analyze whether changes in the intensity of applied magnetic fields on Ectatomma brunneun (Smith) ants can cause changes in the normal pattern of interaction between conspecifics. A pair of coils generating a magnetic field was used to change the whole local geomagnetic field. Magnetometry studies were done on abdomens and head + antennae using a SQUID magnetometer. The results show that changes in the geomagnetic field affect the usual pattern of interactions between workers from different colonies. The magnetometry results show that abdomens present superparamagnetic nanoparticles and heads present magnetic single domain nanoparticles. Behavior experiments show for the first time that Ectatomma brunneun ants are magnetosensible. The change in nestmate recognition of Ectatomma ants observed while a magnetic field is applied can be associated to some kind of disturbance in a magnetosensor presented in the body based on magnetic nanoparticles.


2021 ◽  
Vol 11 ◽  
Author(s):  
Sarah Kraus ◽  
Raz Khandadash ◽  
Raphael Hof ◽  
Abraham Nyska ◽  
Ekaterina Sigalov ◽  
...  

Sarah Nanoparticles (SaNPs) are unique multicore iron oxide-based nanoparticles, developed for the treatment of advanced cancer, following standard care, through the selective delivery of thermal energy to malignant cells upon exposure to an alternating magnetic field. For their therapeutic effect, SaNPs need to accumulate in the tumor. Since the potential accumulation and associated toxicity in normal tissues are an important risk consideration, biodistribution and toxicity were assessed in naïve BALB/c mice. Therapeutic efficacy and the effect on survival were investigated in the 4T1 murine model of metastatic breast cancer. Toxicity evaluation at various timepoints did not reveal any abnormal clinical signs, evidence of alterations in organ function, nor histopathologic adverse target organ toxicity, even after a follow up period of 25 weeks, confirming the safety of SaNP use. The biodistribution evaluation, following SaNP administration, indicated that SaNPs accumulate mainly in the liver and spleen. A comprehensive pharmacokinetics evaluation, demonstrated that the total percentage of SaNPs that accumulated in the blood and vital organs was ~78%, 46%, and 36% after 4, 13, and 25 weeks, respectively, suggesting a time-dependent clearance from the body. Efficacy studies in mice bearing 4T1 metastatic tumors revealed a 49.6% and 70% reduction in the number of lung metastases and their relative size, respectively, in treated vs. control mice, accompanied by a decrease in tumor cell viability in response to treatment. Moreover, SaNP treatment followed by alternating magnetic field exposure significantly improved the survival rate of treated mice compared to the controls. The median survival time was 29 ± 3.8 days in the treated group vs. 21.6 ± 4.9 days in the control, p-value 0.029. These assessments open new avenues for generating SaNPs and alternating magnetic field application as a potential novel therapeutic modality for metastatic cancer patients.


2018 ◽  
Vol 24 (3) ◽  
pp. 738-747
Author(s):  
M Šilhavý

The recent renewal of interest in nonlinear electromagnetoelastic interactions comes from the technological importance of electro- or magnetosensitive elastomers, smart materials whose mechanical properties change instantly on the application of an electric or magnetic field. We consider materials with free energy functions of the form [Formula: see text], where F is the deformation gradient, d is the electric displacement, and b is the magnetic induction. It was recently shown by the author that such an energy function is polyconvex if and only if it is of the form [Formula: see text] where [Formula: see text] is a convex function (of 31 scalar variables). Moreover, an existence theorem was proved for the equilibrium solution for a system consisting of a polyconvex electromagnetoelastic solid plus the vacuum electromagnetic field outside the body. The condition (8), is not just the combination of Ball’s polyconvexity of elastomers [Formula: see text] with the convexity in the electromagnetic variables. The differential constraints div [Formula: see text], div [Formula: see text] allow for the cross mechanical–electric and mechanical–magnetic terms Fd and Fb which substantially enlarge the class of energies covered by the theory. The result (*), applies to a material of any symmetry; this paper analyzes the condition in the case of isotropic materials. A broad sufficient condition for the polyconvexity is given in that case. Further, it is shown that the commonly used isotropic electroelastic or magnetoelastic invariants are polyconvex except for the biquadratic ones; the paper explicitly determines their quasiconvex envelopes and shows that they are polyconvex.


Author(s):  
Hitomi Seike ◽  
Shinji Nagata

Abstract Body-color in insects changes according to the living environment and physiological stresses possibly involved in endocrine factors. To date, three predominant bioactive peptides, Corazonin, Elevenin, and pigment-dispersing factor (PDF) have been illuminated to be involved in the body-color in insects and crustaceans. Here, we examined the possibilities that these three factors would contribute to body-color changes via melanization in the two-spotted cricket, Gryllus bimaculatus, whose body color changes according to population density drastically. Quantitative analyses revealed that the higher transcriptional levels of Corazonin and Elevenin in the crowded-conditioned crickets, whereas the transcriptional level of PDF was higher in the isolated-conditioned crickets. However, the body color was not changed by knockdown of Corazonin, Elevenin, and PDF by RNA interference. The present data indicated that coloration mechanisms in G. bimaculatus is differently controlled from the previous observation in Locusta migratoria, a closely related orthopteran species.


Nanomaterials ◽  
2019 ◽  
Vol 9 (12) ◽  
pp. 1713 ◽  
Author(s):  
Niklas Lucht ◽  
Ralf P. Friedrich ◽  
Sebastian Draack ◽  
Christoph Alexiou ◽  
Thilo Viereck ◽  
...  

Magnetic hyperthermia is a technique that describes the heating of material through an external magnetic field. Classic hyperthermia is a medical condition where the human body overheats, being usually triggered by a heat stroke, which can lead to severe damage to organs and tissue due to the denaturation of cells. In modern medicine, hyperthermia can be deliberately induced to specified parts of the body to destroy malignant cells. Magnetic hyperthermia describes the way that this overheating is induced and it has the inherent advantage of being a minimal invasive method when compared to traditional surgery methods. This work presents a particle system that offers huge potential for hyperthermia treatments, given its good loss value, i.e., the particles dissipate a lot of heat to their surroundings when treated with an ac magnetic field. The measurements were performed in a low-cost custom hyperthermia setup. Additional toxicity assessments on Jurkat cells show a very low short-term toxicity on the particles and a moderate low toxicity after two days due to the prevalent health concerns towards nanoparticles in organisms.


Sign in / Sign up

Export Citation Format

Share Document