Impacts of Systematic Errors on Topographic Parameter Estimation in Multitemporal InSAR: A Quantitative Description

Author(s):  
Hongyu Liu ◽  
Lei Zhang ◽  
Bofeng Li ◽  
Jun Hu
Author(s):  
Monika Wanat ◽  
Maura Malinska ◽  
Matthias J. Gutmann ◽  
Richard I. Cooper ◽  
Krzysztof Wozniak

The Independent Atom Model (IAM) of electron density is used in routine X-ray data analysis. However, this model does not give a quantitative description of the electron-density distribution. A better model that allows for modelling of aspherical charge density deformations is introduced by the Hansen–Coppens variant of the multipole model of electron density. However, the application of this model requires crystals of excellent quality and high-resolution XRD data which are quite often difficult criteria to fulfil. Therefore, Mo Kα and Cu Kα data of three model compounds (tricyclic imide, xylitol and methyluracil) were refined using IAM and new methods which enabled the refinement and reconstruction of charge density based on the Cu Kα data. These methods were the Bond-Oriented Deformation Density (BODD) model, Hirshfeld Atom Refinement (HAR) and the Transferable Aspherical Atom Model (TAAM). The final results were compared to the model obtained from neutron diffraction experiments. Our results demonstrated not only that Cu Kα data may be refined using BODD, HAR and TAAM methods, but also revealed systematic errors arising from the use of Cu Kα data. These errors were a result of the limited information in the low-resolution data set that manifested as higher values for the anisotropic displacement parameters (ADPs) and smaller maxima and minima of the residual electron density for the Cu Kα data compared to the Mo Kα data. Notably, these systematic errors were much less significant than those found for the IAM. Therefore, the application of BODD, HAR and TAAM on Cu Kα data has a more significant influence on the final results of refinement than for the Mo Kα data.


2009 ◽  
Vol 6 (6) ◽  
pp. 10447-10477 ◽  
Author(s):  
L. Zhang ◽  
M. Xu ◽  
M. Huang ◽  
G. Yu

Abstract. Modeling ecosystem carbon cycle on the regional and global scales is crucial to the prediction of future global atmospheric CO2 concentration and thus global temperature which features large uncertainties due mainly to the limitations in our knowledge and in the climate and ecosystem models. There is a growing body of research on parameter estimation against available carbon measurements to reduce model prediction uncertainty at regional and global scales. However, the systematic errors with the observation data have rarely been investigated in the optimization procedures in previous studies. In this study, we examined the feasibility of reducing the impact of systematic errors on parameter estimation using normalization methods, and evaluated the effectiveness of three normalization methods (i.e. maximum normalization, min-max normalization, and z-score normalization) on inversing key parameters, for example the maximum carboxylation rate (Vcmax,25) at a reference temperature of 25°C, in a process-based ecosystem model for deciduous needle-leaf forests in northern China constrained by the leaf area index (LAI) data. The LAI data used for parameter estimation were composed of the model output LAI (truth) and various designated systematic errors and random errors. We found that the estimation of Vcmax,25 could be severely biased with the composite LAI if no normalization was taken. Compared with the maximum normalization and the min-max normalization methods, the z-score normalization method was the most robust in reducing the impact of systematic errors on parameter estimation. The most probable values of estimated Vcmax,25 inversed by the z-score normalized LAI data were consistent with the true parameter values as in the model inputs though the estimation uncertainty increased with the magnitudes of random errors in the observations. We concluded that the z-score normalization method should be applied to the observed or measured data to improve model parameter estimation, especially when the potential errors in the constraining (observation) datasets are unknown.


1978 ◽  
Vol 48 ◽  
pp. 7-29
Author(s):  
T. E. Lutz

This review paper deals with the use of statistical methods to evaluate systematic and random errors associated with trigonometric parallaxes. First, systematic errors which arise when using trigonometric parallaxes to calibrate luminosity systems are discussed. Next, determination of the external errors of parallax measurement are reviewed. Observatory corrections are discussed. Schilt’s point, that as the causes of these systematic differences between observatories are not known the computed corrections can not be applied appropriately, is emphasized. However, modern parallax work is sufficiently accurate that it is necessary to determine observatory corrections if full use is to be made of the potential precision of the data. To this end, it is suggested that a prior experimental design is required. Past experience has shown that accidental overlap of observing programs will not suffice to determine observatory corrections which are meaningful.


1988 ◽  
Vol 102 ◽  
pp. 215
Author(s):  
R.M. More ◽  
G.B. Zimmerman ◽  
Z. Zinamon

Autoionization and dielectronic attachment are usually omitted from rate equations for the non–LTE average–atom model, causing systematic errors in predicted ionization states and electronic populations for atoms in hot dense plasmas produced by laser irradiation of solid targets. We formulate a method by which dielectronic recombination can be included in average–atom calculations without conflict with the principle of detailed balance. The essential new feature in this extended average atom model is a treatment of strong correlations of electron populations induced by the dielectronic attachment process.


Author(s):  
N. V. Larcher ◽  
I. G. Solorzano

It is currently well established that, for an Al-Ag alloy quenched from the α phase and aged within the metastable solvus, the aging sequence is: supersaturated α → GP zones → γ’ → γ (Ag2Al). While GP zones and plate-shaped γ’ are metastable phases, continuously distributed in the matrix, formation of the equilibrium phase γ takes place at grain boundaries by discontinuous precipitation (DP). The crystal structure of both γ’ and γ is hep with the following orientation relationship with respect to the fee α matrix: {0001}γ′,γ // {111}α, <1120>γ′,γ, // <110>α.The mechanisms and kinetics of continuous matrix precipitation (CMP) in dilute Al-Ag alloys have been studied in considerable detail. The quantitative description of DP kinetics, however, has received less attention. The present contribution reports the microstructural evolution resulting from aging an Al-Ag alloy with Ag content higher than those previously reported in the literature, focusing the observations of γ' plate-shaped metastable precipitates.


Author(s):  
W.J. de Ruijter ◽  
Sharma Renu

Established methods for measurement of lattice spacings and angles of crystalline materials include x-ray diffraction, microdiffraction and HREM imaging. Structural information from HREM images is normally obtained off-line with the traveling table microscope or by the optical diffractogram technique. We present a new method for precise measurement of lattice vectors from HREM images using an on-line computer connected to the electron microscope. It has already been established that an image of crystalline material can be represented by a finite number of sinusoids. The amplitude and the phase of these sinusoids are affected by the microscope transfer characteristics, which are strongly influenced by the settings of defocus, astigmatism and beam alignment. However, the frequency of each sinusoid is solely a function of overall magnification and periodicities present in the specimen. After proper calibration of the overall magnification, lattice vectors can be measured unambiguously from HREM images.Measurement of lattice vectors is a statistical parameter estimation problem which is similar to amplitude, phase and frequency estimation of sinusoids in 1-dimensional signals as encountered, for example, in radar, sonar and telecommunications. It is important to properly model the observations, the systematic errors and the non-systematic errors. The observations are modelled as a sum of (2-dimensional) sinusoids. In the present study the components of the frequency vector of the sinusoids are the only parameters of interest. Non-systematic errors in recorded electron images are described as white Gaussian noise. The most important systematic error is geometric distortion. Lattice vectors are measured using a two step procedure. First a coarse search is obtained using a Fast Fourier Transform on an image section of interest. Prior to Fourier transformation the image section is multiplied with a window, which gradually falls off to zero at the edges. The user indicates interactively the periodicities of interest by selecting spots in the digital diffractogram. A fine search for each selected frequency is implemented using a bilinear interpolation, which is dependent on the window function. It is possible to refine the estimation even further using a non-linear least squares estimation. The first two steps provide the proper starting values for the numerical minimization (e.g. Gauss-Newton). This third step increases the precision with 30% to the highest theoretically attainable (Cramer and Rao Lower Bound). In the present studies we use a Gatan 622 TV camera attached to the JEM 4000EX electron microscope. Image analysis is implemented on a Micro VAX II computer equipped with a powerful array processor and real time image processing hardware. The typical precision, as defined by the standard deviation of the distribution of measurement errors, is found to be <0.003Å measured on single crystal silicon and <0.02Å measured on small (10-30Å) specimen areas. These values are ×10 times larger than predicted by theory. Furthermore, the measured precision is observed to be independent on signal-to-noise ratio (determined by the number of averaged TV frames). Obviously, the precision is restricted by geometric distortion mainly caused by the TV camera. For this reason, we are replacing the Gatan 622 TV camera with a modern high-grade CCD-based camera system. Such a system not only has negligible geometric distortion, but also high dynamic range (>10,000) and high resolution (1024x1024 pixels). The geometric distortion of the projector lenses can be measured, and corrected through re-sampling of the digitized image.


Sign in / Sign up

Export Citation Format

Share Document