Ortholeg Project - Development of an Active Orthosis Prototype for Lower Limbs

Author(s):  
Marcio V. de Araujo ◽  
Glaumo N. da Silva ◽  
Lennedy C. Soares ◽  
Pablo J. Alsina
Author(s):  
Ivanka Petkova Veneva ◽  
Dimitar Chakarov ◽  
Mihail Tsveov ◽  
Dimitar Stefanov Trifonov ◽  
Evgeni Zlatanov ◽  
...  

Active orthosis (exoskeleton) is an assistive device with a wearable structure, corresponding to the natural motions of the human. This chapter focuses on developing an active/assistive orthosis system (AOS) enhancing movement. The AOS design is inspired by the biological musculoskeletal system of human upper and lower limbs and mimics the muscle-tendon-ligament structure. The exoskeleton structure includes left and right upper limb, left and right lower limb, and central exoskeleton structure for human torso and waist and provides support, balance, and control of different segments of the body. The device was fabricated with light materials and powered by pneumatic artificial muscles that provide more than fifteen degrees of freedom for the different joints. The active orthotic systems (AOS) can operate in three modes: motion tracking system with data exchange with virtual reality; haptic and rehabilitation device; and assistive mode with active orthosis in cases of impaired muscles.


Author(s):  
Ivanka Petkova Veneva ◽  
Dimitar Chakarov ◽  
Mihail Tsveov ◽  
Dimitar Stefanov Trifonov ◽  
Evgeni Zlatanov ◽  
...  

Active orthosis (exoskeleton) is an assistive device with a wearable structure, corresponding to the natural motions of the human. This chapter focuses on developing an active/assistive orthosis system (AOS) enhancing movement. The AOS design is inspired by the biological musculoskeletal system of human upper and lower limbs and mimics the muscle-tendon-ligament structure. The exoskeleton structure includes left and right upper limb, left and right lower limb, and central exoskeleton structure for human torso and waist and provides support, balance, and control of different segments of the body. The device was fabricated with light materials and powered by pneumatic artificial muscles that provide more than fifteen degrees of freedom for the different joints. The active orthotic systems (AOS) can operate in three modes: motion tracking system with data exchange with virtual reality; haptic and rehabilitation device; and assistive mode with active orthosis in cases of impaired muscles.


2018 ◽  
Vol 23 (1) ◽  
pp. 107-120
Author(s):  
V. Musalimov ◽  
Y. Monahov ◽  
M. Tamre ◽  
D. Rõbak ◽  
A. Sivitski ◽  
...  

AbstractThe article discusses motion of a healthy knee joint in the sagittal plane and motion of an injured knee joint supported by an active orthosis. A kinematic scheme of a mechanism for the simulation of a knee joint motion is developed and motion of healthy and injured knee joints are modelled in Matlab. Angles between links, which simulate the femur and tibia are controlled by Simulink block of Model predictive control (MPC). The results of simulation have been compared with several samples of real motion of the human knee joint obtained from motion capture systems. On the basis of these analyses and also of the analysis of the forces in human lower limbs created at motion, an active smart orthosis is developed. The orthosis design was optimized to achieve an energy saving system with sufficient anatomy, necessary reliability, easy exploitation and low cost. With the orthosis it is possible to unload the knee joint, and also partially or fully compensate muscle forces required for the bending of the lower limb.


VASA ◽  
2012 ◽  
Vol 41 (2) ◽  
pp. 132-135 ◽  
Author(s):  
Krohn ◽  
Gebauer ◽  
Hübler ◽  
Beck

The mid-aortic syndrome is an uncommon clinical condition characterized by severe narrowing of the descending aorta, usually with involvement of its renal and visceral branches, presenting with uncontrollably elevated blood pressures of the upper body, renal and cardiac failure, intestinal ischemia, encephalopathy symptoms and claudication of the lower limbs, although clinical presentation is variable. In this article we report the case of an eleven-year-old patient with the initial diagnosis of a mid-aortic syndrome and present the computed tomography angiography pictures and reconstructions before and after surgical therapy.


Phlebologie ◽  
2008 ◽  
Vol 37 (05) ◽  
pp. 247-252 ◽  
Author(s):  
V. S. Brauer ◽  
W. J. Brauer

SummaryPurpose: Comparison of qualitative and quantitative sonography with the lymphoscintigraphic function test and clinical findings in legs. Patients, methods: In 33 patients a lymphoscintigraphic function test of legs combined with measurement of lymph node uptake was performed and subsequently compared with sonography. Sonographic criteria were: Thickness of cutis, thickness of subcutanean fatty tissue and presence of liquid structures or fine disperse tissue structure of lower limbs, foots and toes. Results: In 51 legs uptake values lie in the pathologic area, in four legs in the grey area and in ten legs in the normal area. The cutis thickness in the lower leg shows no significant correlation with the uptake. The determination of the thickness of the subcutanean fatty tissue of the lower leg and of the cutis thickness of the feet turned out to be an unreliable method. In 47% of the medial lower legs and in 57% of the lateral lower legs with clinical lymphoedema sonography is falsely negative. Conclusion: Early lymphoedema is only detectable with the lymphoscintigraphic function test. In the case of clinical lymphoedema clinical examination is more reliable than sonography.


1990 ◽  
Vol 29 (05) ◽  
pp. 215-220 ◽  
Author(s):  
R. Benning ◽  
K. Nagel ◽  
M. Jugenheimer ◽  
S. Fischer ◽  
S. Worthmann ◽  
...  

A new 99mTc-labelled tracer (99mTc-Sestanriibi) was used for the first time to demonstrate the perfusion of the skeletal muscle. In 16 patients with obstructive atherosclerosis of the lower limbs the change of perfusion of thigh and lower leg was studied with SPECT before and after vascular surgery (n = 11) or percutaneous transluminal angioplasty (n = 5). Comparative results of scintigraphic measurements and clinical observations (ancle-arm pressure, treadmill test) in 10 surgical patients (14 operated legs) showed correct positive or negative results in 86% (12/14).


1990 ◽  
Vol 63 (01) ◽  
pp. 076-081 ◽  
Author(s):  
Pascale Gaussem ◽  
Sophie Gandrille ◽  
Pascale Molho-Sabatier ◽  
Loïc Capron ◽  
Jean-Noël Fiessinger ◽  
...  

SummaryUsing a monoclonal antibody-based assay, we measured the fibrin degradation product release in the supernatant of plasma clots obtained before and after venous occlusion (VO) in 30 patients with definite or suspected vascular thrombosis (19 definite and 2 suspected deep vein thrombosis, 6 recurrent superficial thrombophlebitis, 3 arterial occlusions of lower limbs). tPA and PAI-1 concentrations were determined using ELISA assays; the post-occlusion values were corrected for haemoconcentration. The increase in tPA during VO was correlated with haemoconcentration (r = 0.74), but 3 patients had ineffective VO (<2% increase in proteins). The fibrinolytic response to VO was evaluated using the shortening of the time necessary for the release of 200 μg of fibrin degradation products per mg of fibrinogen (Δ T 200). Two among the 27 patients with effective VO were bad responders with a Δ T 200 <3 h (whereas all the others had Δ T 200 >10 h). These patients had respectively a deficient tPA release (Δ tPA = 1 ng/ml) and an elevated PAI-1 level at rest (33 ng/ml). Several other patients were bad responders in terms of tPA release or of shortening of the euglobulin clot lysis time but they had a normal Δ T 200. This plasma clot test reflects the ability of free tPA to bind to fibrin (the amount of which depends on the level of tPA and PAI-1), and may be useful in the diagnosis of a hypofibrinolytic state.


1996 ◽  
Vol 76 (04) ◽  
pp. 518-522 ◽  
Author(s):  
A Elias ◽  
I Aptel ◽  
B Huc ◽  
J J Chale ◽  
F Nguyen ◽  
...  

SummaryThe current D-Dimer ELISA methods provide high sensitivity and negative predictive value for the diagnosis of deep vein thrombosis but these methods are not suitable for emergency or for individual determination. We have evaluated the performance of 3 newly available fast D-Dimer assays (Vidas D-Di, BioMerieux; Instant IA D-Di, Stago; Nycocard D-Dimer, Nycomed) in comparison with 3 classic ELISA methods (Stago, Organon, Behring) and a Latex agglutination technique (Stago). One-hundred-and-seventy-one patients suspected of presenting a first episode of deep vein thrombosis were investigated. A deep vein thrombosis was detected in 75 patients (43.8%) by ultrasonic duplex scanning of the lower limbs; in 11 of them the thrombi were distal and very limited in size (<2 cm). We compared the performance of the tests by calculating their sensitivity, specificity, positive and negative predictive value for different cut-off levels and by calculating the area under ROC curves. The concordance of the different methods was evaluated by calculating the kappa coefficient. The performances of the 3 classic ELISA and of the Vidas D-Di were comparable and kappa coefficients indicated a good concordance between the results provided by these assays. Their sensitivity slightly declined for detection of the very small thrombi. Instant IA D-Di had a non-significantly lower sensitivity and negative predictive value than the 4 previous assays; however its performance was excellent for out-patients. As expected, the Latex assay had too low a sensitivity and negative predictive value to be recommended. In our hands, Nycocard D-Dimer also exhibited low sensitivity and negative predictive value, which were significantly improved when the plasma samples were tested by the manufacturer. Thus significant progress has been made, allowing clinical studies to be planned to compare the safety and cost-effectiveness of D-Dimer strategy to those of the conventional methods for the diagnosis of venous thrombosis.


1980 ◽  
Vol 44 (03) ◽  
pp. 167-167 ◽  
Author(s):  
B Boneu ◽  
P Sie ◽  
C Caranobe ◽  
D Lefebvre ◽  
B Pradere ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document